Background: Gastroesophageal reflux disease, is a quite prevalent gastrointestinal disease, among which gastric content (excluding the air) returns into the oral cavity. Many 0ral manifestations related t0 this disease include tooth wear, dental caries also changes in salivary flow rate and pH. This study was conducted among gastroesophageal reflux disease patients in order to assess tooth wear in relation to salivary flow rate and pH among these patients and the effect of gastroesophageal reflux disease duration on this relation. Materials and methods: One hundred patients participate in this cross-sectional study for both genders and having an age range of 20-40 years old, patients had been endoscopically identified as having gastroesophageal reflux disease using the classification of Los Angeles (LA), who were attending the Gastroenterology and Hepatology Teaching Hospital in Baghdad. and divided into two groups: group A with grade severity mucosal breakage not longer than 5 mm and Group B with grade severity mucosal breakage more than 5 mm long, Smith and Knight (1984) tooth wear index criteria were used for the assessment of tooth wear. For measurement of salivary flow rate and pH, saliva sample (unstimulated) had been collected. Results: Of the entire sample (90%) were having tooth wear. Tooth wear was higher in grade B severity than in grade A severity among patients with gastroesophageal reflux disease duration of two years or less, while it was higher in grade A than in grade B among patients with a duration of more than two years but all these results were statistically non-significant. Salivary flow rate and pH showed a non-significant reduction with increasing gastroesophageal reflux disease severity for both of groups concerning disease duration. The correlation of total tooth wear with salivary flow rate and pH was a significantly weak negative correlation in grade A, while a nonsignificant weak negative correlation in grade B. Conclusions: The findings of the present study concluded that patients with gastroesophageal reflux disease recorded a high occurrence of tooth wear and there was a negative correlation of tooth wear with salivary flow rate and pH among patients with gastroesophageal reflux disease.
Piroxicam (PIR) is a nonsteroidal anti-inflammatory drug of oxicam category, used in gout, arthritis, as well as other inflammatory conditions (topically and orally). PIR is practically insoluble in water, therefore the aim is prepare and evaluate piroxicam as liquid self-nanoemulsifying drug delivery system to enhance its dispersibility and stability. The Dispersibilty and Stability study have been conducted in Oil, Surfactant and Co-surfactant for choosing the best materials to dissolve piroxicam. The pseudo ternary phase diagrams have been set at 1:1, 2:1, 3:1 as well as 4:1 ratio of surfactants and co-surfactants, also there are 4 formulations were prepared by using various concentrations of transcutol HP, cremophore EL and triacetin
... Show MoreThe printed Arabic character recognition are faced numerous challenges due to its character body which are changed depending on its position in any sentence (at beginning or in the middle or in the end of the word). This paper portrays recognition strategies. These strategies depend on new pre-processing processes, extraction the structural and numerical features to build databases for printed alphabetical Arabic characters. The database information that obtained from features extracted was applied in recognition stage. Minimum Distance Classifier technique (MDC) was used to classify and train the classes of characters. The procedure of one character against all characters (OAA) was used in determination the rate
... Show MoreIn this paper, we have examined the influence of heat- transfer on the magnetohydrodynamics oscillatory flow of Williamson fluid during porous medium for two types of geometries "Poiseuille flow and Couette flow". We use perturbation technique in terms of the Weissenberg number to obtain explicit forms for velocity profiles. The results that obtained are illustrated by graphs.
A newly developed analytical method characterized by its speed and sensitivity for the determination of metformin-HCl via the formation of complex for metformin-HCl-OH--copper(II) ion from the gel bead system by continuous flow injection analysis. The method is based on the imbedded copper(II) ion in the gel bead structure can be used in the reaction for the formation of red –magneta colour complex(λmax. =530nm) formed by direct reaction of the drug with the released copper (II) ion from the gel bead in alkaline medium. Linear dynamic range for the absorbance versus metformin concentration was 0.001-1 mmol.L-1 while C.O.D was (r2% =95.33%) . The L.O.Q was 0.868mmol.L-1.L.O.D (S/N=3)=0.5μmol.L-1 from the step wise dilution for the min
... Show MoreLow incoming discharge upstream of Samarra-Al Tharthar System leads to sediment accumulation and forming islands, especially an island upstream of Al Tharthar Regulator. This island and the sedimentation threaten the stability of the structure and reduce the efficiency of the system. This study aims to hydraulically identify the sedimentation problem mentioned above, to find solutions of how to control the sediment problems, and to develop the capacity of
the system for 500 years return period flood of 15060 m3/s. Surface Water Modeling System (SMS10.1) with two dimensional depth average models (RMA-2) software were used to simulate and analyze the system. The results of analysis showed that the maximum permissible discharge through t
This work consists of a numerical simulation to predict the velocity and temperature distributions, and an experimental work to visualize the air flow in a room model. The numerical work is based on non-isothermal, incompressible, three dimensional, k turbulence model, and solved using a computational fluid dynamic (CFD) approach, involving finite volume technique to solve continuity, momentum and energy equations, that governs the room’s turbulent flow domain. The experimental study was performed using (1/5) scaled room model of the actual dimensions of the room to simulate room air flow and visualize the flow pattern using smoke generated from burnt herbs and collected in a smoke generator to delivered through
... Show MoreEchocardiography is a widely used imaging technique to examine various cardiac functions, especially to detect the left ventricular wall motion abnormality. Unfortunately the quality of echocardiograph images and complexities of underlying motion captured, makes it difficult for an in-experienced physicians/ radiologist to describe the motion abnormalities in a crisp way, leading to possible errors in diagnosis. In this study, we present a method to analyze left ventricular wall motion, by using optical flow to estimate velocities of the left ventricular wall segments and find relation between these segments motion. The proposed method will be able to present real clinical help to verify the left ventricular wall motion diagnosis.
This experimental study focuses on scouring in box culvert inlets under steady-state conditions and at different percentages of blockage ranging from 0% to 65%, and also looks at the hydraulics of water in the culvert. The investigation shows that the blockage of the culverts has influenced the scouring pattern at the blocked culverts' entrances. Ten experiments were carried out at the laboratory to see how blockage impacts the scouring pattern upstream of a box culvert during steady flow. Both partially blocked and unblocked cases were implemented in this study. The experimental tests were done until the equilibrium scour occurred, which took about 3.5 hours of water flow to reach equilibrium conditions. The results r
... Show MoreA new, simple, sensitive and fast developed method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation a burgundy color complex between methyldopa andammonium ceric (IV) nitrate in aqueous medium using long distance chasing photometer NAG-ADF-300-2. The linear range for calibration graph was 0.05-8.3 mmol/L for cell A and 0.1-8.5 mmol/L for cell B, and LOD 952.8000 ng /200 µL for cell A and 3.3348 µg /200 µL for cell B respectively with correlation coefficient (r) 0.9994 for cell A and 0.9991 for cell B, RSD % was lower than 1 % for n=8. The results were compared with classical method UV-Spectrophotometric at λ max=280 n
... Show MoreThe calibration of a low-speed wind tunnel (LSWT) test section had been made in the present work. The tunnel was designed and constructed at the Aerodynamics Lab. in the Mechanical Engineering Department/University of Baghdad. The test section design speed is 70 m/s. Frictional loses and uniformity of the flow inside the test section had been tested and calibrated based on the British standards for flow inside ducts and conduits. Pitot-static tube, boundary layer Pitot tube were the main instruments which were used in the present work to measure the flow characteristics with emphasize on the velocity uniformity and boundary layer growth along the walls of the test section. It is found that the maximum calibrated velocity for empty test s
... Show More