Background: The bonded orthodontic retainer constructed from multistrand wire and composite is an efficient esthetic retainer, which can be maintained long-term. Clinical failures of bonded orthodontic retainers, most commonly at the wire/composite interface, have been reported. This in vitro investigation aimed to evaluate the tensile forces of selected multistrand wires and composite materials that are available for use in the construction of bonded fixed retainers. Materials and Methods: The study sample includes 120 wires with three types of retainer wires (3 braided strands\ Orthotechnology, 8 braided strands\ G&H Orthodontics, 6 coaxial strands\ Orthoclassic wires), two types of adhesive (flowable\ Orthotechnology, non flowable\ G&H Orthodontics composites) and two thickness of the adhesive (1mm, 2mm). The samples were prepared for each composite in which a wire was embedded; then the composite was light cured for 40 seconds and the specimens were stored in artificial saliva at 37°C in the incubator for 24 hours. The ends of the wire were drawn up and tensile force was applied through Tinius-Olsen universal testing machine until the resin failed and the results were recorded in Newton (N). Results: Statistical analysis showed that there was a highly significant difference (P ≤ 0.01) among the mean values of tensile forces of the three types of retainer wires in each thickness of composite with exception of a non significant difference (P > 0.05) between (3 braided) and (8 braided) and a non significant difference (P > 0.05) between (3 braided) and (6 coaxial) in both thickness of composite, a highly significant difference (P ≤ 0.01) between the two thickness of both composite types in each wire type and a highly significant difference (P ≤ 0.01) between the two types of composite in each wire type of both thickness of composite. Conclusion: The result of this study revealed that the 8 braided strands retainer wire shows the highest values of tensile force among the tested retainer wires, the non flowable composite demonstrates a higher tensile force than the flowable composite and increasing the thickness of composite overlying the wire increased the force required to detach the wire from the composite.
KE Sharquie, JR Al-Rawi, AA Noaimi, HM Al-Hassany, Journal of drugs in dermatology: JDD, 2012 - Cited by 47
The principal forms of radiation dosage for humans from spontaneous radiation material are being recognized as radon and its progenitors in the interior environment. Radiation-related health risks are caused by radon in water supply, which can be inhaled or ingested. Materials and Methods: The solid-state CR-39 nuclear trace detectors method was using in this research for measuring accumulation of radioactivity in water supply in different locations of Iraq's southwest corner of Baghdad. In Baghdad district, 42 samples were selected from 14 regions (3 samples out of each region) and put in dosimeters for 50 days. Results: The mean radon concentration was 49.75 Bq/m3, that is lower than the internationally recognized limit of 1100 Bq /m3. Th
... Show More
At the last two decades , The environment has witnessed tremendous changes in many fields with the huge competition , various technological development and customer satisfaction , that are reflected in economic units a doption for lean production system.
Lean accounting that has appeared as a response for change occurred of economic units adoption for changes occurred of economic units adoption for lean production instead of wide production system , has devised new performance measures suitable for economic units adoption for lean ideas: and helping in providing suitable information about evaluating economic unit performance , these measures are divided into three levels , cell level,value flow level , a
... Show MoreThe experiment was conducted in field of the University of Baghdad, Jadryia region, Baghdad to measure vibration and performance efficiency of grass mower (machine cutting grass). Vibration in three axes are longitudinal X , lateral Y and vertical Z in four places of mower machine during cutting grass and Practical Productivity, Efficiency and Fuel Consumption measured in this experiment . Factorial design (3 x 2) used, mower speeds included 1.9 3.6 and 6.4 km/hr and engine load included idling and full load according to randomized complete design were used in this experiment. Least Significant Design (LSD) 0.05 was used to compare the mean of treatment. Result were showed that the mower speed 6.4 km/hr recorded high productivity (0.6557 ha
... Show MoreThe characters of facades' form of the Iraqi building after 2003 have been changed, it has been described by many names. The problem of the research is that what are the features of the characters of the form in the façades of the buildings in Baghdad city after 2003? Are the façade of the individual houses or the commercial buildings is the heaviest in the visual weight? The research aims to answer those questions by choosing the vernacular architecture as a measurement tool. It is the informal image of the architecture, which is built by people informally and spontaneously, without official control and legislation to be organized. This is smellier to what has happened in Baghdad, after 2003 according to previous stud
... Show MoreThe general trend in Iraqi banks is focused towards the application of international financial reporting standards, especially the international financial reporting standard IFRS 9 “Financial Instruments”, in addition to the directives issued on the Central Bank of Iraq’s instructions for the year 2018 regarding the development of expected credit losses models, and not to adhere to a specific method for calculating these losses and authorizing the banks’ departments to adopt the method of calculating losses that suits the nature of the bank’s activity and to be consistent in its use from time to time. The research problem revolves around the different methodologies for calculatin
... Show More