Background: Endodontically treated teeth have low resistance to fracture against occlusal forces. The strengthening effect of bonded esthetic onlay restoration on weakened tooth has been reported. This study aimed to assess the fracture resistance of endodontically treated premolars restored with composite with and without cuspal coverage by using direct and indirect techniques. Indirect technique done by CAD/CAM system (computer aided design –computer aided manufacturer) and laboratory processing. Material and methods: Forty human extracted maxillary premolars of approximately comparable sizes were divided into four groups: Group (A): Ten endodontically treated teeth directly filled with Filtek Z250xt without cuspal coverage. Group (B): Ten endodontically treated teeth prepared with onlay cavities and restored directly with Filtek Z250 XT. Group(C): Ten endodontically treated teeth prepared with onlay cavities and restored indirectly with Filtek Z250 XT. Group (D): Ten endodontically treated teeth prepared with onlay cavities and restored indirectly with Paradigm MZ100 CAD/CAM blocks. Fracture strength of the samples was measured by using universal testing machine (an axial compression test). Data were analyzed statistically by one way ANOVA test and least significant difference test, Results showed that Group A has the lowest fracture resistance value than all experimental Groups and the difference are highly significant. While Group B has a high significant fracture resistant value than the indirectly restored groups. Group C and Group D showed an approximate fracture resistant result (1.13KN and 1.07KN respectively) and the difference is statistically not significant. Conclusion All CAD/CAM composite onlay, indirect Filtek z250 XT and direct cuspal coverage survived maximum biting force for posterior single tooth, so these types of onlays provide good reinforcement in an extensive MOD cavities in premolars The mode of fracture for Group D was 90% restorable which is higher than group C (80%) restorable and group B (30%) restorable type of fracture.
The work concerned with studying the effect of (SiO2) addition as a
filler on the adhesive properties of (PVA). Samples were prepared as
sheets by using casting method. The mechanical properties showed
that increase in tensile strength from (34MPa) to (68MPa) when
(SiO2) added to (PVA). The adhesive strength showed that joint
properties depend upon specific adhesive characteristic of material
(PVA) and (SiO2\PVA)composites at different concentrations (1.5%,
2.5%, 3.5%, 4.5wt%), the cohesive strength of the adhesive material,
the joint design, and adherent type (Sponge Rubber(SR), Natural
leather (NL), Vulcanized Rubber(VR), and Cartoon). The results
proved the tensile strength increased with (SiO2) ratio, so
Evaluation of the Antibacterial Efficacy of Electrolyzed Oxidizing Water as an Irrigant against Enterococcus faecalis (An In vitro Study), Noor A Khait*, Muna Saleem Kalaf
In this research is to study the influence of the aging heat treatment on the pitting corrosion resistance of martensitic stainless steel (MSS), where a number of specimens from martensitic stainless steel were subjected to solution treatment at 1100 oC for one hour followed by water quenching then aging in the temperatures range (500-750) oC for different holding times (1,5,10,15&20) hr. Accelerated chemical corrosion test and immersion chemical corrosion test were performed on samples after heat treatment. The results of the research showed that the pitting corrosion resistance is significantly affected by the aging temperature. Where found that the aging samples at a temperature of 500 °C have the highest ra
... Show MoreThis research focuses on improvement of the corrosion behaviour of commercial pure titanium (Ti) grade II when exposed to Hank’s solution through different surface treatments. The disc shape of titanium samples were constructed to be divided according to their surface treatment. The first experimental group the Ti sample was exposed to computer numerical control (CNC) fiber laser machine. Whereas, the other experimental group the Ti sample was only coated with Polyetherketon keton (PEKK) by using carbon dioxide (CO2) laser technique while the last experimental group the Ti sample was treated with CNC fiber laser followed by PEKK coating by using CO2 laser technique. All were compared with the untreated control group. The electrochemical a
... Show MoreBackground: This in vitro study compares a novel calcium-phosphate etchant paste to conventional 37% phosphoric acid gel for bonding metal and ceramic brackets by evaluating the shear bond strength, remnant adhesive and enamel damage following water storage, acid challenge and fatigue loading. Material and Methods: Metal and ceramic brackets were bonded to 240 extracted human premolars using two enamel conditioning protocols: conventional 37% phosphoric acid (PA) gel (control), and an acidic calcium-phosphate (CaP) paste. The CaP paste was prepared from β-tricalcium phosphate and monocalcium phosphate monohydrate powders mixed with 37% phosphoric acid solution, and the resulting phase was confirmed using FTIR. The bonded premolars were exp
... Show MoreObjective: to evaluate the results of (Modification of Russe method) in treatment of nonunion fracture scaphoid bone by bone graft with external splintage (plaster of paris cast (pop ). Methods:Prospective study done on 26 patients (24 male, 2 female), age range between 25-42 years (mean age 34 years), fracture site at middle 1/3 with minimal displacements with no carpal bone or radial bone injury, technique of Matte- Russe method (explore the bone through volar approach using bone graft from iliac crest (cortico-cancellous peg plus cancellus bone) with thumb spica for 90 days with period of follow up 12-18 months. Results: out of 26 patients treated by this method , 23 patients (88.5%) union was achieved radiologically by the end of 3rd mo
... Show MoreObjective: to evaluate the results of (Modification of Russe method) in treatment of nonunion fracture scaphoid bone by bone graft with external splintage (plaster of paris cast (pop ).
Methods:Prospective study done on 26 patients (24 male, 2 female), age range between 25-42 years (mean age 34 years), fracture site at middle 1/3 with minimal displacements with no carpal bone or radial bone injury, technique of Matte- Russe method (explore the bone through volar approach using bone graft from iliac crest (cortico-cancellous peg plus cancellus bone) with thumb spica for 90 days with period of follow up 12-18 months.
Results: out of 26 patients treated by this method , 23 patients (88.5%) union was achieved radiologically by the end
Objectives: To assess the performance of a novel resin-modified glass-ionomer cement (pRMGIC) bonded to various tooth tissues after two-time intervals. Methods: 192 sound human molars were randomly assigned to 3 groups (n = 64): sound enamel, demineralised enamel, sound dentine. Sixty-four teeth with natural carious lesions including caries-affected dentine (CAD) were selected. All substrates were prepared, conditioned and restored with pRMGIC (30% ethylene glycol methacrylate phosphate (EGMP, experimental), Fuji II LC (control), Fuji IX, and Filtek™ Supreme with Scotchbond ™ Universal Adhesive. Shear bond strength (SBS) was determined after 24 h and three months storage in SBF at 37C. The debonded surfaces were examined using stereomi
... Show MoreBackground: The aim of this study was to measure the radiopacity (RO) of modified microhybrid composite resins by adding 2 types of nanofillers (Zinc Oxide and Calcium Carbonate) in two concentrations 3% and 5% and comparing them to unmodified microhybrid composite resins and to nanofilled composite resin. Materials and Methods: Two types of composite resin were used (Microhybrid composite MH Quadrent anterior shine and Nanofilled composite resin Filtek Z350 XT), for each tested group five disk-shaped specimens (1-mm-thick and 15 mm diameter) were fabricated. The material samples were radiographed together with the aluminum step wedge. The density of the specimens was determined with a transmission densitometer and was expressed in term of
... Show More