Preferred Language
Articles
/
jbcd-470
Tensile force measurement by using different lingual retainer wires, bonding materials types and thickness (A comparative in vitro study)
...Show More Authors

Background: The bonded orthodontic retainer constructed from multistrand wire and composite is an efficient esthetic retainer, which can be maintained long-term. Clinical failures of bonded orthodontic retainers, most commonly at the wire/composite interface, have been reported. This in vitro investigation aimed to evaluate the tensile forces of selected multistrand wires and composite materials that are available for use in the construction of bonded fixed retainers. Materials and Methods: The study sample includes 120 wires with three types of retainer wires (3 braided strands\ Orthotechnology, 8 braided strands\ G&H Orthodontics, 6 coaxial strands\ Orthoclassic wires), two types of adhesive (flowable\ Orthotechnology, non flowable\ G&H Orthodontics composites) and two thickness of the adhesive (1mm, 2mm). The samples were prepared for each composite in which a wire was embedded; then the composite was light cured for 40 seconds and the specimens were stored in artificial saliva at 37°C in the incubator for 24 hours. The ends of the wire were drawn up and tensile force was applied through Tinius-Olsen universal testing machine until the resin failed and the results were recorded in Newton (N). Results: Statistical analysis showed that there was a highly significant difference (P ≤ 0.01) among the mean values of tensile forces of the three types of retainer wires in each thickness of composite with exception of a non significant difference (P > 0.05) between (3 braided) and (8 braided) and a non significant difference (P > 0.05) between (3 braided) and (6 coaxial) in both thickness of composite, a highly significant difference (P ≤ 0.01) between the two thickness of both composite types in each wire type and a highly significant difference (P ≤ 0.01) between the two types of composite in each wire type of both thickness of composite. Conclusion: The result of this study revealed that the 8 braided strands retainer wire shows the highest values of tensile force among the tested retainer wires, the non flowable composite demonstrates a higher tensile force than the flowable composite and increasing the thickness of composite overlying the wire increased the force required to detach the wire from the composite.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Feb 24 2022
Journal Name
Journal Of Educational And Psychological Researches
Question Asking Skills: Levels, Conditions, Classification, and Types
...Show More Authors

The research aims to know the question asking skills in terms of levels, conditions, classification, and types. The research limited to the literature that dealt with the importance of questioning for students and teachers. The most important term used in the research is the skill (Ryan defined it as "the ability to perform with great efficiency, accuracy, and ease). The results of the research are as follows: 1. the questions asked by the schoolteacher within the assessment of students' learning. 2. Teachers should focus on the lower levels of learning (remembering, understanding and comprehension) and then evaluating students at the higher levels (synthesis and evaluation). 3. Teacher with good knowledge can skillfully use the question

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 11 2025
Journal Name
Academic Science Journal
Review Article: Tumor Markers, Types and Clinical Applications
...Show More Authors

Over the past ten years, tumor markers have played an increasingly important role in clinicaloncology. This trend is expected to continue as technology advances and our knowledge of thehuman body and disease processes grows. In the treatment of cancer, tumor markers are widelyused for a variety of purposes, including screening, selecting a management strategy,determining the prognosis, and post-therapy follow-up. A comprehensive of the fundamentalsof pathophysiology and identification strategies for each specific malignancy is necessary fortheir prudent application in clinical practice. Oncology's use of cancer biomarkers hastransformed the way that cancer is treated, and led to notable improvements in patient outcomesand cancer tre

... Show More
View Publication
Crossref
Publication Date
Fri Oct 30 2020
Journal Name
Journal Of Economics And Administrative Sciences
Accounting measurement of intangible assets (websites) within the framework of international financial reporting standards An applied study between a sample of Iraqi commercial banks)
...Show More Authors

The websites over time have become one of the important tools for communication between individuals among themselves and between individuals and economic units, and they have emerged as one of the important intangible assets to achieve income, as they have become a competitive tool and a marketing outlet for these units and a main means of communication that it uses to exercise its various major activities and achieve potential economic benefits. Therefore, there was a need to measure and display the value of these sites in the financial statements as intangible assets.  Accordingly, the purpose of the research was to determine the costs of the websites owned by the economic unit by way purchase and sites that were created i

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Dec 31 2018
Journal Name
Ibn Al-haitham Jour. For Pure & Appl. Sci
Comparative Study of Thymidine Kinase -1 and Total Antioxidant Capacity in Iraqi Children with Platelet Count Disorder
...Show More Authors

This study aimed to find relationship between thymidine kinase-1 (TK-1) as tumor marker and total antioxidant capacity (TAC) in Iraqi children patients with thrombocytopenia and with thrombocytosis. The present study conducted 60 children patients (30 patients with idiopathic thrombocytopenia purpura (ITP) and 30 patients with thrombocytosis caused by leukemia) attending the Children Fever Hospital in the Medical City / Baghdad, and 30 healthy children as a control group. All study groups were with range ages (1-15) years, and they were diagnosed by assay of platelet count, Prothrombin Time (PT), and partial Thromboplastin Time (PTT). The results shown elevation in plasma TK-1 and TAC values in children patients with thrombocytopenia and w

