Preferred Language
Articles
/
jbcd-446
Finite element stress analysis study for stresses around mandibular implant retained overdenture MIR-OD
...Show More Authors

Background: It has been well known that the success of mandibular implant- retained overdenture heavily depends on initial stability, retention and long term osseointegration this is might be due to optimal stresses distribution in surrounding bones. Types of mandibular implant- retained overdenture anchorage system and number of dental implants play an important role in stresses distribution at the implant-bone interface. It is necessary to keep the stresses below the physiologic tolerance level of the bone .since. And it is difficult to measure these stresses around bone in vivo. In the present study, finite element analysis used to study the stresses distribution around dental implant supporting Mandible implant retained overdenture Materials and methods: Eight models were constructed including four designs of anchorage system (ball-cup, ball-O Ring, bar without distal extension and bar with distal extension).The first group of models were supported by four dental implant and second group of models were supported by two dental implant only. Models constructed from the data obtained directly from patient The contour of bone was obtained from C.T scan image of patient, then data transferred to ANSYS program for modeling then load applied and solve the equation by the program, Specified nodes were selected at the rings of crestal bone (cortical bone) and cortical cancellous interface around each dental implant and fixed for all models to monitor the stress change in that regions of different design of MIR-OD.. After load application, Specified nodes were selected at the rings of crestal bone (cortical bone) and cortical cancellous interface around each dental implant and fixed for all models to monitor the stress change in that regions of different design of MIR-OD . Results: In the present study the stress distribution and maximum stresses value around dental implant had a relationship to the number of dental implant. , The result appeared that the maximum stresses and means of stresses value was lower in the first group of models (which was supported through the use four dental implant) than the second group of models (which was supported through the use of two dental implant only). For the first group of models the maximum stresses value around mesial implant was11.67, 10.51, 10.98 and 10.72 Mpa, while the maximum stresses around distal implant was 21.33, 18.51, 18.86, and17.56 Mpa for models 1,2,3 and 4respectively ,and the stresses around implant supporting second group of models was 22.52, 22.16, 20.51 and 19.60 Mpa for models 5,6,7and8 respectively .Statistical analyses of means value appeared that there was statistically significant difference in stresses means value around implant of the second group with that’s values around mesial and distal implant supporting first group of model . Regarding the result of both ball and bar system, it has been demonstrated that stress was greater with ball attachment and MIR-OD supported by the use of four dental implants and anchored by bar attachments with distal extension gives the minimum values of stresses than the rest models. Also the results show that higher stresses value was appeared at the cortical bone ring surrounding dental implant especially the distal implant nearest to the free end extension area. Also it was appeared that the best model was Mandible implant- retained overdenture that’s anchored by bar with distal extension and support by four dental implant. Conclusions: Bar-clips with distal extension mode of attachment considered the best type in producing the least stresses around dental implant regardless number of dental implant used.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Aug 01 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Cranial base morphology in different skeletal classes (A cross-sectional lateral cephalometric study)
...Show More Authors

Background: It was stated in scientific literatures that the entire craniofacial complex is influenced by the growth of the cranial base structures. Nevertheless, many times this is not the case, and this point is subject to great controversy so the aim of this study is to evaluate the possible differences in cranial base shape and flexure between different skeletal classes for both genders and to investigate any possible correlation between cranial base variables and other skeletal base variables. Materials and Methods: The sample include 75 lateral cephalometric radiographs of Iraqi adults aged between 18-25 years (39 males, 36 females), collected from patients and undergraduate students in the orthodontic department of College of Dentist

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 01 2017
Journal Name
كلية التربية للبنات
The rights of orphans in the Old Testament and Islam, a Comparative Study
...Show More Authors

Allah Almighty has aggrandized the position of orphans and elevated their status in the society and has given the graces for those who sponsor the orphan and care for and protecting them, even those who rub their heads. The divine care is manifested in the verses of the Holy Bible and the Holy Quran. Therefore, the whole world cared for the orphan, and called for the rights of the orphans in the conferences and the channels. But all that was little effort that does not meet what the orphan need and some were only ink on paper that were not applied. All that mentioned above is necessary in dealing with the study (the rights of orphans in the Old Testament and Islam, a Comparative Study). The study was divided into a Preface and four inquirie

... Show More
Preview PDF
Publication Date
Sun Jun 30 2013
Journal Name
Al-kindy College Medical Journal
Clinical and Doppler Study of Restrictive Filling Pattern in Patients with Dilated Cardiomyopathy
...Show More Authors

Background: Dilated cardiomyopathy (DCM) is a well-recognized cause of cardiovascular morbidity and mortality.Objectives: To evaluate the prognostic implications of the restrictive left ventricular filling pattern (RFP) in dilated cardiomyopathy.Methods: Patients with DCM admitted to Ibn AL-Bitar Hospital for Cardiac Surgery, Baghdad-Iraq, from May 2006 to August 2008, underwent a full clinical evaluation and Doppler echocardiography study. Patients were classified into three groups: Group I had persistent restrictive filling pattern; Group II had reversible restrictive filling pattern; and Group III had nonrestrictive filling pattern. Results: The current study was conducted on a total number of 80 patients with DCM, fifty (62.5 %) were

