Preferred Language
Articles
/
jbcd-3455
Reliability of the multipeg™ transducer in measuring dental implant stability by using a resonance frequency analysis device (Osstell®): An observational clinical study
...Show More Authors

Background: Measuring implant stability is an important issue in predicting treatment success. Dental implant stability is usually measured through resonance frequency analysis (RFA). Osstell® RFA devices can be used with transducers (Smartpeg™) that correspond to the implants used as well as with transducers designed for application with Penguin® RFA devices (Multipeg™). Aims: This study aims to assess the reliability of a MultiPeg™ transducer with an Osstell® device in measuring dental implant stability. Materials and Methods: Sixteen healthy participants who required dental implant treatment were enrolled in this study. Implant stability was measured by using an Osstell® device with two transducers, namely, Smartpeg™ and Multipeg™. Insertion torque was also measured and recorded as >50 and ≤50 N·cm. Unpaired t-test and Mann–Whitney U test were conducted to assess the relationships of the implant stability values obtained by the two transducers with insertion torque, whereas Pearson and Spearman's correlations were utilized to investigate correlations between the two transducers. Interclass correlation coefficients were applied to assess the reliability between the two transducers. Results: Implant stability measurements (primary and secondary) showed strong positive correlations between Smartpeg™ and Multipeg™. The reliability values between both transducers in primary and secondary implant stability measurements were 0.922 and 0.981, respectively. The use of both transducers revealed higher implant stability measurements for implants inserted with insertion torque > 50 N·cm than those inserted with insertion torque ≤ 50 N·cm. Conclusions: This study demonstrated that the Multipeg™ transducer is reliable in measuring the stability of dental implants using an Osstell® device.   

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jun 20 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The relationship among bite force with facial dimensions and dental arches widths in a sample of Iraqi adults with Class I skeletal and dental relations
...Show More Authors

Background: This study aimed to determine whether there is a relationship among the bite force with facial dimensions and dental arches in a sample of Iraqi adults with Class I skeletal and dental relations. Materials and methods: Forty dental students (20 males and 20 females) were selected under certain criteria. For those individuals, dental impressions, frontal facial photographs and maximum bite force at molar and incisor regions were taken. The dental arches widths and facial dimensions were measured using the AutoCAD program 2007, while the bite force was determined using special device. Descriptive statistics for the measured variables were performed and gender difference was determined using independent sample t-test, while the rel

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 01 2021
Journal Name
International Medical Journal
Effect of Accelerated Canine Retraction by Vitamin D3 Local Administration on Apical Root Resorption, Alveolar Bone Integrity, and Chair-side Time: A Prospective Clinical Study.
...Show More Authors

Objectives: To evaluate the effect of vitamin D3 local injections on apical root resorption, alveolar bone integrity, and chair-side time following three and six months of canine retraction. Subjects and Methods: Seventeen adult patients (18-35 years old) of class I and II malocclusions were recruited, who required bilateral maxillary 1st premolars extraction before starting maxillary canines retraction. The experimental side received 25 pg dose of vitamin D3 injected locally into the distal periodontal sulcus of the canine (before force application) every three weeks, while the control side received retraction force only. Periapical radiographic evaluation was conducted after 3 and 6 months of the start of canines' retraction. Results: At

... Show More
Preview PDF
Publication Date
Fri Jun 02 2023
Journal Name
Bandaoti Guangdian/semiconductor Optoelectronics
NMUSING AN INNOVATIVE DEVICE TO IMPROVE THE EFFICIENCY OF THE ANTERIOR QUADRICEPS MUSCLE OF THE INJURED KNEE JOINT AFTER SURGICAL INTERVENTION OF THE ANTERIOR CRUCIATE LIGAMENT IN ADVANCED SOCCER PLAYERS
...Show More Authors

This study aimed to manufacture an innovative device that enables the player to walk after the operation and improves the functional efficiency through the improvement in the range of motion as well as the improvement in the size of the muscles working on the knee joint. The research, the study population consisted of players with severing the anterior cruciate ligament of the advanced soccer players, and the number of the research sample was (5) injured for the control sample and (5) for the experimental sample in Abu Ghraib Hospital and some rehabilitation centers for a period of six months, and the pre-tests were conducted after two weeks of The cruciate ligament surgery was performed, and the innovative device was used for the e

