Preferred Language
Articles
/
jbcd-451
Accuracy of spiral computed tomography in evaluation of maxillary sinus septa among dentate and edentulous Iraqi subjects (Comparative study)
...Show More Authors

Background: Presence of maxillary sinus septa has been known to be a complicating factor for sinus elevation procedure and implant placement in posterior maxilla. The maxillary sinuses septa are thin walls of cortical bone inside the sinus. They vary in number, location, and height. This study aimed to discover the accuracy of Spiral Computed Tomographic Scan in evaluation the maxillary sinus septa (prevalence, location, height) in subjects with dentate, partially edentulous and completely edentulous maxilla. Material and method: This study included (267) subjects ranged from (20-70 years), (132) male and (135) female divided into three groups, (97) fully dentate group, (102) partially edentulous group and (68) completely edentulous group who admitted to Spiral Computed Tomography Scan in Al-Karkh General Hospital in Baghdad to have Computed Tomography Scan of the brain and paranasal sinuses for different diagnostic purposes from November 2012 to April 2013. The maxillary sinus septa were evaluated in the axial and sagittal views and the data were subjected to statistical analysis using Statistical Package for Social Sciences version 20. Result: The prevalence rate of septa was 77.3% among fully dentate maxilla sample. Almost the same prevalence rate was obtained in the other two study sample (partially edentulous maxilla 77.5% and completely edentulous maxilla 76.5%).No important or statistically significant difference in prevalence was observed between the three study groups. Age and gender showed no important or statistically significant difference in prevalence rate in each study group, the mean septal height was slightly higher in fully dentate group (7mm) compared to partially edentulous maxilla group (6.2 mm) and completely edentulous maxilla group (6.5 mm). The difference in mean between the 3 groups however was not significant statistically. The rate of septa at floor position was significantly lowest in fully dentate maxilla group (36.1%) compared to partially edentulous maxilla group (52.1%) and completely edentulous maxilla group (53.3%). Conclusion: Spiral Computed Tomography is a precise diagnostic tool for the examination of this zone capable for investigating their location and height during different maxillary sinus surgical procedures. In the posterior maxilla, regardless of type of ridge (atrophy/edentulous or non-atrophy/dentate), the anatomical variation of sinus septa is diverse in its prevalence and location.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jun 30 2006
Journal Name
Al-kindy College Medical Journal
The Use of Spiral Computerized Tomography in the Diagnosis of Middle –Third Facial Fractures as Compared to Plain Radiography
...Show More Authors

Background: Trauma is one of the most common
clinical problems that confront the maxillofacial
surgeon and radiologist alike. Middle third facial
fractures are diagnosed primarily on the bases of
clinical examination and plain radiographs than can
result in much preoperative speculation.
Objective: To assess the advantages of spiral
computerized tomography over conventional
radiography in the pre-surgical evaluation of middle
third facial fractures.
Methods: Thirty patients with thirty-eight facial
fractures were studied, all patients were examined
clinically, by plain radiography and then by spiral CT.
Results: Of the 38 middle-third fractures, 16
(42.1%) were zygomatic fractures, 8 (21.1%) were

... Show More
View Publication Preview PDF
Publication Date
Fri Apr 04 2025
Journal Name
Journal Of Baghdad College Of Dentistry
An Assessment of Sagittal Condylar Position of TMJ Dysfunction in Centric Occlusion by Using Cone Beam Computed Tomography
...Show More Authors

Background: Temporomandibular joint (TMJ) is a compound articulation formed from the articular surfaces of the temporal bone and the mandibular condyle.CBCT imaging of TMJ is that it allows accurate measurements of the volume and surface of the condyle. The aim of the study is to assess the sagittal position of mandibular condyle in patients with temporomandibulardysfunction using Cone Beam Computed Tomography in centric occlusion. Materials and Methods: CBCT images for all patients were obtained in an upright position using New Tom Giano CBCT with different field of view (11 x 8), (11 x 5), and (8 x 8) and exposure factors was changed accordingly using NNT version 5.1 software for sagittal reconstruction, anterior, superior and posterior

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Sep 01 2018
Journal Name
J Indian Soc Periodontol.
Osteoporosis effect on posterior mandible in preimplanted area for postmenopausal females using cone-beam computed tomography
...Show More Authors

Scopus (2)
Scopus
Publication Date
Fri Apr 04 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Computed tomography bone density in Hounsfield units at dental implant receiving sites in different regions of the jaw bone
...Show More Authors

Background: Determination of local bone mineral density (BMD) with cortical thickness and bone height may offer a comprehensive description of the bone the surgeon will encounter when he or she actually sets the implant. Quantitative computed tomography (CT) (i.e., quantitative interpretation of values derived from Hounsfield units with a suitable calibration procedure) is the modality of choice to determine BMD. The aim of the present clinical study is to determine the local bone density in dental implant recipient sites using computerized tomography. Material and method: The sample consisted of (72) Iraqi patients whom referred to Al-Kharkh General hospital, Spiral CT scan Department for bone quality and quantity assessment after one wee

