Preferred Language
Articles
/
jbcd-448
The effect of plasma treatment on shear bond strength of soft denture liner with two different types of denture base material (heat cure and light cure)
...Show More Authors

Background: In this study we evaluate the effect of plasma treatment (oxygen and argon) gas in two different exposure times on the surface of heat cure and light cure acrylic resin. Materials and method: 100 specimens of heat cure and light cure acrylic resin were fabricated. The measurements of the samples were (75mm, 25mm and 4.5mm) length, width and depth respectively with stopper of 3mm depth. Two types of gas used oxygen and argon in (5,10) min by using (DC-glow discharge plasma device) then we apply cold cure soft lining material, with the help of Instron machine we test the shear stress value. Results: A highly significant effect after argon and oxygen gases treatment in both 5 and 10 min exposure times on shear bond strength to soft liner in heat cure denture base material. Conclusion: In this study we found that the exposure of heat cure acrylic resin to plasma gases (argon and oxygen) increase the shear bond strength (SBS) values significantly.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Apr 15 2010
Journal Name
International Journal Of Poultry Science
Effect of Dietary Supplementation with Different Oils on Productive and Reproductive Performance of Quail
...Show More Authors

View Publication
Scopus (23)
Crossref (14)
Scopus Crossref
Publication Date
Sun Jun 30 2013
Journal Name
Al-khwarizmi Engineering Journal
Effects of Different Types of Fillers on Dry Wear Characteristics of Carbon-Epoxy Composite
...Show More Authors

Experimental investigations had been done in this research to demonstrate the effect of carbon fiber and Ceramic fillers contents on the tribological behaviour of (15% volume fraction) carbon-epoxy composite system under varying volume fraction, load, time and sliding distance. The wear resistance were investigated according to ASTM G99-05standard using pin on disc machine to present the composite tribological behaviour. The influence of three ceramic fillers, granite, perlite and calcium carbonate (CaCO3), on the wear of the carbon fabric reinforced epoxy composites under dry sliding conditions has been investigated. The effect of variants in volume fraction, applied load, time and sliding distance on the wear behaviour of po

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 29 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
The Study the Effect of Ultraviolet on the Compression and Hardness Property for Hybrid Material
...Show More Authors

The study was carried out by reinforcing the resin matrix material

which was (Epoxy- Ep828) by useing Kevlar fibers and glass fibers type (E-gl ass) both or them in the form of woven roving and poly propylene tlbcrs  in  the form chopped  strand  mats.  wi th (30%)  volume  fraction. Some mechan i cal  properties of the were prepared composite specimens U ltraviolet   radiation  were  stuied   after   being  subjected  to  different weathering conditi ons i ncluded. Compression and hardness testing were carried out using Briel! method so as to compare between composite behavior i n the environments previously mentioned .

 <

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 20 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of different oral hygiene regimens on the quantity of cariogenic plaque on orthodontic bands with different attachments (A clinical photographic study)
...Show More Authors

Background: Fixed orthodontic appliances impede the maintenance of oral hygiene and result in plaque accumulation leads to enamel demineralization caused by acids produced by bacteria. Studies on plaque control strategies in orthodontic populations are limited. This might be caused by difficulties in the quantitative evaluation of dental plaque because the teeth have various levels of bracket coverage, and different tooth sizes and malocclusions, making the traditional categorical indices complex. The present study aims to evaluate the effect of different hygiene protocols on plaque quantity on bands with different attachments. Materials and method: Twenty patients had four bands within the orthodontic appliance. Then randomly divided into

... Show More
View Publication Preview PDF
Publication Date
Sat Apr 06 2024
Journal Name
Indian Journal Of Physics
Investigating the effect of alternating voltage frequency on plasma jet parameters
...Show More Authors

View Publication
Scopus
Publication Date
Sat Jan 01 2022
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees21gr
The effect of plasma jet-generated gold nanoparticles on liver functions
...Show More Authors

In this study, gold nanoparticles (AuNPs) were synthesized using a plasma jet system at different exposure times. Using ultraviolet, visible spectra, X-ray diffraction, the nanoparticles were characterized (XRD). A Plasmon surface resonance concentrated at 530, 540, and 533 nm for the prepared AuNPs. The pattern of XRD showed that the extreme peaks of the film reflect crystalline existence. The face-centered cubic structure of the gold nanoparticles was prepared for all samples, with an average crystallite size of 25-40 nm. The effect of AuNPs in vivo on liver function levels was measured. For all doses, we notice an increase in the ranks of liver function in the blood during the period of dosing, and it begins to decrease when the dosi

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Jun 04 2018
Journal Name
Baghdad Science Journal
The Effect of Gas Flow on Plasma Parameters Induced by Microwave
...Show More Authors

In this paper, construction microwaves induced plasma jet(MIPJ) system. This system was used to produce a non-thermal plasma jet at atmospheric pressure, at standard frequency of 2.45 GHz and microwave power of 800 W. The working gas Argon (Ar) was supplied to flow through the torch with adjustable flow rate by using flow meter, to diagnose microwave plasma optical emission spectroscopy(OES) was used to measure the important plasma parameters such as electron temperature (Te), residence time (Rt), plasma frequency (?pe), collisional skin depth (?), plasma conductivity (?dc), Debye length(?D). Also, the density of the plasma electron is calculated with the use of Stark broadened profiles

View Publication Preview PDF
Scopus (18)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Sun Apr 20 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Platelet-Rich Plasma on Osseointegration Period of Dental Implants
...Show More Authors

Background: The preparation of Platelet-rich plasma (PRP) is minimally invasive way, simple, low cost to obtain natural autologous growth factors and is now being widely used in different fields of medicine for its ability to increase the regeneration potential of tissue. The aim of this study was to investigate the effect of local application of autologous PRP gel on acceleration rate of osseointegration period by clinical assessment accomplished by determining the changes in implant stability during 3 months healing period using resonance frequency analysis (RFA). Materials and methods: A total of 28 dental implants were inserted in edentulous maxillae or mandibles of 13 patients using a split mouth design, i.e. each patient was received

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Kuwait Journal Of Science
The effect of magnetic field variations on the spectral properties of tornado plasma
...Show More Authors

At atmospheric pressure and at a frequency of 9.1 kHz, a constructed magnetically stabilized tornado gliding arc discharge (MSGAD) system was utilized in this study to generate a non-thermal plasma with an alternating voltage source from 2,4,6,8 to 10 kV. Argon gas was used to generate the arc plasma with an adjustable flow rate using a flow meter regulator to stabilize the gas flow rate to 2 L/min. A gliding plasma discharge is achieved by a magnetic field for the purpose of a planned investigation. The influence of the magnetically stabilized tornado gliding arc discharge parameters such as magnetic field and applied voltage on microscopic tornado plasma parameters was studied. The electron temperature1was measured using a Boltzmann plot

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Apr 07 2013
Journal Name
Journal Of Educational And Psychological Researches
Two Types of Personality and Achievement Motivation among University Teaching Staff Members
...Show More Authors

    Research aimed to:1- Be acquainted to the two types of personality A,B with the members of the teaching staff of Anbar university 2- The level of the motivational achievement among the teaching staff  3- The level of motivational achievement  of the teaching staff  of( A,B). 4- Differences of the abstract implications of A,B type  5- The relationship between A and B and the motivational achievement.

  Research Tools: the researchers  followed  measure  A, B type of  Howard Glaser  1978,and   measure  of Achievement Motivation for Mansoorm1986.

   The Result showed: 1. A tendency of the t

... Show More
View Publication Preview PDF