Background: Color stability of glass ionomers (GIs) could be affected by many factors such as pH and consumption of liquid medications like antibiotics. Most common antibiotics used during childhood are amoxicillin suspension (AM.S) and azithromycin suspension (AZ.S) which have acidic and basic pH respectively. Aim: to evaluate and compare the effect of AM.S and AZ.S on color stability of nano resin-modified GI. Methods: Thirty disc of nano resin-modified glass ionomer (2mm height x 4mm diameter) were divided into three groups (n=10 for each) and independently exposed to AM.S, AZ.S, and artificial saliva (A.S.). Color stability was evaluated in triplicate by VITA Easyshade® before and after three immersion protocols, repeated over a three-week duration with two-days intervals. In each protocol, samples were exposed for two minutes, three times daily for AM.S, once daily for AZ.S, and A.S. full day. GI discs rinsed off after each immersion and kept in artificial saliva until next immersion period. Results: One way ANOVA test and Post-hoc analysis of the changes in color space compartments of nano-resin modified GI samples demonstrated just a significant change (p˂0.05) in yellow-blue axis (Δb*) value after immersion in AM.S in comparison with A.S. Total Color change values (ΔE) of nano resin-modified glass ionomer samples also illustrated a significant effect (p˂0.05) between AM.S and A.S. only. The highest (ΔE) value was recorded for samples immersed in AM.S (ΔE =12.5) followed by AZ.S (ΔE=6.5) while the lowest was recorded for A.S. (ΔE=1.1). Conclusion: AM.S (the acidic medication) exhibited a higher staining effect to nano-resin modified GI samples when compared with AZ.S (the basic medication). Several factors such as low pH, more exposure time and coloring material of the immersion media added critical roles in coloring instability.
The proposed work is an attempt to investigate the stability of the nonlinear system by using a whale optimization algorithm as of one of the meta-heuristic optimization methods, and this investigation was conducted on a single inverted pendulum as a study model. The evaluation measures which were used in this article values of gain and sliding surface of the conventional sliding mode controller to illustrate the extent of the system`s stability. Furthermore, control action, the relationship between error and its derivative, desired, and actual position in addition to sliding response graphically showed the feasibility of the proposed solution. The attained results illustrated considerable improvement in the settling time and minimizing the
... Show MoreBackground: Glass ionomer restorations are widely employed in the field of pediatric dentistry. There is a constant demand for a durable restoration that remains functional until exfoliation. This study aimed to measure and compare the effect of a novel coating material (EQUIA Forte Coat) on the microleakage of glass hybrid restoration (EQUIA Forte HT) in primary teeth. Material and method: Thirty cavitated (class-II) primary molars were allocated randomly into two groups based on the coat application; uncoated (control) and coated group (experimental). Cavities were prepared by the use of a ceramic bur (CeraBur) and restored with EQUIA Forte HT with or without applying a protective coat (EQUIA Forte Coat). Samples went through the therm
... Show MoreBackground: Glass ionomer restorations are widely employed in the field of pediatric dentistry. There is a constant demand for a durable restoration that remains functional until exfoliation. This study aimed to measure and compare the effect of a novel coating material (EQUIA Forte Coat) on the microleakage of glass hybrid restoration (EQUIA Forte HT) in primary teeth. Material and method: Thirty cavitated (class-II) primary molars were allocated randomly into two groups based on the coat application; uncoated (control) and coated group (experimental). Cavities were prepared by the use of a ceramic bur (CeraBur) and restored with EQUIA Forte HT with or without applying a protective coat (EQUIA Forte Coat). Samples went through the
... Show MoreThe wear behavior of alumina particulate reinforced A332 aluminium alloy composites produced by a stir casting process technique were investigated. A pin-on-disc type apparatus was employed for determining the sliding wear rate in composite samples at different grain size (1 µm, 12µm, 50 nm) and different weight percentage (0.05-0.1-0.5-1) wt% of alumina respectively. Mechanical properties characterization which strongly depends on microstructure properties of reinforcement revealed that the presence of ( nano , micro) alumina particulates lead to simultaneous increase in hardness, ultimate tensile stress (UTS), wear resistances. The results revealed that UTS, Hardness, Wear resistances increases with the increase in the percentage of
... Show MoreA new modified differential evolution algorithm DE-BEA, is proposed to improve the reliability of the standard DE/current-to-rand/1/bin by implementing a new mutation scheme inspired by the bacterial evolutionary algorithm (BEA). The crossover and the selection schemes of the DE method are also modified to fit the new DE-BEA mechanism. The new scheme diversifies the population by applying to all the individuals a segment based scheme that generates multiple copies (clones) from each individual one-by-one and applies the BEA segment-wise mechanism. These new steps are embedded in the DE/current-to-rand/bin scheme. The performance of the new algorithm has been compared with several DE variants over eighteen benchmark functions including sever
... Show MoreThis study concerns the removal of a trihydrate antibiotic (Amoxicillin) from synthetically contaminated water by adsorption on modified bentonite. The bentonite was modified using hexadecyl trimethyl ammonium bromide (HTAB), which turned it from a hydrophilic to a hydrophobic material. The effects of different parameters were studied in batch experiments. These parameters were contact time, solution pH, agitation speed, initial concentration (C0) of the contaminant, and adsorbent dosage. Maximum removal of amoxicillin (93 %) was achieved at contact time = 240 min, pH = 10, agitation speed = 200 rpm, initial concentration = 30 ppm, and adsorbent dosage = 3 g bentonite per 1L of pollutant solution. The characterization of the adsorbent, modi
... Show MoreThe approval of the federal general budget in Iraq is one of the most important competencies of the legislative authority , Being one of the important financial and monetary policy instruments on which the state depends for its economic growth , Hence, the obstruction of the approval of the federal budget due to sectarian quotas, the absence of national interest, and the emergence of bargaining processes between political parties belonging to the regions and sectarianism , As well as the absence of economic plans and programs as a result of non-cognition and understanding of the nature of its supposed political system applied in Iraq and the absence of specialists would le
... Show MoreReceipt date: 2/2/2021 accepted date: 4/6/2021 Publication date: 12/31/2021
This work is licensed under a Creative Commons Attribution 4.0 International License.
The approval of the federal general budget in Iraq is one of the most important competencies of the legislative authority , Being one of the important financial and monetary policy instruments on which the state depends for its economic growth , Hence, the obstruction of the approval of the federal b
... Show MoreA Raman spectroscopy method was optimised to examine the chemical changes of aspirin tablets after interaction with helium temperatures. Several aspirin tablets were exposed to plasma-assisted desorption ionisation flame for different times (10, 30, 50, 60, 180 and 300s) and then analysed by Raman spectroscopy using optimal conditions. The changes in chemistry between exposed and fresh (without exposure to plasma) tablets were compared. The vibrational peaks of the aspirin molecule in the Raman spectrum were identified by checking the peak position. The results showed clear spectra with increases in intensity of vibrational peaks until 30s, whereas no spectra were measured for the exposed tablets to plasma flame after 50s. It can, the
... Show More