Preferred Language
Articles
/
jbcd-451
Accuracy of spiral computed tomography in evaluation of maxillary sinus septa among dentate and edentulous Iraqi subjects (Comparative study)
...Show More Authors

Background: Presence of maxillary sinus septa has been known to be a complicating factor for sinus elevation procedure and implant placement in posterior maxilla. The maxillary sinuses septa are thin walls of cortical bone inside the sinus. They vary in number, location, and height. This study aimed to discover the accuracy of Spiral Computed Tomographic Scan in evaluation the maxillary sinus septa (prevalence, location, height) in subjects with dentate, partially edentulous and completely edentulous maxilla. Material and method: This study included (267) subjects ranged from (20-70 years), (132) male and (135) female divided into three groups, (97) fully dentate group, (102) partially edentulous group and (68) completely edentulous group who admitted to Spiral Computed Tomography Scan in Al-Karkh General Hospital in Baghdad to have Computed Tomography Scan of the brain and paranasal sinuses for different diagnostic purposes from November 2012 to April 2013. The maxillary sinus septa were evaluated in the axial and sagittal views and the data were subjected to statistical analysis using Statistical Package for Social Sciences version 20. Result: The prevalence rate of septa was 77.3% among fully dentate maxilla sample. Almost the same prevalence rate was obtained in the other two study sample (partially edentulous maxilla 77.5% and completely edentulous maxilla 76.5%).No important or statistically significant difference in prevalence was observed between the three study groups. Age and gender showed no important or statistically significant difference in prevalence rate in each study group, the mean septal height was slightly higher in fully dentate group (7mm) compared to partially edentulous maxilla group (6.2 mm) and completely edentulous maxilla group (6.5 mm). The difference in mean between the 3 groups however was not significant statistically. The rate of septa at floor position was significantly lowest in fully dentate maxilla group (36.1%) compared to partially edentulous maxilla group (52.1%) and completely edentulous maxilla group (53.3%). Conclusion: Spiral Computed Tomography is a precise diagnostic tool for the examination of this zone capable for investigating their location and height during different maxillary sinus surgical procedures. In the posterior maxilla, regardless of type of ridge (atrophy/edentulous or non-atrophy/dentate), the anatomical variation of sinus septa is diverse in its prevalence and location.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 30 2014
Journal Name
International Journal Of Medicine And Pharmaceutical Sciences (ijmps)
YIELDS CALCULATIONS FOR POSITRON EMISSION TOMOGRAPHY (PET) FOR NON-STANDARD RADIONUCLIDE
...Show More Authors

The PET scans provide images that pinpoint the anatomic location of abnormal metabolic activity within the body. A radionuclide suitable for labeling a wide range of radiopharmaceuticals for positron emission tomography imaging is used also for local therapy of tumors. Among the possible methods for cyclotron production of radionuclide used in PET. We investigate the proton irradiation to produce the standard radionuclide (15O, 11C,1 3N, 18F) and some non-standard Radionuclide (76Br,124I,60Cu,66Ga,86Y and 89Zr). The total integral yield based on the main published and approved experimental results of excitation functions were calculated.

Preview PDF
Publication Date
Thu Aug 08 2024
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Novel Technique for Alveolar Ridge Expansion: A Comparative Clinical Study
...Show More Authors

Background: Piezosurgery improved the split approach by making it safer, easier, and less prone to complications when treating extremely atrophic crests. Densah drills, with their unique design, expand the ridge by densifying bone in a reverse, non-cutting mode. Objective: To assess the effectiveness of sagittal piezosurgery, which involves cutting bone to the full implant depth and then expanding it using osseodensification drills. We use this technique to expand narrow alveolar bones and simultaneously place dental implants in the maxillary and mandibular arches. Methods: Fourteen patients received 31 dental implants. The maxillary arch received 19, and the mandible received 12 dental implants. This study will include patients who

... Show More
View Publication Preview PDF
Crossref (1)
Scopus Crossref
Publication Date
Tue Jan 31 2023
Journal Name
Journal Of Legal Sciences
Compensation for Psychological Damage Caused by Negligence - A Comparative Study
...Show More Authors

Psychological damage is one of the damages that can be compensated under the fault of negligence in the framework of English law, where the latter intends to include an enumeration of civil errors on the basis of which liability can be determined, and aims under each of these errors to protect a specific interest (for example, defamation protects Among the damage to reputation and inconvenience are the rights contained on the land), and the same is true for the rest of the other errors. Compensation for psychological damage resulting from negligence has raised problems in cases where the psychological injury is "pure", that is, those that are not accompanied by a physical injury, which required subjecting them to special requirements by the

... Show More
View Publication
Publication Date
Mon Sep 01 2025
Journal Name
Journal Of Engineering
Petrophysical Evaluation by Integrating AI and HFU Methods. A Case Study of the Mishrif Reservoir in Southern Iraq
...Show More Authors

Reservoir quality assessment is important for detecting hydrocarbon-bearing zones and guiding future enhancement strategies. This study presents a detailed petrophysical evaluation of the Mishrif Formation in the Buzurgan Oilfield, which was selected due to its strategic value through its significant remaining reserves which making it an ideal candidate for advanced evaluation techniques. This study aims for shale content, porosity, permeability, water saturation, net to gross, and lithology determination. Well log and core data were used together to establish accurate property estimations. Permeability prediction through conventional methods, like core permeability-porosity correlations, was highly dispersive due to the heterogenei

