Preferred Language
Articles
/
jbcd-470
Tensile force measurement by using different lingual retainer wires, bonding materials types and thickness (A comparative in vitro study)
...Show More Authors

Background: The bonded orthodontic retainer constructed from multistrand wire and composite is an efficient esthetic retainer, which can be maintained long-term. Clinical failures of bonded orthodontic retainers, most commonly at the wire/composite interface, have been reported. This in vitro investigation aimed to evaluate the tensile forces of selected multistrand wires and composite materials that are available for use in the construction of bonded fixed retainers. Materials and Methods: The study sample includes 120 wires with three types of retainer wires (3 braided strands\ Orthotechnology, 8 braided strands\ G&H Orthodontics, 6 coaxial strands\ Orthoclassic wires), two types of adhesive (flowable\ Orthotechnology, non flowable\ G&H Orthodontics composites) and two thickness of the adhesive (1mm, 2mm). The samples were prepared for each composite in which a wire was embedded; then the composite was light cured for 40 seconds and the specimens were stored in artificial saliva at 37°C in the incubator for 24 hours. The ends of the wire were drawn up and tensile force was applied through Tinius-Olsen universal testing machine until the resin failed and the results were recorded in Newton (N). Results: Statistical analysis showed that there was a highly significant difference (P ≤ 0.01) among the mean values of tensile forces of the three types of retainer wires in each thickness of composite with exception of a non significant difference (P > 0.05) between (3 braided) and (8 braided) and a non significant difference (P > 0.05) between (3 braided) and (6 coaxial) in both thickness of composite, a highly significant difference (P ≤ 0.01) between the two thickness of both composite types in each wire type and a highly significant difference (P ≤ 0.01) between the two types of composite in each wire type of both thickness of composite. Conclusion: The result of this study revealed that the 8 braided strands retainer wire shows the highest values of tensile force among the tested retainer wires, the non flowable composite demonstrates a higher tensile force than the flowable composite and increasing the thickness of composite overlying the wire increased the force required to detach the wire from the composite.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Mar 11 2020
Journal Name
Journal Of Cardiovascular Disease Research
Resistive Index is an Early Indicator for Flow Deterioration in Comparison with Intima Media Thickness for Patients with Hypertension and Diabetes in Relation to Age
...Show More Authors

Background: Atherosclerosis is well known related to age and certain cardiovascular diseases. Aging is one reason of arteries function deterioration which can cause loss of compliance and plaque accumulation, this effect increases by the presence of certain diseases such as hypertension and diabetes disease. Aim: To investigate the reduction of blood supply to the brain in patients with diabetes and hypertension with age and the role of resistive index in the diagnosis of reduced blood flow. Method: Patients with both diseases diabetic and hypertension were classified according to their age to identify the progression of the disease and factors influencing the carotid artery blood flow. By using ultrasound and standard Doppler techniq

... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Research In Pharmacy
Preparation and in-vitro evaluation of Carbopol hydrogel of clobetasol-loaded ethylcellulose microsponges
...Show More Authors

: Clobetasol propionate (CP) is a potent corticosteroid used for skin conditions but often causes side effects due its systemic absorption. To improve its solubility and reduce it side effects (like skin irritation, skin atrophy, hypopigmentation and steroidal acne), Microsponge (Msg) has been employed as a unique three-dimensional particle that can encapsulate hydrophilic and lipophilic drugs. This study aims to develop and evaluate CP Msg-loaded hydrogels. Two Clobetasol-loaded ethylcellulose-based Msg formulas were prepared using the quasi-emulsion solvent diffusion method, then they were incorporated into Carbopol hydrogel. Two ratios of Carbopol 940 (1% and 1.5% w/w) were used. The prepared hydrogel were assessed for appearance, pH, dr

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Dec 01 2012
Journal Name
Al Mustansiriyah Journal Of Pharmaceutical Sciences
Formulation and In Vitro Evaluation of Mucoadhesive Antimicrobial Vaginal Tablets of Ciprofloxacin Hydrochloride
...Show More Authors

Ciprofloxacin is a broad spectrum fluoroquinolone, effective in the treatment of a wide range of infections, including genitourinary tract infections.In this study, bioadhesive vaginal tablets of ciprofloxacin hydrochloride were prepared by direct compression method using a combination of bioadhesivepolymers carbopol 934P(Cp), carboxymethylcellulose (CMC) and sodium alginate (SA) in different ratios.The prepared tablet formulations were characterized by measuring their swelling capacity, surface pH, bioadhesive properties, and in-vitro drug dissolution. It was found that the bioadhesive force was directly proportional to carbopol 934P content in different formulae and was further enhanced by the inclusion of carboxymethylcellulose.

