Preferred Language
Articles
/
jbcd-470
Tensile force measurement by using different lingual retainer wires, bonding materials types and thickness (A comparative in vitro study)
...Show More Authors

Background: The bonded orthodontic retainer constructed from multistrand wire and composite is an efficient esthetic retainer, which can be maintained long-term. Clinical failures of bonded orthodontic retainers, most commonly at the wire/composite interface, have been reported. This in vitro investigation aimed to evaluate the tensile forces of selected multistrand wires and composite materials that are available for use in the construction of bonded fixed retainers. Materials and Methods: The study sample includes 120 wires with three types of retainer wires (3 braided strands\ Orthotechnology, 8 braided strands\ G&H Orthodontics, 6 coaxial strands\ Orthoclassic wires), two types of adhesive (flowable\ Orthotechnology, non flowable\ G&H Orthodontics composites) and two thickness of the adhesive (1mm, 2mm). The samples were prepared for each composite in which a wire was embedded; then the composite was light cured for 40 seconds and the specimens were stored in artificial saliva at 37°C in the incubator for 24 hours. The ends of the wire were drawn up and tensile force was applied through Tinius-Olsen universal testing machine until the resin failed and the results were recorded in Newton (N). Results: Statistical analysis showed that there was a highly significant difference (P ≤ 0.01) among the mean values of tensile forces of the three types of retainer wires in each thickness of composite with exception of a non significant difference (P > 0.05) between (3 braided) and (8 braided) and a non significant difference (P > 0.05) between (3 braided) and (6 coaxial) in both thickness of composite, a highly significant difference (P ≤ 0.01) between the two thickness of both composite types in each wire type and a highly significant difference (P ≤ 0.01) between the two types of composite in each wire type of both thickness of composite. Conclusion: The result of this study revealed that the 8 braided strands retainer wire shows the highest values of tensile force among the tested retainer wires, the non flowable composite demonstrates a higher tensile force than the flowable composite and increasing the thickness of composite overlying the wire increased the force required to detach the wire from the composite.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 07 2014
Journal Name
Baghdad Science Journal
A Study Of Corrosion Behavior Of Low Carbon Steel In Acidic And Basic Washing Water Of Crude Oil Solution At Different Temperatures
...Show More Authors

The corrosion behavior of low carbon steel in washing water of crude oil solution has been studied potentiostatically at five temperatures in the range ( 303 –343 )K, at pH ( 4 ) and at pH (4,6,7,9,11 ) at (343K)..The corrosion potential shifted to more negative values with increasing temperature and the corrosion current density increased with increasing temperature, the corrosion current density (icorr) decreased with increasing pH in the rang ( 4 – 7 ) and it increased with increasing pH in the rang ( 9 – 11 ) at ( 343 K ), while the corrosion potential generally variation with increasing pH in the rang (4-11)at(343K. From the general results for this study can be seen that thermodynamic and kinetic function were

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Sep 17 2021
Journal Name
Al-kindy College Medical Journal
Single Layer Extra-Mucosal Versus Double Layer Intestinal Anastomosis for Colostomy Closure: A Prospective Comparative Study
...Show More Authors

Background: The main objective was to compare the outcome of single layer interrupted extra-mucosal sutures with that of double layer suturing in the closure of colostomies.

Subjects and Methods: Sixty-seven patients with closure colostomy were assigned in a prospective randomized fashion into either single layer extra-mucosal anastomosis (Group A) or double layer anastomosis (Group B). Primary outcome measures included mean time taken for anastomosis, immediate postoperative complications, and mean duration of hospital stay. Secondary outcome measures assessed the postoperative return of bowel function, and the overall mean cost. Chi-square test and student t-test did the statistical analysis..

