Background: Since the periodontal disease Index of Ramfjord (Ramfjord index) can potentially shorten the examination time by almost half, many studies evaluated Ramfjord teeth in predicting full-mouth periodontal status of an adult population. The aim of this study was to evaluate the benefit of Ramfjord teeth in predicting the full-mouth clinical attachment level of an adult population in patients attending the college of dentistry- Baghdad University. Materials and methods: The study participants were 100 patients with age range from 30-60 years old which represent group zero. The patients were divided into three main groups according to the age of the patients. Group I and group II each of them composed of 30 patients while group III composed of 40 patients. In the first time clinical attachment level (CAL) was measured from the full mouth (FM) and then from the Ramfjord teeth (RT) (teeth number: 16, 21, 24, 36, 41, 44) in all groups. Clinical attachment level (CAL) was measured in millimeters using periodontal probe. Results: The difference in the mean clinical attachment level measured from the full mouth (FM) and Ramfjord teeth (RT) by using paired t - test was non significant in all the groups. Also in all groups the correlation coefficient as well as beta coefficient was high. Conclusion: The high agreement between Ramfjord teeth and full mouth CAL confirm the epidemiological validity of Ramfjord teeth to represent the full mouth.
Background: Adjustment of any premature occlusal contact of any zirconia restoration requires its polishing or glazing in order to restore the smoothness of the restoration. The objective of this in vitro study was to evaluate the effects of different polishing systems and glazing on the surface roughness of full-contour zirconia. Material and methods: Forty disks (diameter: 8 mm, thickness: 6.4 mm) were prepared from pre-sintered full-contoured zirconia block; they were colored and sintered in a high-temperature furnace at 1500ËšC for 8 hours. The specimens were then leveled and finished using grinding and polishing machine and adjusted using diamond disk. The specimens were then randomly divided into four groups (n=10), group I involves
... Show MoreAn experimental work has been conducted on wall attachment fluidics amplifiers, one of them to study the effect of output pressure or load on the amplifier performance. The output load has been simulated as a piston connected to the device output and the piston can be loaded accordingly. The results shows that the output volume flow rate increases as the supply pressure increases under different load and the output pressure remains constant as the supply pressure increases under constant load.
Background: Vitamin D improves innate immunity by enhancing the expression of antimicrobial peptides. The antimicrobial action of cathelicidin is widespread and effective against cariogenic bacteria. This research aimed to investigate the effect of vitamin D deficiency on the level of salivary cathelicidin concerning dental caries experience.
Subjects and Methods: A case-control study was carried out, and the sample was composed of 80 females; the study group involved 40 females with a serum vitamin D concentration of less than 10 ng/ml. In addition to the control group involving 40 females wh
... Show MoreObjective: To evaluate the effect of mouth rinses (Biofresh and ZAK) on the surface micro hardness
of two light cure restorative material (Tetric ceram ivoclar-vivadent) and (3M Z 250) dental
composite.
Methodology: The microhardness values of (sixty) composite specimens were measured at the top
surfaces after 24 hours of immersion in different solutions (Biofresh, Zak mouth wash and distilled
water as control). Comparison done using descriptive statistics (mean, SD, SEM, minimum and
maximum values) and inferential statistics (ANOVA and LSD) test.
Results: The biofresh mouth rinse which has high alcohol containing has less effect on
microhardness of tetric ceram than the zak &distiled water , while the effect
The aims of this reserch is identify evaluate the organizational commitment level of (emotional, standard, continuous) and the level of discipline dimensions (functional duties, professional responsibility and ethics) for medical doctors in Ramadi Teaching Hospital due to their relationship with the organization effectiveness the level of completion work and the importance of the expected results in the field respondent
sample of (50) doctors has from all branches and specialties, including specialist doctors consultants and practitioners as well as branches of residence and senior the most prominent results reached are the emotional and the st
... Show MoreIn most recent studies, long-term retention after orthodontic treatment has been hypothesized that may be necessary to maintain the stability of the dentition and avoid post-treatment changes. The bonded fixed retainer is characterized by its clinical effectiveness, patient acceptance, and lack of patient complaints as compared with a removable retainer. An electronic database (such as PubMed, PubMed Central, Web of Science, Science Direct, Cochrane Library, Scopus, and ResearchGate) has been collected using specific keywords. Of the 152 articles, only randomized clinical trials that investigated different types of fixed retainers or compared fixed with removable retainers were illustrated in tables and included in this review. The
... Show MoreBackground: The present study aimed to determine the influence of the different types of mouth wash on discoloration of different orthodontic ceramic, sapphire brackets and adhesives. Materials and methods: The sample composed of 120 ceramic brackets and 120 sapphire brackets, the brackets were divided according to bond material into three groups of 40 brackets include unbounded brackets, chemically cured (no-mix) bonded brackets and Light cured bonded brackets all these groups were further subdivided according to mouth wash type into three groups with 10 brackets each which include; Listerine, cetrimide, chlorhexidine 0.2%, and one control group which immersed in artificial saliva; then Staining measurements were performed with UV-Visibl
... Show MoreST segment, T wave changes, QT interval changes, and QTc dispersion are among the parameters used to diagnose ischemic heart disease. The increase in the QT dispersion can be caused by myocardial ischemia, among other heart diseases, whereas cardiac diseases such as coronary artery disease (CAD) can be diagnosed by observing an abnormally high QTc dispersion. This study aimed to evaluate the variations in the QTc dispersion (depolarization and repolarization) of surface electrocardiography as a result of percutaneous coronary intervention (PCI) in patients with chronic total occlusion. This study took place in the Iraqi Center for Heart Disease from October 2020 to February 2021. 110 patients who suffered from chronic occlusion of t
... Show More