... Show More
View Publication Preview PDF
Publication Date
Fri Jun 01 2018
Journal Name
مجلة مدينة العلم الجامعة
External Morphological Study of Tribolium castaneum (Herbst , 1797) (Coleoptera : Tenebrionidae) mid of Iraq
...Show More Authors

The study included the description of external body parts and the male genitalia for the male of rusty flour beetle Tribolium castaneum (Herbst,1797) and the studied was supported by illustrations

Publication Date
Sun Jun 03 2012
Journal Name
Baghdad Science Journal
Comparative study of creep and fatigue crack growth in Poly (Vinyl chloride) pipe
...Show More Authors

The Rate theory of crack growth in PVC pipe has been studied for creep and fatigue crack propagation. Rate theory function parameters, (RTFP), were estimated theoretically from exponential function parameters, (EFP), to experimental data of crack velocity versus stress intensity factor ,(V-K) diagram, to creep crack propagation . Also (RTFP) were estimated theoretically from (EFP) to experimental data of (V-?K) diagram to fatigue crack propagation. Temperature effect with (RTFP) was discussed. Crack velocity function denoted with stress intensity factor and temperature degrees has been determined to fatigue and creep crack propagation theoretically and comparative results this function with experimental data of (V-K or ?K) diagram .

View Publication Preview PDF
Crossref
Publication Date
Mon Oct 01 2012
Journal Name
Iraqi Journal Of Physics
Comparison study of some mechanical properties of micro and nano silica EP composites
...Show More Authors

The effect of micro-and nano silica particles (silica SiO2 (100 μm), Fused silica (12nm)) on some mechanical properties of epoxy resin was investigated (Young's modulus, Flexural strength). The micro-and nano composites were prepared by using three steps process with different volume fraction of micro-and nano particles (1, 2, 3, 4, 5, 7, 10, 15, and 20 vol. %). Flexural strength and Young's modulus of nano composites were increased at low volume fraction (max. enhancement at 4 vol.% ). However at higher volume fraction both Young's modulus and flexural strength decrease. Moreover, above, the mechanical properties are enhanced more than that of neat epoxy resin. The flexural strength decreases with increasing the volume fraction of micr

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 01 2015
Journal Name
Basrah Journal Of Veterinary Research
Prenatal Histological study of the limbs bone onset development in Guinea pig (CaviaCutleri)
...Show More Authors

View Publication
Publication Date
Tue Feb 12 2019
Journal Name
Iraqi Journal Of Laser
Effects of Ho: YAG Laser (2100nm) in Prostate Tissue: An in vitro Study
...Show More Authors

Benign prostate hyperplasia (BPH), non-cancerous enlargement of prostate, is the most prevalent disease entity in elderly men. BPH affects 40% of men after the age of 60year worldwide. BPH causes problems for patients with significant lower urinary tract obstructive symptoms, if not responding to medical therapy, surgical intervention is instituted. One method of the treatment of symptomatic BPH is laser prostatectomy. The understanding of tissue effects by laser radiation is very important for the safe clinical application of laser. Objective: study the 2100 nm Ho: YAG laser gross tissue effects in the prostate at different laser dose settings in an vitro model prostate tissue samples harvested from same specimen of open surgery prostat

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 20 2022
Journal Name
Webology
The Effect of Strategic Information System in Global Marketing Channel: A Case Study
...Show More Authors

The research dealt with the issue of strategic information systems and its impact on the global marketing channel. As the research aims to know the strategic information systems used in the cement company. Which support the senior management in supporting decisions taken in the process of global orientation and moving to foreign markets by choosing the marketing channel that will suit the company. Product and competition with it. With other companies' products. The problem of the study focused on how to move to global markets, and any marketing channel that can be followed to move the cement product globally, what are the strategic information systems used in the company and how will it contribute to supporting senior management dec

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 06 2018
Journal Name
American Institute Of Physics
Synthesis and characterization study of n-Bi2O3/p-Si heterojunction dependence on thickness
...Show More Authors

Abstract. In this work, Bi2O3 was deposited as a thin film of different thickness (400, 500, and 600 ±20 nm) by using thermal oxidation at 573 K with ambient oxygen of evaporated bismuth (Bi) thin films in a vacuum on glass substrate and on Si wafer to produce n-Bi2O3/p-Si heterojunction. The effect of thickness on the structural, electrical, surface and optical properties of Bi2O3 thin films was studied. XRD analysis reveals that all the as deposited Bi2O3 films show polycrystalline tetragonal structure, with preferential orientation in the (201) direction, without any change in structure due to increase of film thickness. AFM and SEM images are used to investigate the influences of film thickness on surface properties. The optical measur

... Show More
Preview PDF