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Mon May 25 2020
Journal Name
Journal Of Xi'an University Of Architecture & Technology
Iraqi Virtual Science Library (IVSL)): A field study of Iraqi researcher’s viewpoint
...Show More Authors

The aim of the research is to shed light on the stages of developing the Iraqi virtual science Library(IVSL) project, and to define its distinctive role in providing all kinds of electronic resources to researchers from professors and graduate students, to identify its contents , the entry interfaces and applications of use, and provide them through electronic portals to publishing houses, research institutions and international universities, The research sample included the teaching staff and researchers participating in educational qualification courses at the Continuing Education Center at the University of Baghdad, The research population and its sample consisted of the category of (IVSL) users, and its sample (387) users. Analysis meth

... Show More
View Publication Preview PDF
Publication Date
Fri Apr 30 2021
Journal Name
Al-kindy College Medical Journal
Slump Test versus Straight Leg Raise Test in the Diagnosing of Lumbar Disc Herniation: A Prospective Comparative Study
...Show More Authors

Background: The clinical examination is one of the best suitable methods for diagnosis of low backache. Backache is one disease that the signs, clinical examination finding, and the results on imaging modalities not always related. The straight leg raising (SLR) and slump tests, can be used for diagnosis of lumber disc herniation.

Objectives: To compare the result of the slump test and SLR test in the diagnosis of lumber disc herniation.

Subjects and Methods: A prospective comparative study conducts on 280 patients in Al-Kindy teaching and private clinics complaints of backache, aging between 18-70 years old with acute or recurrent backache, sciatica pai

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Apr 30 2021
Journal Name
Al-kindy College Medical Journal
Slump Test versus Straight Leg Raise Test in the Diagnosing of Lumbar Disc Herniation: A Prospective Comparative Study
...Show More Authors

Background: The clinical examination is one of the best suitable methods for diagnosis of low backache. Backache is one disease that the signs, clinical examination finding, and the results on imaging modalities not always related. The straight leg raising (SLR) and slump tests, can be used for diagnosis of lumber disc herniation. Objectives: To compare the result of the slump test and SLR test in the diagnosis of lumber disc herniation. Subjects and Methods: A prospective comparative study conducts on 280 patients in Al-Kindy teaching and private clinics complaints of backache, aging between 18-70 years old with acute or recurrent backache, sciatica pain, or low back and sciatica pain for last 12 weeks, while patients

... Show More
Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Jun 01 2018
Journal Name
International Journal Of Health Sciences
Molecular assessment of some cardiovascular genetic risk factors among Iraqi patients with ischemic heart diseases
...Show More Authors

Abstract Objective: The underlying molecular basis of ischemic heart diseases (IHDs) has not yet been studied among Iraqi people. This study determined the frequency and types of some cardiovascular genetic risk factors among Iraqi patients with IHDs. Methods: This is a cross-sectional study recruiting 56 patients with acute IHD during a 2-month period excluding patients >50 years and patients with documented hyperlipidemia. Their ages ranged between 18 and 50 years; males were 54 and females were only 2. Peripheral blood samples were aspirated from all patients for troponin I and DNA testing. Molecular analysis to detect 12 common cardiovascular genetic risk factors using CVD StripAssay® (ViennaLab Diagnostics GmbH, Austria) was performed

... Show More
View Publication
Publication Date
Tue Mar 28 2023
Journal Name
International Journal Of Dentistry
The Effect of Different Obturation Techniques in Primary Teeth on the Apical Microleakage using Endoflas: A Comparative In Vitro Study
...Show More Authors

Objectives. This study was carried out to quantitatively evaluate and compare the sealing ability of Endoflas by using differentobturation techniques. Materials and Methods. After 42 extracted primary maxillary incisors and canines were decoronated, theircanals were instrumented with K files of size ranging from #15 to #50. In accordance with the obturation technique, the sampleswere divided into three experimental groups, namely, group I: endodontic pressure syringe, group II: modified disposable syringe,and group III: reamer technique, and two control groups. Dye extraction method was used for leakage evaluation. Data wereanalyzed using one-way ANOVA and Dunnett’s T3 post hoc tests. The level of significance was set at p<0:05. Results.

... Show More
View Publication
Crossref (5)
Crossref
Publication Date
Wed Aug 19 2020
Journal Name
Applied Water Science
Spiral path three phase fluidized bed reactor for treating wastewater contaminated with engine oil
...Show More Authors
Abstract<p>In this study, a new type of circulating three-phase fluidized bed reactor was conducted by adding a spiral path and was named as spiral three-phase fluidized bed reactor (TPFB-S) to investigate the possibility for removing engine oil (virgin and waste form) from synthetic wastewater by using Ricinus communis (RC) leaves natural and activated by KOH. The biosorption process was conducted by changing particle diameter in the range 150–300 and 300–600 µm, liquid flow rate in the range 2.5–4.5 L/min and gas flow rate in range of 0–1 L/min, while other parameters initial oil emulsion concentration, pH, adsorbent concentration, agitation speed and contact time were kept constant at 2000 mg/L, 2,</p> ... Show More
View Publication
Scopus (14)
Crossref (11)
Scopus Clarivate Crossref