Background: Dentin removed during root canal system instrumentation for creating adequate geometry for the canal and cleaning the canal. A new instrument had been marketed with the aim of optimum shaping of all parts of the canal system, however, no information present about the amount of dentin removal compared to conventional rotary system. This study investigated the amount of dentin removal when the canal instrumented by SAF compared with ProTaper by using high resolution computed tomography (micro CT). Materials and Methods: Twenty extracted single canalled teeth were utilized for this study; and randomly divided into 2 groups. In the first group, the root canals were prepared by using protaper rotary system till F2 and the root canal irrigated with 1ml of normal saline after each instrument. The root canals in the second group were prepared using SAF for 2min, with continuous irrigation (normal saline). After rescanning, the amount of dentin removal was calculated. Result: It was clear that the use of SAF system had increase the amount of dentin removal and in quantity larger than that did by ProTaper system & the mean of net difference was (0.288mm ± 0.051). By using t-independent test, there was highly significant difference between the two groups at (p=0.001), with in favor of the SAF system over ProTaper system at p< 0.01; in dentin removal quantity Conclusion: Root canal preparation with SAF-system resulted in more and effectively removed dentin when compared with protaper rotary files.
This research aims to choose the appropriate probability distribution to the reliability analysis for an item through collected data for operating and stoppage time of the case study.
Appropriate choice for .probability distribution is when the data look to be on or close the form fitting line for probability plot and test the data for goodness of fit .
Minitab’s 17 software was used for this purpose after arranging collected data and setting it in the the program.
&nb
... Show MoreThe IGRF model is the empirical representation of the Earth magnetic field recommended for scientific use by the International Association of Geomagnetism and Aeronomy(IAGA).
Since the Geomagnetic field has the abi lity to change the orientation of satellite, the strength of Geomagnetic field and its horizontal component have been studied.
This paper discusses the phenomenon of the Geomagnetic field intensity and its horizontal component at diferent altitudes and at certain latitudes, the geomagnetic field data is obtained by using IGRF2000 model at Baghdad (44.7 degree East longitude) .
Sorption is a key factor in removal of organic and inorganic contaminants from their aqueous solutions. In this study, we investigated the removal of Xylenol Orange tetrasodium salt (XOTS) from its aqueous solution by Bauxite (BXT) and cationic surfactant hexadecyltrimethyl ammonium bromide modified Bauxite (BXT-HDTMA) in batch experiments. The BXT and BXT-HDTMA were characterized using FTIR, and SEM techniques. Adsorption studies were performed at various parameters i.e. temperature, contact time, adsorbent weight, and pH. The modified BXT showed better maximum removal efficiency (98.6% at pH = 9.03) compared to natural Bauxite (75% at pH 2.27), suggesting that BXT-HDTMA is an excellent adsorbent for the removal of XOTS from water. The equ
... Show MoreEffect of nano and micro SiO2 particles with different weight percent (2,4,6,8 and 10) %wt on the Interlaminar fracture toughness (GIc) of 16-plies of woven roving glass fiber /epoxy composites prepared by hand lay – up technique were investigated. The specimens were tested using DCB test (mode I).
Area method was used to compute the interlaminar fracture toughness. The results show that, GIc would increase with the increasing in the filler content, the main failure in microcomposites and nanocomposites was delamination in the layers, the delamination reduced with increasing in the filler content.
In this paper, a sufficient condition for stability of a system of nonlinear multi-fractional order differential equations on a finite time interval with an illustrative example, has been presented to demonstrate our result. Also, an idea to extend our result on such system on an infinite time interval is suggested.
The challenge in studying fusion reaction when the projectile is neutron or proton rich halo nuclei is the coupling mechanism between the elastic and the breakup channel, therefore the motivation from the present calculations is to estimate the best coupling parameter to introduce the effect of coupled-channels for the calculations of the total cross section of the fusion , the barrier distribution of the fusion and the average angular momentum 〈L〉 for the systems 6He+206Pb, 8B+28Si, 11Be+209Bi, 17F+208Pb, 6He+238U, 8He+197Au and 15C+232Th using quantum mechanical approach. A quantum Coupled-Channel Calculations are performed using CC code. The predictions of quantum mechanical approach are comparable with the measured data that is
... Show MoreThis study is concerned with the evaluation of the effect of Euphrates River water quality in Al-Samawa region during
the period 1984-2003 on efficiency and reliability of reverse osmosis desalination systems by calculating the calcium
sulfate scaling index depending on the following indicators: - TDS, Ca+2, Mg+2, Na+1, Cl-1, So4-2, HCO3-1. It was
found from data analysis that this index for these units is greater than permissible limit. Also, the fitted relationship
between this index and TDS is logarithmic, i.e. this index varies more rapidly than TDS, and consequently it is more
representative to the water quality than TDS.