Resu

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Dec 21 2020
Journal Name
International Journal Of Environmental Analytical Chemistry
Comparative study of embedded functionalised MWCNTs and GO in Ultrafiltration (UF) PVC membrane: interaction mechanisms and performance
...Show More Authors

View Publication
Scopus (42)
Crossref (40)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Ieee Access
IFFT-Based Microwave Non-Destructive Testing for Delamination Detection and Thickness Estimation
...Show More Authors

View Publication
Scopus (14)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
A Study on the Stability of Different Frusemide Liquid Dosage Formulas: Oral Solution, Syrup, Elixir, Suspension and Emulsion
...Show More Authors

The present study aim at preparing frusemide in liquid form suitable for oral use. This is achieved through preparing different liquid forms of frusemide. The frusemide liquid is prepared in the following forms: oral solution, syrup and elixir with intensity of 1, 0.4 and 0.8% weight /volume respectively and in combination with potassium carbonate, polysorbate 80, alcohol and phosphate buffer solution of pH8 to dissolve the frusemide in the above mentioned forms. The different forms of the prepared medicine have been stored in glass bottles that can provide protection against light and at 40, 50, 600C for four months. Besides the pH has been checked to decide the period of validity. The results show that the expiration date of

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jun 01 2022
Journal Name
Journal Of The College Of Languages
Free will between Slavery and Freedom: A Study of Linda Brent in Incidents in the Life of a Slave Girl by Harriet Jacobs
...Show More Authors

Harriet Jacobs was a writer and a reformer. As a female writer in the nineteenth century, Jacobs wrote her narrative as a means of resisting the system of slavery. She wrote her book Incidents in the Life of a Slave Girl: Written by Herself, (1842) to reflect upon the exploitation of the black people and the need to change the hierarchal attitude that governs white/black relations. She was engaged in many abolitionist events and her anti-slavery approach appeared clearly in her writings. She shares Du Bios ideas about freedom and emancipation and the need for a political and cultural change. Thus, Du Bois’s theory provides a framework for her autobiographical novel where she portrays Linda Brent, the main character, a strong wille

... Show More
View Publication
Crossref
Publication Date
Wed Jun 01 2022
Journal Name
Journal Of The College Of Languages (jcl)
Free will between Slavery and Freedom: A Study of Linda Brent in Incidents in the Life of a Slave Girl by Harriet Jacobs
...Show More Authors

Harriet Jacobs was a writer and a reformer. As a female writer in the nineteenth century, Jacobs wrote her narrative as a means of resisting the system of slavery. She wrote her book Incidents in the Life of a Slave Girl: Written by Herself, (1842) to reflect upon the exploitation of the black people and the need to change the hierarchal attitude that governs white/black relations. She was engaged in many abolitionist events and her anti-slavery approach appeared clearly in her writings. She shares Du Bios ideas about freedom and emancipation and the need for a political and cultural change. Thus, Du Bois’s theory provides a framework for her autobiographical novel where she portrays Linda Brent, the main character, a strong w

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Sep 15 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Retentive forces, tensile strength and deflection fatigue of Acetal thermoplastic clasp material in comparison with cobalt-chromium alloy
...Show More Authors

Background: Nowadays there is an increasing of the emphasis on aesthetic, dentist have been concerned about providing aesthetics and functional removable partial dentures to their patients and this was make the mission more difficult because of the goal now is achieving optimal aesthetic of the denture - while maintaining retentive, stable, and conservative to the health of supporting tooth and supporting tissue. The traditional use of metal clasp like cobalt-chromium, gold, stainless-steel and titanium hampers esthetics because of its obvious display conflicts with patient’s prosthetic confidentiality. Acetal resin (poly oxy methylene) may be used as alternative denture clasp material. This material was promoted primarily on the basis of

... Show More
View Publication Preview PDF
Publication Date
Mon Aug 01 2016
Journal Name
2016 3rd International Conference On Computer And Information Sciences (iccoins)
Measurement model of e-SQ dimensions and users' satisfaction in Malaysia IHL
...Show More Authors

View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Tue Dec 15 2020
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees20
A comparative study of Williamson-Hall method and size-strain method through X-ray diffraction pattern of cadmium oxide nanoparticle
...Show More Authors

In this research, the Williamson-Hall method and of size-strain plot method was employed to analyze X- ray lines for evaluating the crystallite size and lattice strain and of cadmium oxide nanoparticles. the crystallite size value is (15.2 nm) and (93.1 nm) and lattice strain (4.2 x10−4 ) and (21x10−4) respectively. Also, other methods have been employed to evaluate the crystallite size. The current methods are (Sherrer and modified Sherrer methods ) and their results are (14.8 nm) and (13.9nm) respectively. Each method of analysis has a different result because the alteration in the crystallite size and lattice strain calculated according to the Williamson-Hall and size-strain plot methods shows that the non-uniform strain in nan

... Show More
View Publication
Scopus (31)
Crossref (22)
Scopus Clarivate Crossref