Background: Dental implants provide a unique treatment modality for the replacement of lost dentition .This is accomplished by the insertion of relatively inert material (a biomaterial) into the soft and hard tissue of the jaws, there by providing support and retention for dental prostheses. Low level laser therapy (LLLT) is an effective tool used to prompt bone repair and modeling post surgery; this has referred to the biostimulation effect of LLLT. The aims of this study were to evaluate the immmunohistochemical expression of vascular endothelial growth factor (VEGF) and transforming growth factor -beta (TGF-β) in experimental and control groups with mechanical test. Materials and Methods: Thirty two adult New Zealand white rabbits used, screw titanium implants inserted in the tibia. The right side is considered as experimental groups and the left side considered as control groups. Low power diode laser (GaAlAs) with wave length (904nm) and (5mW) power applied with the right screw implants. The sample divided into four groups, eight rabbits are sacrificed at four interval 4days, 1 weeks, 2weeks, and 6weeks respectively. immunohistochemical (VEGF&TGF-β), were done for each interval with mechanical test in 2 and 6 weeks . Results: Immunohistochemical findings revealed high positive expression for VEGF and TGF-β in experimental implant in comparison to control one and the acceleration of bone formation and more rapid healing process in the screw implant with laser irradiation than in the control implant. Removal torque test showed dramatic increase with the presence of laser irradiation especially with advancing time. Conclusion: This study was illustrated that the LLLT applications enhance bone formation and increase osseointegration.
RG Majeed, AS Ahmed, Jornal of Al-Muthanna for Agricultural Sciences, 2023
In this work; copper oxide films (CuO) were fabricated by PLD. The films were analyzed by UV-VIS absorption spectra and their thickness by using profilometer. Pulsed Nd:YAG laser was used for prepared CuO thin films under O2 gas environment with varying both pulse energy and annealing temperature. The optical properties of as-grown film such as optical transmittance spectrum, refractive index and energy gap has been measured experimentally and the effects of laser pulse energy and annealing temperature on it were studied. An inverse relationship between energy gap and both annealing temperature and pulse energy was observed.
Background: Implant stability is a mandatory factor for dental implant (DI) osseointegration and long-term success. The aim of this study was to evaluate the effect of implant length, diameter, and recipient jaw on the pre- and post-functional loading stability. Materials and methods: This study included 17 healthy patients with an age range of 24-61 years. Twenty-two DI were inserted into healed extraction sockets to replace missing tooth/ teeth in premolar and molar regions in upper and lower jaws. Implant stability was measured for each implant and was recorded as implant stability quotient (ISQ) immediately (ISQ0), and at 8 (ISQ8) and 12 (ISQ12) weeks postoperatively, as well as post-functional loading (ISQPFL). The pattern of implant
... Show MoreThe research include a pulsed Nd: YAG Laser with (300µs) pulse duration in the TEM00 mode at (1.06µm) wavelength for energies between (0.5-3) J was employed to drill Brass material which is use in industrial applications. The process of drill was assisted by an electric field. This resulted in an increase in the hole aspect ratio by the value (45%) and decrease in the hole taper by the value (25%) of its value under ordinary drilling conditions using the same input energy.
Background: Dental implants act as infrastructure for fixed restoration to look like as a natural tooth. Osseointegration is a biological events and considered as a base for success of dental implant. The aim of this study is to evaluate the bond strength between bone and Ti implant coated with mixture of nano hydroxyapatite-chitosan-collagen compared with Ti implants coated with nano hydroxyapatite implanted in rabbit tibia, after different period of implantation time (two and six weeks) by torque removal test. Material and methods: 36 screws of commercially pure titanium; 8mm in length and 3mm diameter , 18 screws coated with mixture of nano hydroxyapatite-chitosan-collagen and18 screws coated with nano hydroxyapatite by dip coating. St
... Show MoreThe current study aimed to use some bacterial isolates from the local soil of Baghdad city by study the effects of temperature, pH and incubation period on the growth rates of isolated bacteria and choose the optimal conditions for their diversity and for understanding bacterial growth and their requirements for survival and proliferation. This information can be applied to obtain their high growth rate for use in various fields such as agriculture, medicine and environmental sciences in the future. And it used to assess the degree of variation in across bacteria species in pH, temperature and incubation period. A number of local bacterial isolates as
Investments in shares represent an essential component of companies’ assets and a source of profit making resources. These investments are linked to the areas of trading and speculation, which is reflected on their market value, which makes accounting for and evaluating these investments require their own accounting standards, and thus several international standards were issued regarding this as well as a statement of their impact on growth Sustainable, as the research problem is to show the impact of measuring investments in shares according to international accounting and financial reporting standards on the sustainable growth of economic units, the research sample and its reflection on audit procedures. In accordance with i
... Show More