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Feb 02 2022
Journal Name
Journal Of University Of Shanghai For Science And Technology
Antiparasitic activity of Artemether and combination Artemether with Artemisinin against Leishmaniasis, in vitro.
...Show More Authors

The Leishmania donovani parasite causes visceral leishmaniasis (VL), an acute and fatal form of leishmaniasis. Because traditional therapy alternatives, such as glucantime and other pentavalent medicines, are toxic and have side effects, new treatments with fewer negative effects are needed. Only a handful of drugs are clinically beneficial to treatments of the disease, but considerable limitations threaten their very usage. Novel, safe, and efficient drugs, including those against antimalaria and leishmaniasis co-infections, are so essential. Artemether (ATM) is an Artemisinin derivative that has been demonstrated to be useful in the treatment of malaria and, more recently, leishmaniasis. The current research was carried out to evaluate th

... Show More
Publication Date
Thu Jan 04 2018
Journal Name
International Journal Of Applied Pharmaceutics
FORMULATION AND IN VITRO EVALUATION OF BROMOCRIPTINE MESYLATE AS FAST DISSOLVING ORAL FILM
...Show More Authors

Objective: The aim of this study was to formulate and in vitro evaluate fast dissolving oral film of practically insoluble bromocriptine mesylate to enhance its solubility and to improve its oral bioavailability by avoiding first pass effect as well as to produce an immediate release action of the drug from the film for an efficient management of diabetes mellitus type II in addition to an improvement of the patient compliance to this patient- friendly dosage form. Methods: The films were prepared by the solvent casting method using hydroxypropyl methylcellulose of grades (E3, E5, E15), polyvinyl alcohol (PVA), pectin and gelatin as film-forming polymers in addition to polyethene glycol 400 (PEG400), propylene glycol (PG) and glycerin were

... Show More
Scopus (28)
Scopus
Publication Date
Sun Feb 28 2021
Journal Name
Journal Of Electrochemical Science And Technology
Simultaneous Removal of Cadmium and Copper from a Binary Solution by Cathodic Deposition Using a Spiral-Wound Woven Wire Meshes Packed Bed Rotating Cylinder Electrode
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Vibration Measurement and Analysis of knee-Ankle-Foot Orthosis (KAFO) Metal-Metal type
...Show More Authors

This paper deals with calculate stresses in Knee-Ankle-Foot-Orthosis as a result of the effect vibration during gait cycle for patient wearing KAFO .Experimental part included measurement interface pressure between KAFO and leg due to action muscles and body weigh on Orthosis. also measurement acceleration result from motion of defected leg by accelerometer .Results of Experimental part used input in theoretical part so as to calculate stresses result from applying pressure and acceleration on KAFO by engineering analysis program ANSYS 14.Resultes show stresses values in upper KAFO greater than lower KAFO that is back to muscles more effective in thigh part lead to recoding pressure higher than pressure in shank part.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Mar 30 2021
Journal Name
Baghdad Science Journal
Measurement of some Air Pollutantsin Printing Units and Copy Centers Within Baghdad City
...Show More Authors

Emissions of particulate matter from nanopapers as well as inks and organic solvents during the printing operationand copying machines constitute a threat to human health, especially with long time exposure in closed working environments. The present study was conducted in some printing houses and copying centers of Baghdad city during February and April  .The studyproved the occurrence of an air pollution problem concerning lead and zinc contents in all the study sites. The levels of Pb, Zn and Cu were collected by low volume sampler from the air of the study sites then filter papers digested and determined the heavy metals by flame atomic spectrophotometer. Particulate matter was measured by Aerocet, Microtector  meter device was use

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Fri Dec 25 2009
Journal Name
Wireless Personal Communications
A N-Radon Based OFDM Trasceivers Design and Performance Simulation Over Different Channel Models
...Show More Authors

In this paper a new method is proposed to perform the N-Radon orthogonal frequency division multiplexing (OFDM), which are equivalent to 4-quadrature amplitude modulation (QAM), 16-QAM, 64-QAM, 256-QAM, ... etc. in spectral efficiency. This non conventional method is proposed in order to reduce the constellation energy and increase spectral efficiency. The proposed method gives a significant improvement in Bit Error Rate performance, and keeps bandwidth efficiency and spectrum shape as good as conventional Fast Fourier Transform based OFDM. The new structure was tested and compared with conventional OFDM for Additive White Gaussian Noise, flat, and multi-path selective fading channels. Simulation tests were generated for different channels

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Tue Oct 01 2024
Journal Name
The Saudi Dental Journal
Different pulp capping agents and their effect on pulp inflammatory response: A narrative review
...Show More Authors

View Publication
Scopus (5)
Crossref (5)
Scopus Clarivate Crossref