Background: Measuring implant stability is an important issue in predicting treatment success. Dental implant stability is usually measured through resonance frequency analysis (RFA). Osstell® RFA devices can be used with transducers (Smartpeg™) that correspond to the implants used as well as with transducers designed for application with Penguin® RFA devices (Multipeg™). Aims: This study aims to assess the reliability of a MultiPeg™ transducer with an Osstell® device in measuring dental implant stability. Materials and Methods: Sixteen healthy participants who required dental implant treatment were enrolled in this study. Implant stability was measured by using an Osstell® device with two transducers, namely, Smartpeg™ and Multipeg™. Insertion torque was also measured and recorded as >50 and ≤50 N·cm. Unpaired t-test and Mann–Whitney U test were conducted to assess the relationships of the implant stability values obtained by the two transducers with insertion torque, whereas Pearson and Spearman's correlations were utilized to investigate correlations between the two transducers. Interclass correlation coefficients were applied to assess the reliability between the two transducers. Results: Implant stability measurements (primary and secondary) showed strong positive correlations between Smartpeg™ and Multipeg™. The reliability values between both transducers in primary and secondary implant stability measurements were 0.922 and 0.981, respectively. The use of both transducers revealed higher implant stability measurements for implants inserted with insertion torque > 50 N·cm than those inserted with insertion torque ≤ 50 N·cm. Conclusions: This study demonstrated that the Multipeg™ transducer is reliable in measuring the stability of dental implants using an Osstell® device.
Hepatitis, an inflammation of the liver, has a number of infectious and non-infectious causes. Two of the viruses that cause hepatitis (hepatitis A and E) can be transmitted through water and food; hygiene is therefore important in their control. First, to assess the importance of HAV and HEV as a possible diagnosis for clinically diagnosed patients with acute viral hepatitis. Second, to assess the prevalence of hepatitis A and E in all provinces of Iraq and study its association with age, gender. This study consisted of two groups: The first group consisted of 2975 patients with a clinical diagnosis of acute viral hepatitis. The second group consisted of a total of 9610 persons, which were recruited by surveying a nationally representative
... Show MoreSkeletal Class II malocclusion is commonly treated with functional appliances, but bulkiness and discomfort usually affect the compliance. Modifications of these appliances using clear thermoplastic materials could improve comfort and esthetics; though clinical evidence remains limited.
To assess the clinical effectiveness of a Modified Twin Block (MTB) appliance, fabricated from 2 mm biocompatible polyethylene terephthalate modified with Glycol
This paper involved the registration of 1,936 cases of infection of the Leishmania tropica parasite observed at hospitals and health centers in Ramadi, Fallujah, Baghdadi, and Hit during 2017. The results revealed that the highest rates of infection were found in Ramadi and Fallujah. The 1-10 years age group recorded the highest rate at 35.5%. There was no significant difference (p ≥ 0.05) between the sexes. December and January saw the highest rate of infection, where the rate in rural townships was found to be 65.5%, higher than in urban regions which saw a rate of 34.4%. Facial lesions were the most prominent area of infection, recorded at a rate of 41.3%. The study also included an examination of 180 rodents (94 mice and 86 black r
... Show MoreThe present paper describes a static model of malware detection and employs a tri-class prevention policy that operates on the EMBER 2024 Win64 partition. A LightGBM classifier trained on 1,040,000 samples and 804 static PE features achieves AUC-ROC = 0.9979, precision = 98.7%, recall = 97.4%, and F1 = 0.9805 on the temporally-split 240,000-sample test set. An innovative Tri-class Threshold Scheme (BLOCK/SUSPICIOUS/ALLOW) obtained by constrained F2-score optimisation on a separate validation set obtains 97.9% malware detection with 98.1% benign pass rate. Efficient model scoring is verified by mean per-sample model inference latency of 2.30 ms (P99: 2.70 ms) measured on pre-extracted EMBER features, future work is characterized by a complet
... Show MoreKE Sharquie, AA Noaimi, SJ Murtada…, Journal of Cosmetics, Dermatological Sciences and Applications, 2016 - Cited by 4
PID (proportional-integral-derivative) and Mu controllers are widely used in electro-hydraulic servo systems due to their effectiveness and ease of implementation. This paper explores using particle swarm optimization (PSO) for tuning traditional and robust PID controllers, along with D-K iteration for Mu controller tuning. Three controller types: conventional PID (CPID), robust PID (RPID), and structured singular value controllers are developed, while analyzing multiplicative uncertainty with six uncertain coefficients. Their findings indicated that both PID (CPID and RPID) and Mu controllers maintained system stability. Notably, the Mu controller can handle coefficient uncertainty without a pure integral term, while the RPID controller de
... Show MoreIn this paper, a novel flow control strategy which is the inlet throttled pump was used to design an angular velocity control system for rotary actuator. Inlet throttled systems have good performance in addition to their high efficiency compared to traditional valve controlled systems. The flow in the proposed system is adjusted by a valve that is positioned at the pump inlet with the purpose of reducing the energy loses across the valve. This regulated flow is used then to control the actuator angular velocity. The system was modeled and the open loop stability and performance were studied. In order to improve the system performance, Robust-Proportional-Integral-Derivative (RPID) and structured singular value (M@#@) controllers have been d
... Show MoreThis research describes the design & implementation of frequency synthesizer using single loop Phase lock loop with the following specifications: Frequency range (1.5 – 2.75) GHz,Step size (1 MHz), Switching time 36.4 µs, & phase noise @10 kHz = -92dBc & spurious -100 dBc
The development in I.C. technology provide the simplicity in the design of frequency synthesizer because it implements the phase frequency detector(PFD) , prescalar & reference divider in single chip. Therefore our system consists of a single chip contains (low phase noise PFD, charge pump, prescalar & reference divider), voltage controlled oscillator , loop filter & reference oscillator. The single chip
... Show More