... Show More
Publication Date
Wed Jun 30 2010
Journal Name
Al-kindy College Medical Journal
Comparative study of the renoprotective effects of captopril and aminophylline against cainst cisplatin – induced nephrotoxicty in rats
...Show More Authors

Background: Cisplatin is one of the most
commonly used anti-cancer drugs , but its
clinical use was limited by its nephrotoxicity .
Methods: In this study we try to investigate the
renoprotective effect of captopril and
aminophylline against cisplatin induced
nephrotoxicity .For this purpose a 36 Sprague
Dawley rats was divided randomly to 6 groups ,
each group consist of 6 rats. The first group
given normal saline and act as control group,
while the other 5 groups given cisplatin ( 7.5
mg/kg ) , captopril ( 60 mg/kg ) , aminophylline
( 24 mg/kg ) , captopril with cisplatin and
aminophylline with cisplatin respectively. All
drugs are given as single dose through
intraperitonial route. After 6

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 30 2011
Journal Name
Al-khwarizmi Engineering Journal
Comparative Study of the Mechanical Properties of (FS) and MIG Welded Joint in (AA7020-T6) Aluminum Alloy
...Show More Authors

A comprehensive practical study of typical mechanical properties of welded Aluminum alloy AA7020-T6 (Al-Mg-Zn), adopting friction stir welding (FSW) technique and conventional metal inert gas (MIG) technique, is well achieved in this work for real comparison purposes. The essences of present output findings were concentrated upon the FSW samples in respect to that MIG ones which can be summarized in the increase of the ultimate tensile strength for FSW was 340 MPa while it was 232 MPa for MIG welding, where it was for base metal 400 MPa. The minimum microhardness value for FSW was recorded at HAZ and it was 133 HV0.05 while it was 70 HV0.05 for MIG weld at the welding metal. The FSW produce 2470 N higher than MIG welding in the bending t

... Show More
View Publication Preview PDF
Publication Date
Fri Oct 30 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of plasma treatment on shear bond strength of soft denture liner with two different types of denture base material (heat cure and light cure)
...Show More Authors

Background: In this study we evaluate the effect of plasma treatment (oxygen and argon) gas in two different exposure times on the surface of heat cure and light cure acrylic resin. Materials and method: 100 specimens of heat cure and light cure acrylic resin were fabricated. The measurements of the samples were (75mm, 25mm and 4.5mm) length, width and depth respectively with stopper of 3mm depth. Two types of gas used oxygen and argon in (5,10) min by using (DC-glow discharge plasma device) then we apply cold cure soft lining material, with the help of Instron machine we test the shear stress value. Results: A highly significant effect after argon and oxygen gases treatment in both 5 and 10 min exposure times on shear bond strength to soft

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Naturally occurring radioactive materials and related hazard indices in Ahdeb oil field
...Show More Authors

In this work, measurements of activity concentration of naturally occurring radioactive materials (NORM) isotopes and their related hazard indices for several materials such as crude oil, sludge and water in Ahdeb oil fields in Waste governorate using high pure germanium coaxial detection technique. The average values for crude oil samples were174.72Bq/l, 43.46Bq/l, 355.07Bq/l, 264.21Bq/l, 122.52nGy/h, 0.7138, 1.1861, 0.601 mSv/y, 0.1503mSv/y and 1.8361 for Ra-226, Ac-228, K-40, Ra eq, D, H-external and H-internal respectively. According to the results; the ratio between 238U to 232Th was 4, which represents the natural ratio in the crust earth; therefore, one can be strongly suggested that the geo-stricture of the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Oct 30 2020
Journal Name
Journal Of Economics And Administrative Sciences
Evaluating the reality of applying the curriculum axis according to the Iraqi academic accreditation standards / a comparative study of a sample of governmental and private universities and colleges
...Show More Authors

The research aims to get acquainted with the evaluation of the reality of the application of the curriculum axis from among the eight Iraqi academic accreditation standards in a sample of governmental and private universities and colleges in Iraq and to identify the main and secondary reasons for it as well as to provide proposed mechanisms and procedures to help reduce gaps, If the research problem is represented in the weak availability of the requirements of the curriculum axis in universities and colleges (the study sample) due to the weak documentation and successful implementation of them and interest in them is still below the level of ambition, In order to arrive at scientific facts, the researchers adopted the comparativ

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Oct 30 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison of regional bond strength of post space of fiber-reinforced post luted with two types of cements at different testing times
...Show More Authors

Back ground: This in vitro study was carried out to investigate the effect of post space regions (coronal, middle and apical), Time and the mode of polymerization (dual, self-cured) of the cements used on the bond strength between translucent fiber post and root dentin by using push-out test. Materials and Methods: Forty eight extracted mandibular first premolars (single root) were instrumented with ProTaper Universal system files (for hand use) and obturated with gutta percha for ProTaper and AH26® root canal sealer following the manufacturer instructions, after 24 hours post space was prepared using FRC postec® plus drills no.3 creating 8 mm depth post space. The prepared samples were randomly divided into two main groups (24 samples ea

... Show More
View Publication Preview PDF