Background: Manuka honey (MH) is a mono-floral honey derived from the Manuka tree (Leptospermum scoparium). MH is a highly recognized for its non-peroxide antibacterial activities, which are mostly related to its unique methylglyoxal content (MGO) in MH. The beneficial phytochemicals in MH is directly related to their favorable health effects, which include wound healing, anticancer, antioxidant, and anti-inflammatory properties. Aims: The purpose of this study was to evaluate the effect of MH on pro-inflammatory cytokines (IL-8 and TNF-α) in patients with gingivitis and compare it with chlorhexidine (CHX) and distilled water (DW). Materials and Methods: This study was a randomized, double blinded, and parallel clinical trial. Forty-five young participants aged (20–40) years were randomly selected and allocated into three groups: MH, CHX, and DW mouthwash groups. Each participant was given a random bottle. Five milliliters each of honey-based mouthwash formulation, CHX mouthwashes (0.2%) and DW were used twice daily for 21 days. All the participants were examined twice, once on the zero day (base line) and once after 21 days. Before and after each participant's mouthwash use IL-8 and TNF-α were measured using enzyme-linked immunosorbent assay (ELISA). Results: The results revealed a drop in the level of interleukin-8 in the manuka honey group which was statistically significant, but the decrease in the same biomarker in the chlorhexidine group was insignificant statistically. TNF-α levels were found to be insignificantly reduced in both the MH and CHX groups (P˃0.05). The DW group, on the other hand, obtained the opposite outcome in both biomarkers. Conclusion: Mouthwash containing MH had an anti-inflammatory impact, indicating an immunomodulatory action. These signs may be encouraging and promising for the use of MH in treating gingivitis.
Copper electrodeposition by electrorefining process in acidic sulfate media contains 40 g/l of cupric ions and 160 g/l of sulfuric acid was achieved to study the influence of the operating parameters on cathode purity, surface morphology, deposition rate, current efficiency and power consumption. These operating parameters and there ranges are: current density 200, 300 and 400 A/m2, electrolyte temperature 35, 50 and 65 oC, electrodes spacing 15, 30 and 45 mm and electrolyte residence time 6, 4 and 2 h were utilized. XRF, SEM and EDX analyses were attained to clarify the properties of the produced cathode.
Background: Hypothyroidism is a clinical syndrome prevalent in women, even those of reproductive age. Ovarian reserve can be defined as the number and quality of follicles in the ovary at any given time. Evaluation of ovarian reserve is recommended for patients at risk of decreased ovarian reserve. Objective: This study aims to evaluate the effect of hypothyroidism on ovarian reserve in Iraqi women by hormonal measurements of serum anti-mullerian hormones AMH, FSH, and LH. Subjects and methods: This case–control study was carried out at the Department of Biochemistry, College of Medicine, University of Baghdad, in collaboration with Endocrinology and Diabetes Clinic, Baghdad Teaching Hospital, and National Center for Teaching Labo
... Show MoreZinc Oxide thin film of 2 μm thickness has been grown on glass substrate by pulsed laser deposition technique at substrate temperature of 500 oC under the vacuum pressure of 8×10-2 mbar. The optical properties concerning the absorption, and transmission spectra were studied for the prepared thin film. From the transmission spectra, the optical gap and linear refractive index of the ZnO thin film was determined. The structure of the ZnO thin film was tested with X-Ray diffraction and it was formed to be a polycrystalline with many peaks.
Thermal performance of closed wet cooling tower has been investigated experimentally and theoretically
in this work. The theoretical model based on heat and mass transfer equations and heat and mass transfer balance equations which are established for steady state case. A new small indirect cooling tower was used for conducting experiments. The cooling capacity of cooling tower is 1 kW for an inlet water temperature of 38oC, a water mass velocity 2.3 kg/m2.s and an air wet bulb temperature of 26oC. This study investigates the relationship between saturation efficiency, cooling capacity and coefficient of performance of closed wet cooling tower versus different operating parameters such wet-bulb temperature, variable air-spray water fl
This paper details the process of designing, analysing, manufacturing, and testing an integrated solid-state hydrogen storage system. Analysis is performed to optimise flow distribution and pressure drop through the channels, and experimental investigations compare the effects of profile shape on the overall power output from the fuel cell. The storing of hydrogen is given much attention in the selection of a storage medium, and the effect of a cooling system to reduce the recharging time of the hydrogen storage vessel. The PTFE seal performed excellently, holding pressure over 60 bar, despite requiring changing each time the cell is opened. The assembly of the vessel was simple and straightforward, and there was no indication of pressure
... Show MoreThe research aim was to observe the distribution pattern of
This intervention study is composed on 55 patients at Saddam Center for Cardiac Surgery (Aben-Albetar) throughout the period from 1st of July 1997 to 15th of January 1999. The study aimed to evaluate the effectiveness of constructed nursing education program on reduction of complications and improving recovery among patients with Coronary Artery Bypass Graft (CABG) surgery through the application of repeated measures. The sample is divided into 27 patients who received the nursing educational program (study group) and 28 patients who continued to receive regular care (controls). Based on previous research meth
This study was conducted to determine the effects of concentration of hydrochloric acids, temperature, and time on the hydrolysis of soya proteins (defatted soya flour) by determining the value of total protein nitrogen concentration, and amino nitrogen concentration of protein, peptides, and amino acids, and then calculated the hydrolysis rate of proteins.
The variables of the conditions of hydrolysis process was achieved in this study with the following range value of tests parameter:
- Concentration of HCl solution ranged between 1-7 N,
- Hydrolysis temperature ranged between 35-95 °C, and
- The time of hydroly