... Show More
Preview PDF
Publication Date
Fri Sep 15 2023
Journal Name
Technology And Health Care
Clinical management and infection control protocols during the COVID-19 pandemic: An online survey
...Show More Authors

BACKGROUND: SARS-CoV-2 (COVID-19) is considered a highly infectious and life threatening disease. OBJECTIVE: The present paper aims to evaluate various aspects of preventive measures and clinical management of the scheduled visits for orthodontic patients to the dental clinics during the outbreak of COVID-19, and to assess how orthodontists dealt with this challenge. METHODS: Orthodontists in private and public clinics were invited to fill a questionnaire that addressed infection control protocols and concerns about clinical management of patients in the clinics during the pandemic. Frequncies and percentages of the responses were obtained and compared using Chi-square tests. RESULTS: About 77% of those working in private clinics, a

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Mon Jun 01 2020
Journal Name
Journal Of Engineering
Reliability Analysis of Multibit Error Correcting Coding and Comparison to Hamming Product Code for On-Chip Interconnect
...Show More Authors

Error control schemes became a necessity in network-on-chip (NoC) to improve reliability as the on-chip interconnect errors increase with the continuous shrinking of geometry. Accordingly, many researchers are trying to present multi-bit error correction coding schemes that perform a high error correction capability with the simplest design possible to minimize area and power consumption. A recent work, Multi-bit Error Correcting Coding with Reduced Link Bandwidth (MECCRLB), showed a huge reduction in area and power consumption compared to a well-known scheme, namely, Hamming product code (HPC) with Type-II HARQ. Moreover, the authors showed that the proposed scheme can correct 11 random errors which is considered a high

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Oct 01 2020
Journal Name
International Communications In Heat And Mass Transfer
Thermal behaviour of the flow boiling of a complex nanofluid in a rectangular channel: An experimental and numerical study
...Show More Authors

View Publication
Scopus (24)
Crossref (24)
Scopus Clarivate Crossref
Publication Date
Tue May 31 2022
Journal Name
International Journal Of Research In Social Sciences & Humanities
A Critical Discourse Analysis Study of Silence in Selected Texts of Virginia Woolf
...Show More Authors

BN Rashid, Social Sciences, 2022

View Publication
Publication Date
Fri May 01 2020
Journal Name
Journal Of Physics: Conference Series
Frequency Dispersion of the Signal in the Recursive Digital Section of the Second Order
...Show More Authors
Abstract<p>The problems of modeling the signal and dispersion properties of a second order recursive section in the integer parameter space are considered. The formulation and solution of the section synthesis problem by selective and dispersive criteria using the methods of integer nonlinear mathematical programming are given. The availability of obtaining both positive and negative frequency dispersion of a signal in a recursive section, as well as the possibility of minimizing dispersion distortions in the system, is shown.</p>
View Publication
Scopus Crossref
Publication Date
Sun Jun 30 2024
Journal Name
Iraqi Journal Of Science
Telescope Mirror Cleaning Using Atmospheric Pressure Multi-Channel Radio Frequency Plasma Jet
...Show More Authors

     In this work, the surface of the telescope’s mirror is cleaned using an atmospheric-pressure radio frequency plasma jet (APRFPJ), which is generated by Argon gas between two coaxial metal electrodes. The RF power supply is set to 2 MHz frequencies with three different power levels: 20, 50, and 80 W. Carbon, that has adhered to the surface, can be effectively removed using the plasma cleaning technique, which also modifies any residual bonds. The cleaned surface was clearly distinguished using an optical emission spectroscopy (OES) technique and a water contact angle (WCA) analyzer for the activation property on their surfaces. The sample showed a super hydrophilic surface at an angle of 1° after 2.5 minutes of plasma tre

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sat Dec 05 2015
Journal Name
PrzeglĄd Elektrotechniczny
Power Amplifier Frequency Controller Using feedback control techniques for Bio-implanted Devices
...Show More Authors

View Publication
Scopus Crossref