Background: The bonded orthodontic retainer constructed from multistrand wire and composite is an efficient esthetic retainer, which can be maintained long-term. Clinical failures of bonded orthodontic retainers, most commonly at the wire/composite interface, have been reported. This in vitro investigation aimed to evaluate the tensile forces of selected multistrand wires and composite materials that are available for use in the construction of bonded fixed retainers. Materials and Methods: The study sample includes 120 wires with three types of retainer wires (3 braided strands\ Orthotechnology, 8 braided strands\ G&H Orthodontics, 6 coaxial strands\ Orthoclassic wires), two types of adhesive (flowable\ Orthotechnology, non flowable\ G&H Orthodontics composites) and two thickness of the adhesive (1mm, 2mm). The samples were prepared for each composite in which a wire was embedded; then the composite was light cured for 40 seconds and the specimens were stored in artificial saliva at 37°C in the incubator for 24 hours. The ends of the wire were drawn up and tensile force was applied through Tinius-Olsen universal testing machine until the resin failed and the results were recorded in Newton (N). Results: Statistical analysis showed that there was a highly significant difference (P ≤ 0.01) among the mean values of tensile forces of the three types of retainer wires in each thickness of composite with exception of a non significant difference (P > 0.05) between (3 braided) and (8 braided) and a non significant difference (P > 0.05) between (3 braided) and (6 coaxial) in both thickness of composite, a highly significant difference (P ≤ 0.01) between the two thickness of both composite types in each wire type and a highly significant difference (P ≤ 0.01) between the two types of composite in each wire type of both thickness of composite. Conclusion: The result of this study revealed that the 8 braided strands retainer wire shows the highest values of tensile force among the tested retainer wires, the non flowable composite demonstrates a higher tensile force than the flowable composite and increasing the thickness of composite overlying the wire increased the force required to detach the wire from the composite.
Background: The combination of thermoplastic nylon resin materials and auto polymerizing resin is necessary in some situation for repair and adjustment. This study evaluated shear bond strength between thermoplastic nylon material (flexible) and auto polymerizing acrylic resin subjected to holes and silica coated layer. Materials and Method: Forty five (45) specimens were prepared from flexible acrylic bonded to auto-polymerizing acrylic resin and divided into three groups according to the surface treatments as follows: Group A: 15 specimens of flexible acrylic bonded with cold-cure acrylic by holes. Group B: 15 specimens of flexible acrylic bonded with cold-cure acrylic by silica coated layer. Group C: 15 specimens of flexible acrylic bon
... Show MoreThe present study aimed to investigate the anatomy, histology, and immunohistochemistry of parathyroid gland in two Iraqi mammals (Weasel, Herpestes javanicus and Long-ear hedgehog, Hemiechinus auritus) as a comparative study. A total of (20) animal for each species were used in the present study. Animals collected were immediately anesthesia and dissected to get the parathyroid gland. Methods of Humason and Bancroft and Stevens were employed for histological techniques. Different stains were used (Hematoxylin- Eosin stain-(H & E), Periodic Acid Schiff stain-(PAS), Azan stain, and Methyl Blue stain-(MB)) for staining the histological sections. Anti-calcitonin, code140778 marker used for immune-histochemical study. Results of the present stu
... Show MoreBackground: The ideal maxillofacial prosthesis should have fine and thin boundaries that bindwith the surrounding facial structures and possess high tear strength.This study aims to determinethe best percentages of nanofiller (TiO2) and intrinsic pigment (silicone functional intrinsic) thatcould be mixed in as additives to improve the tear strength of Cosmesil M511 andVST50F siliconeelastomers with the least effect on their hardness.Materials and Methods: In this in vitro experimental study, a total of 80 samples, 40 for eachelastomer, were fabricated. Each elastomer sample was split into two equal groups to test for tearstrength and Shore A hardness. Each group consisted of 20 samples, including 10 control sampleswithout additives and 10 e
... Show MoreObjectives To tailor composites of polyethylene–hydroxyapatite to function as a new intracanal post for the restoration of endodontically treated teeth (ETT). Methods Silanated hydroxyapatite (HA) and zirconium dioxide (ZrO2) filled low-density polyethylene (LDPE) composites were fabricated by a melt extrusion process and characterised using infrared spectroscopy (FTIR), differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA). The flexural strength and modulus were determined in dry state and post ageing in simulated body fluid and fractured surfaces analysed by SEM. The water uptake and radiographic appearance of the experimental composites were also measured and compared with a commercially known endodontic fibre
... Show MoreThis work presents the modeling of the electrical response of monocrystalline photovoltaic module by using five parameters model based on manufacture data-sheet of a solar module that measured in stander test conditions (STC) at radiation 1000W/m² and cell temperature 25 . The model takes into account the series and parallel (shunt) resistance of the module. This paper considers the details of Matlab modeling of the solar module by a developed Simulink model using the basic equations, the first approach was to estimate the parameters: photocurrent Iph, saturation current Is, shunt resistance Rsh, series resistance Rs, ideality factor A at stander test condition (STC) by an ite
... Show MoreIn this paper, a random transistor-transistor logic signal generator and a synchronization circuit are designed and implemented in lab-scale measurement device independent–quantum key distribution systems. The random operation of the weak coherent sources and the system’s synchronization signals were tested by a time to digital convertor.
BACKGROUND: Preterm labour is a major cause of perinatal morbidity and mortality, so it is important to predict preterm delivery using the clinical examination of the cervix and uterine contraction frequency. New markers for the prediction of preterm birth have been developed such as transvaginal ultrasound measurement of cervical length as this method is widely available. OBJECTIVE: To determine, whether transvaginal cervical length measurement predicts imminent preterm delivery better than digital cervical length measurement in women presented with preterm labour and intact membranes. PATIENTS AND METHODS: Two hundred women presented with preterm labour between 24 and 36+6 weeks of gestation were included in this study. All women subjecte
... Show MoreTransportation Sector classified as one of the services sectors which is without the production activities cannot be complete its rule. Is act asmoving actions which operate at production and non production goals for the organization and individuals insides the country and with others, that is why this sector act as one of the main which is occupied an important status on the way the economic activities and on the level of the economic institutions the transportation work on transforming all the commodities and products from productions locations to consumption location then its effect the productivity process and create the location utility and on the level of economic it considered as one of the economic supportive structure an
... Show MoreABSTRACT Background: Polycystic ovarian syndrome (PCOS) is one of the most important reproductive and endocrine disorders in women at reproductive age. It's associated with metabolic disorder, obesity, insulin resistance and oxidative stress chronic periodontitis and PCOS both of them associated with low chronic grade of inflammation. The prevalence of periodontal disease seems to be higher in women with PCOS. Superoxide dismutase enzyme (SOD) is an important circulating marker and protecting enzyme helping the body tissues to get rid of reactive oxygen species (ROS) that damage the tissue. Aim of the study: The aim of this study was to measure and compare the levels of (SOD) among group of chronic periodontitis patients with PCOS, group
... Show MoreA ventricular septal defect (VSD) is defined as a communication between the left and right ventricles or between the left ventricle and the right atrium. VSDs are amongst the most common abnormalities of the heart. They can be present in isolation or in association with other congenital cardiac abnormalities. This is study done with the aim to evaluate the types, size, associated CHD with ventricular septal defect in children and adolescent in two cardiac centers (Medical City Complex cardiac clinics, Ibn Al Nafaes teaching hospital) in Baghdad - Iraq