Background: The microhardness of a composite resin is a vital parameter that is used to determine its clinical behavior. Measuring the microhardness of a composite resin has been used as an indirect method to assess its degree of conversion and extent of polymerization. The purpose of this in vitro study was to evaluate the effect of three curing distances (0, 2, and 4 mm) on the microhardness of the top and bottom surfaces of three types of flowable bulk-fill composite resins (smart dentin replacement, Opus bulk fill flow, and Tetric N). Material and method: Sixty-three specimens from the three types of composite resins (n=21) were fabricated using Teflon mold with a 4mm depth and a 5 mm internal diameter and cured for 20 seconds. For each material, three subgroups were fabricated according to the position of the light curing tip from the top surface; at 0, 2, and 4 mm distances. Microhardness was measured using the Vickers test with a 50-g load for 15 seconds for the top and bottom surfaces of all the samples. Results: The microhardness values were decreased in the following order; 0mm > 2mm > 4mm curing tip distance, for both sides and Tetric N had the highest microhardness values. Significant differences in microhardness were recorded between the top and bottom surfaces for all the specimens (p<0.05). Conclusion: Increasing the distances between the tip of the light cure and the surface of flowable bulk-fill resins can significantly decrease the microhardness of the bottom surfaces compared to the top surfaces.
The experiment was carried out in the green house of botanical garden belong to Department of Biology/College of Education for Pure Science Ibn AL-Haitham, University of Baghdad for growing season 2017-2018 to evaluate effect of lead stress with concentrations (0, 50, 100, 150) mg.L -1 and Selenium concentrations (0, 15, 30) mg.L-1 on growth of dill plant using pots. The experiment was designed according to completely randomized design (CRD) with three replications. Result indicated that dill plants subjected to lead stress with height concentrations caused decrease in plant parameters (plant height, no. of branches. plant-1, root length, shoot dry weight, the content of nitrogen, phosphorus and potassium, protein concentration, no. of umbe
... Show MoreIn this research TiO2 nano-powder was prepared by a spray pyrolysis technique and then adds to the TiO2 powder with particle size (0.523 μm) in ratio (0, 5, 10, 15 at %) atomic percentage, and then deposition of the mixture on the stainless steel 316 L substrate in order to use in medical and industrial applications.
Structure properties including x-ray diffraction (XRD) and scanning electron microscope (SEM0, also some of mechanical properties and the effect of thermal annealing in different temperature have been studied. The results show that the particle size of a prepared nano-powder was 50 up to 75 nm from SEM, and the crystal structure of the powders (original and nano powder) was rutile with tetragonal cell. An improvement in
The study aimed to identify the effect of Total Quality Management on enhancing competitiveness through the opinions of employees of the front- rows of customer service in local Palestinian banks, the researcher adopted an analytical descriptive method through developing a special questionnaire to accomplish the study’s objectives and answer its questions. The study involved all the Palestinian local banks, with their scattered branches in West Bank. The study sample consisted of 3470 executive employees for banking services out of 4753 employees, in the rate of 73%, and the study sample reached (485) employees who were randomly selected working in the front -rows to provide services in the local Palestinian banks during the ye
... Show MoreAbstract: In this paper, a U-shaped probe with a curvature diameter of half a centimeter was implemented using plastic optical fibers. A layer of the outer shell of the fibers was removed by polishing to a D-section. The sensor was tested by immersing it in a sodium chloride solution with variable refractive index depending on solution concentrations ranging from 1.333 to 1.363. In this design, the sensor experienced a decrease in its intensity as the concentration of the solution increased. The next step The sensor was coated with a thin layer of gold with a thickness of 20 nm, and the sensor was tested with the same solutions which resulted in a shift in wavelengths where the shift in wavelength was 5.37 nm and sensiti
... Show MoreABSRTACT Background: Soft liner material is become important in dental prosthetic treatment. They are applied to the surface of the dentures to achieve more equal force distribution , reduce localized pressure and improve denture retention by engaging undercut . So the aim of the study is to evaluate the effect of different surface treatment by air-abrasion AL2O3 and laser treatment with CO2 laser on improving the shear bond strength of the denture liner to acrylic denture base material . Materials and methods: the 30 specimens of heat cured acrylic denture base material (high Impact acrylic )and heat cured soft liner (Vertex ,Nether Lands )were prepared for this study .They were designed and divided according to type of the s
... Show MoreTo evaluate the Interaction of Mn(II), Fe(II), Co(II), Ni(II),Cu(II), Zn(II) And Cd(II) Mixed- Ligand Complexes of cephalexin mono hydrate (antibiotics) And Furan-2-Carboxylic Acid To The Different DNA Sources. All the metal complexes were observed to cleave the DNA. A difference in the bands of complexes .The cleavage efficiency of the complexes compared with that of the control is due to their efficient DNA-binding ability and the other factors like solubility and bond length between the metal and ligand may also increase the DNA-binding ability. The ligands (Cephalexin mono hydrate (antibiotics) and Furan-2- Carboxylic acid and there newly synthesized metal complexes shows good antimicrobial activities and Binding DNA , thus, can be used
... Show MoreBuckling and free vibration analysis of laminated rectangular plates with uniform and non uniform distributed in-plane compressive loadings along two opposite edges is performed using the Ritz method. Classical laminated plate theory is adopted. The static component of the applied in- plane loading are assumed to vary according to uniform, parabolic or linear distributions. Initially, the plate membrane problem is solved using the Ritz method; subsequently, using Hamilton’s variational principle, linear homogeneous algebraic equations in terms of unknown are generated, the set of linear algebraic equations can be solved as an Eigen-value problem. Buckling loads for laminated plates with different combinations of bounda
... Show MoreThis study deals with the estimation of critical load of unidirectional polymer matrix composite plates by using experimental and finite element techniques at different fiber angles and fiber volume fraction of the composite plate.
Buckling analysis illustrated that the critical load decreases in nonlinear relationship with the increase of the fiber angle and that it increases with the increase of the fiber volume fraction.
The results show that the maximum value of the critical load is (629.54 N/m) at (q = 0°) and (Vf = 40 %) for the finite element method, while the minimum val
... Show More