Background: The accuracy of fitness of any dental casting is imperative for the success of any prosthodontic treatment. From the time that dental casting was first introduced, efforts have been made to produce more accurate and better fitted castings with minimal marginal discrepancy. The aim of this in vitro study was to evaluate the effects of three different investing and burnout techniques on the vertical marginal discrepancies ofceramometalcopings invested with two types of phosphate- bonded investments. Materials and methods: Sixty wax patterns were fabricated on a standardized prepared brass die representing an upper central incisor by the aid of a custom-made split mold. Three different investing and burnout techniques were applied for an Iraqi investment and a commercial type; Group I:Ring investing with conventional burnout technique (RC);Group II: Ringless investing with conventional burnout technique (RLC);Group III: Ring investing with accelerated burnout technique (RA).Twenty wax patterns of each group were divided into two subgroups according to the type of investment material used (10 for each subgroup) represented as (B) for the BellaStar XL and (W) for the WYMvest investments. Complete castings were finished and seated on the metal die. The accuracy of fit of each coping was determined by measuring the vertical marginal discrepancies between the finish line on the metal die and the margins of each coping at four specific reference points on the labial, mesial, palatal, and distal aspects of the die by the aid of a light microscope supplied with a digital camera.The arithmetic mean of each three records was computed and regarded as the amount of the marginal discrepancy of each coping and was used as a unit for the statistical analysis. Results: Mean marginal accuracy for W(RLC)was found to be the least (13.839+4.5724 um) while the highest mean value related to B(RLC) (29.033+2.102 um). In general, ANOVA test showed significant results among the mean values of the Binvestment subgroups while LSD test showed non-significance between the (RA) and both the (RC) and (RLC) subgroups. On the other hand, significance was present between the (RLC) and (RA)of the Winvestment subgroups while non-significance was located between the (RC) and both the (RLC) and (RA) subgroups. Comparing similar subgroups of the two tested investments, the Student's t-test showed non-significance between the (RC) subgroups while high significance was located between the (RLC) and (RA) subgroups respectively.Concerning the vertical marginal discrepancy of the copings, applying the (RC) technique for both investments caused non-statistical significance between the labial, mesial, palatal, and distal aspects.The (RLC) technique caused high significance between the four aspects, while the (RA) technique caused non-significance between the labial aspect only and the others. Conclusion: The Iraqi investment generally produced less vertical marginal discrepancies (using the three different investing and burn-out techniques) than the commercial investment.In order to achieve a better marginal fit, it seems that ceramometalcopings invested with the commercial investment tested are better be cast using the conventional ring investing and burnout technique.
This study aimed to develop a more accurate model for predicting the widths of unerupted canines and premolars in Emirati children, using deep learning and machine learning techniques. Dental models of 380 Emirati individuals aged 15–30 years were collected. The mesiodistal widths of permanent teeth were measured with a standardized orthodontic digital caliper. Regression models were developed using linear regression, Support Vector Regression (SVR; machine learning), and Artificial Neural Networks (ANN; deep learning). The widths of mandibular lateral incisors, central incisors, and the summed width of mandibular incisors were used as predictors. A two-tail
Background: Many types of instruments and techniques are used in the instrumentation of the root canal system. These instruments and techniques may extrude debris beyond the apical foramen and may cause post-instrumentation complications. The aim of this study was to evaluate the amount of apically extruded debris resulted by using 4 types of nickel-titanium instruments (WaveOne, TRUShape 3D conforming files, Hyflex CM, and One Shape files) during endodontic instrumentation. Materials and methods: Forty freshly extracted human mandibular second premolar with straight canals and a single apex were collected for this study. All teeth were cut to similar lengths. Pre-weighted glass vials were used as collecting containers. Samples were randoml
... Show MoreThe research dealt with a topic that has been practiced and transmitted news in satellite channels in recent years a lot. That is to say the role of satellite channels in the culture of a protest. In general, this study aims to reach to know the extent of the impact of television, especially the impact of the programs that bear the contents of protest and remonstration on the public; and what can be resulted out of these programs as cognitive, emotional and behavioral effects as a result of the individual's exposure to these programs and their impact from the culture of pretense. In addition to that, the research was interested in explaining the role of Iraqi satellite channels in developing and cultivating such culture; and following up
... Show MoreIt is found that hypersensitive teeth have a larger number and wider patent tubules than those of non-sensitive teeth. Objective: The aim of this study is to compare between the effects of diode laser at different power densities, with and without sodium fluoride on the sealing of exposed dentinal tubules and dentin permeability. Materials and methods: 118 teeth were used. Samples were divided into three major groups. The first consisted of 100 teeth used for permeability test. The second consisted of 16 teeth for measuring external surface temperature elevation while irradiation. The third, in turn, consisted of one pair of teeth observed under SEM for dentine surface morphology analysis. Results: For dentin permeability measurement, th
... Show MorePoly-ether-ether-ketone (PEEK) was introduced in dentistry as an alternative to metal alloys.
To assess the effectiveness of PEEK-fixed retainers in preserving the stability of mandibular anterior and participant satisfaction as compared to the Dead-soft coaxial fixed retainer (DSC).
A single-centre, two-arm parallel groups
In this paper, the dynamical behavior of a three-dimensional fractional-order prey-predator model is investigated with Holling type III functional response and constant rate harvesting. It is assumed that the middle predator species consumes only the prey species, and the top predator species consumes only the middle predator species. We also prove the boundedness, the non-negativity, the uniqueness, and the existence of the solutions of the proposed model. Then, all possible equilibria are determined, and the dynamical behaviors of the proposed model around the equilibrium points are investigated. Finally, numerical simulations results are presented to confirm the theoretical results and to give a better understanding of the dynami
... Show MoreHTH Ali Tarik Abdulwahid , Ahmed Dheyaa Al-Obaidi , Mustafa Najah Al-Obaidi, eNeurologicalSci, 2023
Recently emerging pandemic SARS CoV-2 conquered our world since December 2019. Continuous efforts have been done to find out effective immunization and precise treatment stetratigies A way from therapeutic options that were tried in SARS CoV-2, an increased attention is directed to predict natural products and mainly phytochemicals as collaborative measures for this crisis. In this review, most of the mentioned compounds specially flavonoids (biacalin, hesperidin, quercetin, luteolin,, and phenolic (resveratrol, curcumin, and theaflavin) exert their effect through interfering with the action of one or more of this proteins (spike protein, papain like protease, 3 chymotrypsin like cysteine protease, and RNA dependent RNA
... Show MoreThe effect of thermal treatment on optical constants of pure PMMA and with addition (15 and 35) ml of coumarin at different temperatures (100, 110 and 120) C0 for 1 hour were investigated. Cast method used to prepares films of pure PMMA and PMMA with (15 and 35) of coumarin. UV/VIS spectrometer technique used to measure the absorption spectra for these films. The optical constant (absorption spectra and absorption coefficient) don’t changes after applied temperatures in pure PMMA film but the optical constant (absorption spectra and absorption coefficient) in PMMA with (15 and 35) ml of coumarin increased with applied temperatures. The optical energy gap of pure PMMA and PMMA with (15 and 35) ml of coumarin sl
... Show More