Background: It has been well known that the success of mandibular implant- retained overdenture heavily depends on initial stability, retention and long term osseointegration this is might be due to optimal stresses distribution in surrounding bones. Types of mandibular implant- retained overdenture anchorage system and number of dental implants play an important role in stresses distribution at the implant-bone interface. It is necessary to keep the stresses below the physiologic tolerance level of the bone .since. And it is difficult to measure these stresses around bone in vivo. In the present study, finite element analysis used to study the stresses distribution around dental implant supporting Mandible implant retained overdenture Materials and methods: Eight models were constructed including four designs of anchorage system (ball-cup, ball-O Ring, bar without distal extension and bar with distal extension).The first group of models were supported by four dental implant and second group of models were supported by two dental implant only. Models constructed from the data obtained directly from patient The contour of bone was obtained from C.T scan image of patient, then data transferred to ANSYS program for modeling then load applied and solve the equation by the program, Specified nodes were selected at the rings of crestal bone (cortical bone) and cortical cancellous interface around each dental implant and fixed for all models to monitor the stress change in that regions of different design of MIR-OD.. After load application, Specified nodes were selected at the rings of crestal bone (cortical bone) and cortical cancellous interface around each dental implant and fixed for all models to monitor the stress change in that regions of different design of MIR-OD . Results: In the present study the stress distribution and maximum stresses value around dental implant had a relationship to the number of dental implant. , The result appeared that the maximum stresses and means of stresses value was lower in the first group of models (which was supported through the use four dental implant) than the second group of models (which was supported through the use of two dental implant only). For the first group of models the maximum stresses value around mesial implant was11.67, 10.51, 10.98 and 10.72 Mpa, while the maximum stresses around distal implant was 21.33, 18.51, 18.86, and17.56 Mpa for models 1,2,3 and 4respectively ,and the stresses around implant supporting second group of models was 22.52, 22.16, 20.51 and 19.60 Mpa for models 5,6,7and8 respectively .Statistical analyses of means value appeared that there was statistically significant difference in stresses means value around implant of the second group with that’s values around mesial and distal implant supporting first group of model . Regarding the result of both ball and bar system, it has been demonstrated that stress was greater with ball attachment and MIR-OD supported by the use of four dental implants and anchored by bar attachments with distal extension gives the minimum values of stresses than the rest models. Also the results show that higher stresses value was appeared at the cortical bone ring surrounding dental implant especially the distal implant nearest to the free end extension area. Also it was appeared that the best model was Mandible implant- retained overdenture that’s anchored by bar with distal extension and support by four dental implant. Conclusions: Bar-clips with distal extension mode of attachment considered the best type in producing the least stresses around dental implant regardless number of dental implant used.
Analysis system of sports players is very important for individuals in weightlifting. Assessment of player and strength is important for the performance of weightlifting. This paper proposes an analytical method for weightlifters with check-by-frame video. This analysis system can compute the major steps of seven positions in both snatch and clean and jerk methods in frame-video weightlifting monitoring of movements. Each user can compute the major steps of the seven positions of Hu moments among two frames in the video during training, and the Euclidian distance can be computed for the Hu moment values and lifting moment values in the snatch and clean and jerk methods during training. The outcome of the proposed system shows on efficien
... Show MoreA numerical study of the double-diffusive laminar natural convection in a right triangular solar collector has been investigated in present work. The base (absorber) and glass cover of the collector are isothermal and isoconcentration surfaces, while the vertical wall is considered adiabatic and impermeable. Both aiding and opposing buoyancy forces have been studied. Governing equations in vorticity-stream function form are discretized via finite-difference method and are solved numerically by iterative successive under relaxation (SUR) technique. Computer code for MATLAB software has been developed and written to solve mathematical model. Results in the form of streamlines, isotherms, isoconcentration, average Nusselt, and average Sherw
... Show MoreBackground: The study of human leukocytes (HLA) alleles, and haplotype frequencies within populations provide an important source of information for anthropological investigation, organ and hematopoietic stem cell transplantation as well as disease association, certain diseases showed association with specific alleles specially those of known or suspected hereditary origin or immunological basis, whether simple renal cyst is congenital or acquired is still unclear and need to be investigated.Objectives: To study the genetic aspect of simple renal cysts by detecting the gene frequency and the haplotype of HLA class I of patients with simple renal cysts, and to find the presence of these cysts in other family members.Method: Thirty patient
... Show MoreFlat-plate collector considers most common types of collectors, for ease of manufacturing and low price compared with other collectors. The main aim of the present work is to increase the efficiency of the collector, which can be achieved by improving the heat transfer and minimize heat loss experimentally. Five types of solar air collectors have been tested, which conventional channel with a smooth absorber plate (model I), dual channel with a smooth absorber plate (model II), dual channel with perforating “V” corrugated absorber plate (model III), dual channel with internal attached wire mesh (model Ⅳ), and dual channel with absorber sheet of transparent honeycomb, (model Ⅴ). The dual channel collector used for
... Show MoreThe current research aims to analyze the chemistry books for the preparatory stage according to life skills for the academic year (2019-2020) and to know the life skills contained in the chemistry books for the preparatory stage through the following two questions:1-What life skills should be available in the content of chemistry books prescribed for middle school students approved by the Ministry of Education, General Directorate of Curricula in the academic year(2019-2020). 2-What is the percentage of life skills included in the content of chemistry textbooks prescribed for middle school students approved by the Ministry of Education, General Directorate of Curricula in the academic year (2019-2020). To achieve the objectives of the resea
... Show MoreThe present study was performed to detect the molecular and the phylogenetic identification of species that belonging to the genus of Moniezia Blanchard, 1891 which affected intestines of sheep in Al-Diwaniyah city, Iraq; fifty intestine samples were sought for the infestation of Moniezia spp. from the city slaughterhouse from 1 October to 30 November 2017, this tapeworm was found to infest the intestines of 13 sheep.
For morphological identify the genus of this tapeworm, eggs from one gravid proglottid of the thirteen worms were examined, polymerase chain reaction (PCR) and the PCR-product-based sequencing were applied on 4 Moniezia tapeworms targeti
... Show MoreObjective This study aimed to compare the biomechanics of three-point shooting between elite Iraqi basketball players and international players, in order to identify key biomechanical differences that may impact shooting performance. Methods A total of 80 male basketball players participated in the study (40 elite Iraqi players and 40 international elite players). Kinematic data were collected using advanced motion analysis systems, force plates, and high-speed video analysis. The measured variables included joint angles, angular velocity, release speed, ball release angle, and ground reaction forces during three-point shooting. Each player performed 20 consecutive shots under controlled conditions. Group comparisons were conducted using st
... Show MoreA cumulative review with a systematic approach aimed to provide a comparison of studies’ investigating the possible impact of the active form of vitamin D3, calcitriol (CTL), on the tooth movement caused by orthodontic forces (OTM) by evaluating the quality of evidence, based on collating current data from animal model studies, in vivo cell culture studies, and human clinical trials. Methods: A strict systematic review protocol was applied following the application of the International Prospective Register of Systematic Reviews (PROSPERO). A structured search strategy, including main keywords, was defined during detailed search with the application of electronic database systems: Medline/Pubmed, EMBASE, Scopus, Web of Science, and
... Show MoreComparative Analysis of Economic Policy Stability between Monarchical and Republican Systems: A Theoretical Fundamental Research