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Investigation and Comparative Study Among Various Methods of Contraception Used in Erbil City
...Show More Authors

The objective of this study was to investigate and compare among five different methods of contraception including combined oral contraceptive pills (COC), Depot medroxyprogesterone acetate (DMPA), copper Intrauterine contraceptive device (IUCD), vaginal spermicides and male condom used in Hawler City through estimate of their effect, relative failure rate, percentage of use, adherence and compliance and adverse effects of each contraceptive method. In order to reach to these aims, a retrospective study was conducted in Hawler City in Azadi Health Care Center over a period of 6 months from 22th November, 2010 to 15th May, 2011 during which data collection and subjects follow up for 3 months had been achieved. A conv

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 15 2019
Journal Name
Journal Of Ideas In Health
Evaluation of self-medication among Iraqi pharmacy students
...Show More Authors

Background: Practicing self-medication is common and a worrisome issue because of irrational drug use. This study aimed to evaluate self-medication knowledge and views among the final year pharmacy students in Iraq.  Methods: A cross-sectional descriptive study was conducted from December 2018 to January 2019. A pre-validated and self-administered questionnaire was recruited to survey pharmacy students at the University of Baghdad and Al-Rafedain University College. The Statistical Package for the Social Sciences version 20 (SPSS v. 20) software used to save and analyze the data. Results expressed as numbers and percentages. Results:  A total of 344 students (response rate: 94.24%) with a mean age of 22.10 years includ

... Show More
View Publication
Crossref (3)
Crossref
Publication Date
Fri Apr 04 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Thickness of Buccal Bone at Various Sites of the Mandible and Its Clinical Significance in MonocorticalScrews Placement Using Multi-Slice Computed Tomography
...Show More Authors

Background:Open reduction and internal fixation (ORIF) of using miniplates and screws is the treatment of choice of mandibular fractures. It is important to know both: the region where the bone providesafirm anchorage, andthe topography of the dental apices and inferior alveolar nerve to avoiddamaging them when inserting the screw. The aim of this study is to determine the thickness of buccal cortical plate and that of buccal bone at the parasymphysis and mandibular body, thereby determining the area that provide afirm anchorage and the maximum length of mono-cortical screws that can be safely placed in these regions without injuring the tooth roots or mandibular nerve. Materials and Methods:The sample of the present study was 110 Iraqi sub

... Show More
View Publication Preview PDF
Publication Date
Tue Nov 01 2016
Journal Name
Journal Of Economics And Administrative Sciences
Using Public and Private Cloud Computing in developing the Evaluation System of annual employees' performance at Iraqi Universities: A comparative study
...Show More Authors

Abstract

Business organizations are using the technological innovations like cloud computing (CC) as a developmental platform in order to improve the performance of their information systems. In that context, our paper discusses know-how in employing the public and private CC to serve as platforms to develop the evaluation system of annual employees' performance (ESAEP) at Iraqi universities. Therefore, we ask the paper question which is Is it possible to adopt the innovative solutions of ICTs (Like: public and private CC) for finding the developmental vision about management information systems at business organizations?”. In addition, the paper aim

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Dec 20 2021
Journal Name
Journal Of Craniofacial Surgery
The Effect of Bone Density Measured by Cone Beam Computed Tomography and Implant Dimensions on the Stability of Dental Implants
...Show More Authors

Abstract: The aim of this study was to evaluate the effect of bone density value in Hounsfield unit derived from cone beam computed tomography (CBCT), and implant dimensions in relation to implant stability parameters namely the resonance frequency analysis and the insertion torque (IT) value. It included 24 patients who received 42 dental implants (DI). The bone density of the planned implant site was preoperatively measured using cone beam computed tomography. The implant stability was measured using Osstell implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. The IT value was categorized as 35 N/cm or > 35 N/cm. The mean (standard deviation) primary stability was 79.58 (5.27) ISQ,

... Show More
View Publication
Scopus (10)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Sex Variations by Linear Measurements of Palatal Bones and Skull Base Using 3D Reconstructed Computed Tomographic Scan among Iraqi Sample
...Show More Authors

Background: The skull base and the hard palate contain many anatomical features that make them rich in information which are useful in sex differentiation; in addition to that they have the ability to resist the hardest environmental conditions that support them in making sex differentiation. Three dimensional computed tomographic techniques has important role in differentiation between sex since it offers images with very accurate data and details of all anatomical structures with high resolution. This study was made to study sex variations among Iraqi sample by craniometric linear measurements of the hard palate and the skull base using 3D reconstructed Computed Tomographic scan. Materials and methods: This study composed of 100 Iraqi su

... Show More
View Publication Preview PDF
Crossref