Background: It has been well known that the success of mandibular implant- retained overdenture heavily depends on initial stability, retention and long term osseointegration this is might be due to optimal stresses distribution in surrounding bones. Types of mandibular implant- retained overdenture anchorage system and number of dental implants play an important role in stresses distribution at the implant-bone interface. It is necessary to keep the stresses below the physiologic tolerance level of the bone .since. And it is difficult to measure these stresses around bone in vivo. In the present study, finite element analysis used to study the stresses distribution around dental implant supporting Mandible implant retained overdenture Materials and methods: Eight models were constructed including four designs of anchorage system (ball-cup, ball-O Ring, bar without distal extension and bar with distal extension).The first group of models were supported by four dental implant and second group of models were supported by two dental implant only. Models constructed from the data obtained directly from patient The contour of bone was obtained from C.T scan image of patient, then data transferred to ANSYS program for modeling then load applied and solve the equation by the program, Specified nodes were selected at the rings of crestal bone (cortical bone) and cortical cancellous interface around each dental implant and fixed for all models to monitor the stress change in that regions of different design of MIR-OD.. After load application, Specified nodes were selected at the rings of crestal bone (cortical bone) and cortical cancellous interface around each dental implant and fixed for all models to monitor the stress change in that regions of different design of MIR-OD . Results: In the present study the stress distribution and maximum stresses value around dental implant had a relationship to the number of dental implant. , The result appeared that the maximum stresses and means of stresses value was lower in the first group of models (which was supported through the use four dental implant) than the second group of models (which was supported through the use of two dental implant only). For the first group of models the maximum stresses value around mesial implant was11.67, 10.51, 10.98 and 10.72 Mpa, while the maximum stresses around distal implant was 21.33, 18.51, 18.86, and17.56 Mpa for models 1,2,3 and 4respectively ,and the stresses around implant supporting second group of models was 22.52, 22.16, 20.51 and 19.60 Mpa for models 5,6,7and8 respectively .Statistical analyses of means value appeared that there was statistically significant difference in stresses means value around implant of the second group with that’s values around mesial and distal implant supporting first group of model . Regarding the result of both ball and bar system, it has been demonstrated that stress was greater with ball attachment and MIR-OD supported by the use of four dental implants and anchored by bar attachments with distal extension gives the minimum values of stresses than the rest models. Also the results show that higher stresses value was appeared at the cortical bone ring surrounding dental implant especially the distal implant nearest to the free end extension area. Also it was appeared that the best model was Mandible implant- retained overdenture that’s anchored by bar with distal extension and support by four dental implant. Conclusions: Bar-clips with distal extension mode of attachment considered the best type in producing the least stresses around dental implant regardless number of dental implant used.
The paper include studies the effect of solvent of dye doped in polymeric laser sample which manufactured in primo press way, which is used as an active (R6G) tunable dye lasers. The remarks show that, when the viscosity of the solvent (from Pure Water to Ethanol), for the same concentration and thickness of the performance polymeric sample is increased, the absorption spectrum is shifts towards the long wave length (red shift), & towards short wave length (blue shift) for fluorescence spectrum, also increased the quantum fluorescence yield. The best result we obtained for the quantum fluorescence yield is (0.882) with thickness (0.25mm) in Ethanol solvent in concentration (2*10-3mole/liter), while when we used the Pure Water as a solvent,
... Show MoreThe aim of this study is to investigate the behavior of composite castellated beam in which the concrete slab and steel beam connected together with headed studs shear connectors. Four simply supported composite beams with various degree of castellation were tested under two point static loads. One of these beams was built up using standard steel beam, i.e. without web openings, to be a reference beam. The other three beams were fabricated from the same steel I-section with various three castellation ratios, (25, 35, and 45) %. In all beams the concrete slab has the same section and properties. Deflection at mid span of all beams was measured at each 10 kN load increment. The test results show that the castellation process leads to
... Show MoreBN RASHİD, 2023
The lower Cretaceous sandstones of Zubair and Nahr Umr formations are the main producing reservoirs in Subba oilfield in southern Iraq. Key differences in their petrophysical and depositional attributes exist affecting their reservoir characteristics. The evaluation of well logs and core porosity-permeability data show better reservoir properties in Nahr Formation. The Litho-saturation logs indicate greater thickness of oil-saturated reservoir units for Nahr Unr Formation associated with lower values of shale volume, and higher values of effective porosity. In addition, higher values of permeability for Nahr Umr Formation is suggested by applying porosity-irreducible water saturation cross plot. The reducing reservoir quality of Zub
... Show MoreThe present work introduces, external morphological study of the leafhopper Neoalitarus
fenestratus Herrich-Schäeffer (Deltocephalinae:Oposiini), particularly the male genitalia
which were dissected and illustrated.
The flexibility of interaction between the movement of macroeconomic variables that affect and are affected by the balance of payments, especially the movement of the current account, implies a perception of the maturity of economic development and what the theory assumes from the launch of a wide range of economic movement that varies in the degree of its influence according to the level of economic development and the vitality of the internal/external overlap relations through the assumed response to the movement of the macroeconomic variables. On this basis, it is possible to estimate the soundness and rationality of the economic decision taken that takes into account the required reciprocal repercussions between the current a
... Show MoreColorectal cancer (CRC) is the most common disease and cause of death globally. The aim of the study is investigation and detection of some bacterial interfering with CRC occurrence and progression. The study conducted between September 2022 till February 2023, a total of 50 specimens were collected from confirmed CRC patients. In addition, 50 stool specimens were collected from Healthy volunteers, considers as control group. Isolation and identification of bacteria in all collected specimens were done by using cultural and differential media (blood agar, macconkey agar and Pfizer agar), as well as the VITEK- 2 compact system. The bacterial species, in the specimens of control were ( Escherichia coli 50 (86.20%), Klebsiella Pneumoni
... Show MoreCarnosol, a phenolic diterpene, is one of the effective anticancer agents naturally occurring in rosemary, sage, parsley, and oregano. The chemoresistance problem increased with the routinely used chemotherapy. Therefore, the efforts to find a substitute with safe and low cost have become crucial worldwide. The current study attempts to inspect the anticancer molecular mechanisms of Carnosol on modulating up- and down- regulation of multiple genetic carcinogenesis pathways. The cytotoxicity of Carnosol on Hela cells was evaluated by MTS assay. Flow cytometry was used to assess apoptosis and cell cycle arrest. The apoptotic morphological changes were obvious by dual apoptosis assay. The differential gene expression after treatment wi
... Show More