Preferred Language
Articles
/
jbcd-3515
Effects of fixed orthodontic appliance with antihypertensive drugs on the body weight of experimental rats
...Show More Authors

Background: This study aims to investigate the effect of fixed orthodontic appliances and/or antihypertensive drugs on the weight of experimental rats. Materials and Methods: Thir-ty-six male Wistar albino rats were subjected to a split-mouth design study, in which an orthodontic appliance was inserted in one side to move the first molar mesially for 2 weeks while the other side acted as a control to tooth movement. The rats were allocated into three groups: group A (n = 12), without any pharmacological treatment; group B (n = 12), subcu-taneous injection of bisoprolol fumarate (5 mg/kg) daily; and group C (n = 12), subcutaneous injection of valsartan (10 mg/kg) daily. A fixed orthodontic appliance with a closing coil spring delivering 50 gm of force was used to move the first molar mesially while the incisors served as an anchor unit. The weight of the rats was measured on days 1 (the day of appli-ance insertion), 7, and 14. Results: No significant (P > 0.05) difference in the body weight of rats was found among the three groups at each time point; however, significant (P < 0.05) weight loss was noted after the first and second week of the experiment in all study groups. Conclusion: The body weight loss of rats following the insertion of a fixed orthodontic ap-pliance could be related to the effects of the appliance rather than the administered antihy-pertensive drugs.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Mar 01 2023
Journal Name
Journal Of Engineering
Experimental Study on the Behavior of Square-Skirted Foundation Rested on Gypseous soil Under Inclined Load
...Show More Authors

This work investigates experimentally the effect of using a skirt with a square foundation of 100 mm width resting on dry gypseous soil (i.e., loose soil with 33% relative density), and subjected to an inclined load. Previous works did not study the use square skirted foundation rested on gypseous soil and subjected to inclined load. The investigated soil was brought from Tikrit city with 59% gypsum content. Standard physical and chemical tests on selected soil were carried out. Model laboratory tests were carried out to determine the effect of using a skirt with a square foundation on the load-settlement behavior of gypseous soil and subjected to inclined load with various Skirt depth (Ds) to foundation width (B) ratio

... Show More
View Publication Preview PDF
Scopus (17)
Crossref (8)
Scopus Crossref
Publication Date
Thu Jan 10 2019
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Numerical and Experimental Study of Winglet Effect with Different Cant Angles
...Show More Authors

The present work aims to investigate the aerodynamic characteristics of the winglet cant angle of Boeing 737-800 wing numerically and experimentally. The wing contain two swept angles 38.3o and 29.13o respectively, taper ratio 0.15 and aspect ratio 8.04. The wing involves three types of airfoils sections. Four cant angles for blended winglet have been considered (0o, 34o, 60o, 83.3o). The winglet has been analyzed to find the best cant angle for the wing without and with winglet. These models have been tested theoretically at Reynolds number of 2.06 x106 in order to study the winglet aerodynamic characteristics which consist of coefficient of Drag, coefficient of lift and Lift to drag ratio, pitching moment coefficient and bending moment co

... Show More
Publication Date
Tue Oct 01 2019
Journal Name
Journal Of Engineering
Generation and Experimental Stress Analysis of Elliptical Gears with Combined Teeth
...Show More Authors

In this study, generation of elliptical gears with different teeth profiles of crowned involute, double circular arc (DCA), and combined (crowned involute with DCA) has been developed. The resulting mathematical equations have been computerized and feed to CNC end mill machine to manufacture elliptical gear models with different profiles. These models are investigated in plane polariscope to show the resulting stresses under certain load. Comparison of photo-elastic stress results shows that combined elliptical gears with DCA side as a loaded side have a minimum resulting contact stress with a reduction percentage of 40% compare with contact stresses in counterpart elliptical gear of involute profile (which is commonly u

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Aug 16 2016
Journal Name
International Journal Of Computer Applications
Experimental Study of CLARK-Y Smoothed Inverted Wing with Ground Effect
...Show More Authors

View Publication
Crossref (2)
Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of Engineering
Theoretical and Experimental Stress Analysis of Cam With Simple Harmonic Motion
...Show More Authors

Cams are considered as one of the most important mechanical components that depends the contact action to do its job and suffer a lot of with drawbacks to be predicted and overcame in the design process. this work aims to investigate the induced cam contact and the maximum shear stress energy or (von misses) stresses during the course of action analytically using Hertz contact stress equation and the principal stress formulations to find the maximum stress value and its position beneath the contacting surfaces. The experimental investigation adopted two dimensions photoelastic technique to analyze cam stresses under a plane polarized light. The problem has been numerically simulated using Ansys software version 15 as FE

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 01 2017
Journal Name
International Journal Of Science And Nature
FREQUENCY OF LOW BIRTH WEIGHT AMONG NEONATES ADMITTEDTO THE NEONATAL INTENSIVE CARE UNIT
...Show More Authors

Publication Date
Mon Aug 03 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Acidity Level on Ions Released and Corrosion of Metal Orthodontic Appliances at Different Time Intervals (An In vitro Study)
...Show More Authors

ABSTRACT Background: This study measured the effects of three parameters pH value, length of immersion and type of archwire on metal ions released from orthodontic appliances. Materials and Methods: Ninety maxillary halves simulated fixed orthodontic appliances that were immersed in artificial saliva of different pH values (6.75, 5 and 3.5) during 28 day period. Three types of archwires were used: stainless steel, nickel titanium and thermal activated nickel titanium. The quantity of nickel and chromium ions was determined with the use of atomic force spectrophotometer while iron ions by spectrophotometer. Each orthodontic set was weighted two times, before the ligation and immersion in the artificial saliva and after 28 days at the end of

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Validity of Digital and Rapid Prototyped Orthodontic Study Models
...Show More Authors

Background: The integration of modern computer-aided design and manufacturing technologies in diagnosis, treatment planning, and appliance construction is changing the way in which orthodontic treatment is provided to patients. The aim of this study is to assess the validity of digital and rapid prototyped orthodontic study models as compared to their original stone models. Materials and methods: The sample of the study consisted of 30 study models with well-aligned, Angle Class I malocclusion. The models were digitized with desktop scanner to create digital models. Digital files were then converted to plastic physical casts using prototyping machine, which utilizes the fused deposition modeling technology. Polylactic acid polymer was chose

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Dec 15 2022
Journal Name
Journal Of Baghdad College Of Dentistry
Force degradation of orthodontic elastomeric chains: A literature review
...Show More Authors

Background: Elastomeric chains are used to generate force in many orthodontic procedures, but this force decays over time, which could affect tooth movement. This study aimed to study the force degradation of elastomeric chains. Data and Sources: An electronic search on Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, LILACS, and PubMed was made, only articles written in English were included, up to January 2022.Study selection: Fifty original articles, systematic reviews, and RCTs were selected. Conclusion: Tooth movement, salivary enzymes, alcohol-containing mouthwash, whitening mouthwash, and alkaline and strong acidic (pH <5.4) solutions all have a significant impact on elastomeric chain force degradation. T

... Show More
Scopus (4)
Crossref (4)
Scopus Crossref
Publication Date
Wed Oct 01 2025
Journal Name
Assiut Veterinary Medical Journal
EFFECT OF LONG-TERM ADMINISTRATION OF MONOSODIUM GLUTAMATE ON THE HISTOLOGICAL STRUCTURE OF THE THYROID GLAND IN ADULT MALE ALBINO RATS
...Show More Authors

View Publication
Scopus Crossref