Preferred Language
Articles
/
jbcd-3450
FEM: Mono-implant cement retained crown with two different adhesive materials
...Show More Authors

Background: The finite element method (FEM) is expected to be one of the most effective computational tools for measuring the stress on implant-supported restorations. This study was designed using the 3D-FEM to evaluate the effect of two adhesive luting types of cement on the occlusal stress and deformation of a hybrid crown cemented to a mono-implant. Materials and Method: The mono-screw STL file was imported into the CAD/CAM system library from a database supported by De-Tech Implant Technology. This was to assist in the accurate reproduction of details and design of a simulated implant abutment. Virtually, a digital crown was designed to be cemented on an abutment screw. A minimum occlusal thickness of 1mm and marginal fitting of 1.2mm was intended. An 80µm cement interface thickness for this study’s purposes was applied using U-Cem Premium and 3M RelyXTm adhesives. The FEA software meshed into tetrahedral elements. Two three-dimensional finite element models were simulated under different loads of 200N, 400N, 600N, 800N, 1000N, 1200N, and 1400N. Results: The results showed that the hybrid ceramic crown attached to a mono-implant with each adhesive cement exhibited comparable stress and strain. However, the amount of distortion was less when RelyX cement was used. Conclusion: Overall, it was advisable to use 3M RelyXTm adhesive cement up to 1400N load.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Dec 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Determination of Implant Primary Stability: A Comparison of the Surgeon’s Tactile Sense and Objective Measurements
...Show More Authors

Background: Evaluation and measurement of primary stability could be achieved by several methods, including the resonance frequency analysis (RFA) and implant insertion torque (IT) values. The need for a sufficient primary stability, guaranteed by an adequate insertion torque and implant stability quotient values, increased its importance mainly in one stage implants or in immediate loading protocols. The aims of this study was to find if there is a correlation between the peak insertion torque (PIT) and ISQ values of implants inserted in the jaws of different bone quality which regarded as two important clinical determinant factors for prediction of implant primary stability, and to evaluate and compare whether an experienced clinician cou

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jun 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Histological and histomorphometric studies of the effects of hyaluronic acid on osseointegration of titanium implant in rabbits
...Show More Authors

Background: One of the unique prosthesis for tooth or teeth replacement is the dental implant. Our attempt is using a biomaterial system that is easily obtained and applicable and has the ability to provoke osteoinductive growth factor to enhance bone formation at the site of application. One of these natural polymers is hyaluronic acid. Material and methods: Sixty machined surface implants from commercially pure titanium rod inserted in thirty NewZealand rabbits. Two implants placed in both tibia of each rabbit. The animals scarified at 1, 2 and 4 weeks after implantation (10 rabbits for each interval). For all of animals the right tibia’s implant was control (uncoated) and the left one was experimental (coated with 0.1ml Hyaluro

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Indian Journal Of Dental Research
Biomechanical finite element analysis of a single implant threaded in anterior and posterior regions of maxilla bone
...Show More Authors

Context: The ability of implant dentistry to be a successful alternative for edentulous patients has increased in the last decade. Clinical features such as osseointegration and stability, in addition to the endurance of the integration urged the researchers towards a better understanding of the design parameters that control long term success of the implants. It is therefore necessary to quantify the effect of changing implant design parameters on interface stress distribution within the maxilla bone. Methods and Materials: A 3D-finite element study was conducted to investigate the effect of changing implant shape parameters (implant body design and implant thread depth) on stress distribution while insertion of the implant in two diff

... Show More
View Publication
Scopus (12)
Crossref (13)
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
2nd International Conference For Engineering Sciences And Information Technology (esit 2022): Esit2022 Conference Proceedings
Determination of moisture content in some materials using linear attenuation coefficient
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Thu Sep 03 2009
Journal Name
Engineering And Technology Journal
Study on the properties of composite materials produced by centrifugal casting
...Show More Authors

سمير خلف فياض * و محسن طالب د.نوال عزت عبد اللطيف*, مجلة الهندسة والتكنولوجيا, 2010

View Publication Preview PDF
Publication Date
Fri Jan 20 2023
Journal Name
Iranian Journal Of Materials Science And Engineering
First-Principles Analysis of Cr-Doped SrTiO3 Perovskite as Optoelectronic Materials
...Show More Authors

This contribution evaluates the influence of Cr doping on the ground state properties of SrTiO3 Perovskite using GGA-PBE approximation. Results of the simulated model infer agreement with the previously published literature. The modification of electronic structure and optical properties due to Cr3+ doping levels in SrTiO3 has been investigated. Structural parameters infer that Cr3+ doping alters the electronic structures of SrTiO3 by shifting the conduction band through lower energies for the Sr and Ti sites. Substituting Ti site by Cr3+ results the energy gap in being eliminated revealing a new electrical case of conducting material for the system. Furthermore, it has been noticed that Cr doping either at Sr or Ti positions could effectiv

... Show More
Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Detection capability Alttafaria for some materials using a bacterial mutagenesis system
...Show More Authors

Tested effective Alttafaria some materials used for different purposes, system a bacterial mutagenesis component of three bacterial isolates belonging to different races and materials tested included drug Briaktin

View Publication Preview PDF
Publication Date
Tue Jun 14 2016
Journal Name
Al-academy
Employment educational and artistic style of fiction in the textbook materials
...Show More Authors

Find goal to detect educational and technical staffing of style fiction in book reading school materials so determine the current research on the specific book reading in fourth grade of primary for the academic year 2014 issued by the Ministry of Education / Republic Iraq stories. Come in the importance of research to draw attention to the best of these stories and strengthened, and the negative deny it and claim his deportation in order to protect the thought of the learner, and the study may contribute to the development of some frameworks to write a story appropriate for elementary school. This McCann within the first chapter The second chapter included the theoretical framework has been contained on two main sections included the co

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Apr 01 2011
Journal Name
Journal Of Engineering
REMOVAL OF PHOSPHORUS FROM WASTEWATER BY ADSORPTION ONTO NATURAL IRAQI MATERIALS
...Show More Authors

This study focused on treating wastewater to remove phosphorus by adsorption onto naturaland local materials. Burned kaolin, porcelinite, bauxite and limestone were selected to be testedas adsorption materials.The adsorption isotherms were evaluated by batch experiments, studyingthe effects of pH, temperature and initial phosphorus concentration. The results showed that at pH6, temperature 20°C and 300 mg/l initial phosphorus concentration; the sorption capacity was0.61, 9, 10 and 13 mg/g at 10 h contact time, for burned kaolin, porcelanite, limestone and bauxiterespectively. As the pH increased from 2 to 10 the removal efficiency for the materials differs inbehaviour. The removal efficiency increased from 40 to 90 % for limestone, and dec

... Show More
Crossref (3)
Crossref
Publication Date
Sun Apr 08 2018
Journal Name
Al-khwarizmi Engineering Journal
Physical and Morphological Properties of Hard- Soft Ferrite Functionally Graded Materials
...Show More Authors

  Functionally graded materials (FGMs), with ceramic –ceramic constituents are fabricated using powder technology techniques. In this work three different sets of FGMs samples were designed in to 3 layers, 5 layers and 7 layers. The ceramic constituents were represented by hard ferrite (Barium ferrite) and soft ferrite (lithium ferrite). All samples sintered at constant temperature at 1100oC for 2 hrs. and characterized by FESEM. Some physical properties were measured for fabricated FGMs include apparent density, bulk density, porosity, shrinkage and hardness. The results indicated that the density increase with the increase the number of layer. Lateral shrinkage is one of the important parameter f

... Show More
View Publication Preview PDF
Crossref (1)
Crossref