Background: Periodontal diseases are inflammatory disorders caused by the accumulation of oral biofilm and the host response to this accumulation which characterized by exaggerated leukocytes and neutrophils attraction to the sites of inflammation by chemoattractants which are a very important part of the pathogenesis of periodontal diseases. This study aimed to determine and compare the clinical periodontal parameters and the leukocyte cell types in the peripheral blood between patients with gingivitis and periodontitis with different severities compared to healthy controls. Materials and methods: This study included 150 male subjects aged between 35-50 years. They were divided into three groups: gingivitis group (n=30), periodontitis patients (n=90) which subdivided into Mild =30 patients, Moderate =30 patients, Severe =30 patients and a control group (n=30) with clinically healthy periodontium. Clinical periodontal parameters were recorded ((plaque index (PLI), gingival index (GI), bleeding on probing (BOP), probing pocket depth (PPD) and clinical attachment level (CAL)). Blood samples were collected then an automated blood analyzer evaluated leukocyte cell types. Results: Significant differences in The counts of neutrophils and lymphocytes exhibited significant differences among the study groups and subgroups. On contrary, differences in monocytes, eosinophils, and basophils counts were not significant. Additionally, severity of periosontitis was significantly correlated with the mean counts of the various leukocyte cell types; however, clinical periodontal characteristics did not show such correlation with these inflammatory cells. Conclusion: This study demonstrated that periodontal disease with different severities is associated with possible episodes of bacteremia that originate from periodontal lesions which mediate inflammatory conditions that in turn causing changes in the systemic markers especially leukocytes cells types.
Three different distribution modules of silicon solar cells in a panel are used in this study . Each module consists of five identical circular silicon solar cells of radius (5cm) and then the total panel areas are identical. The five solar cells are arranged in the panel in different shapes: circular, triangular and rectangular .The efficiency for these three panel distribution are measured indoor and outdoor. The results show that the efficiency is a function of the cells distribution.
Corrosion rate tests were carried out on carbon steel under concentration cells conditions of oxygen and sodium chloride. The effect of aeration in one compartment on the corrosion rate of both coupled metals was determined. In addition, the effects of time and temperatures on the corrosion rate of both coupled metals and galvanic currents between them were investigated. Corrosion potentials for the whole range of operating conditions under concentration cell conditions were also studied. The results showed that under aeration condition, the formation of concentration cell caused a considerable corrosion rate of the Carbon steel specimens coupled in different concentrations of O2 and NaCl due to the galvanic effect
... Show MoreIn this paper, developed Jungck contractive mappings into fuzzy Jungck contractive and proved fuzzy fixed point for some types of generalize fuzzy Jungck contractive mappings.
Thirty nine hyperlipoproteinemic (HPLic) male subject aged (48-63) year not on any of the lipid lowering drugs, attending out patient clinic at Baghdad Teaching Hospital, were included in the present study, in addition to twenty two normolipidimic male subjects of matched age were included as control throughout this study. The first part of this study was devoted to the classification of the HPLic subjects according to the serum lipid and lipoprotein profile following defined criteria. The lipid parameter including total cholesterol (TC), triglyceride (TG), high density lipoprotein (HDL) and low density lipoprotein (LDL) were investigated in serum of HPLic subjects included in the study. The classification was performed according to Fred
... Show MoreAtopic dermatitis (atopic eczema), is a common familial chronic inflammatory skin disease, determined by xerosis, itching, scaly and erythematous skin lesions, and high serum levels of IgE. Between 10 to 20% of children and 1 to 3% of adults worldwide affected by it and has negative medical and social effect on patients and their families. To evaluate the effectiveness of Phytosterol Fraction of Chenopodium Murale on induced atopic dermatitis (AD) of mice; Forty mice were included in the study, divided in to four groups (10 mice/group): apparently healthy, induced AD without treatment, induced AD treated with Tacrolimus 0.1% ointment, and induced AD treated with Phytosterol Fraction of Chenopodium Murale cream 3% topica
... Show MoreIn this paper, the maximum likelihood estimates for parameter ( ) of two parameter's Weibull are studied, as well as white estimators and (Bain & Antle) estimators, also Bayes estimator for scale parameter ( ), the simulation procedures are used to find the estimators and comparing between them using MSE. Also the application is done on the data for 20 patients suffering from a headache disease.
The present work involved preparation of new substituted and unsubstituted and poly imides (1-17) using reaction of acryloyl chloride with different amides (aliphatic ,aromatic) in the presence of a suitable solvent and amount tri ethyl amine (Et3N) with heating – the structure confirmation of all polymers were proved using FT-IR,1H-NMR,C13NMR and UV spectroscopy ,thermal analysis (TG) for some polymers confirmed their thermal stabilities . Other physical properties including softening and melting points, PH and solubility of the polymers were also measured
Critical buckling and natural frequencies behavior of laminated composite thin plates subjected to in-plane uniform load is obtained using classical laminated plate theory (CLPT). Analytical investigation is presented using Ritz- method for eigenvalue problems of buckling load solutions for laminated symmetric and anti-symmetric, angle and cross ply composite plate with different elastic supports along its edges. Equation of motion of the plate was derived using principle of virtual work and solved using modified Fourier displacement function that satisfies general edge conditions. Various numerical investigation were studied to exhibit a convergence and accuracy of the present solution for considering some design parameters such as edge
... Show More