Preferred Language
Articles
/
jbcd-3309
In vitro assessment of bracket adhesion post enamel conditioning with a novel etchant paste
...Show More Authors

Background: 37% phosphoric acid (PA) is the traditional enamel etching technique prior to bracket ‎adhesion, yet it has been implicated in numerous enamel injuries. The purpose of the current study was to create a calcium phosphate (CaP) etching paste in a ‎‎simplified capsule ‎formula that can underpin clinically ‎adequate bracket bond strength ‎without jeopardizing the ‎integrity of enamel upon ‎the debracketing procedure. Materials and Methods: micro-sized hydroxyapatite (HA) powder was mixed with 40% PA solution to prepare ‎experimental acidic CaP paste. Sixty human premolars were ‎assigned into two groups of 30 each. ‎Enamel conditioning was accomplished using 37% PA-gel‎ for control group and CaP paste for experimental group. Each group was further divided into two subgroups regarding the water storage (WS) period (24 h and 30 days). Shear bond strength (SBS) test conducted with examination of debonded surfaces for adhesive remnants and enamel damage using a digital microscope. Results: CaP paste produced significantly lower SBS values than PA (p < 0.01), yet sufficient for clinical use. PA etching caused often cracked enamel surfaces with excessive ‎retention of adhesive remnants (mainly ARI scores 2 and 3). Contrarily, enamel treated with the experimental CaP paste exhibited smooth, ‎unblemished surfaces mostly clean of adhesives residues (scores 0 and 1). Conclusion: a newly developed CaP paste in a capsule formula fosters ‎clinically adequate bracket ‎adhesion with a sustained bonding performance, allows a harmless bracket removal with ‎minimal or no adhesive residues on debonded surfaces; thus, it can be introduced as a suitable ‎alternative to PA‎.  

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Oct 07 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of different staining materials on color stability of sapphire brackets bonded with different types of light cure orthodontic adhesives (An in vitro study)
...Show More Authors

Background: The demand for better esthetic during orthodontic treatment has increased nowadays, so orthodontists starting using esthetic arch wires, brackets and ligatures.Tooth colored brackets were introduced in different types of materials. Sapphire ceramic brackets are one type of esthetic brackets and their color stability remains the main concern for the clinicians and patients at the same time. The present study design to evaluate the effect of three different staining materials (pepsi, black tea and cigarette smoke) on the stainability of sapphire ceramic brackets bonded with three types of light cure orthodontic adhesives which include: Resilience, Enlight and Transbond. Materials and Methods: The sample consisted of three hundre

... Show More
View Publication Preview PDF
Publication Date
Sat Jul 08 2017
Journal Name
Research Journal Of Pharmaceutical , Biological And Chemical Sciences
Assessment activity and Partial purification of Alkaline phosphatase (AIP) from sera of patients with celiac disease
...Show More Authors

Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
The Effect of 532 nm Diode Pumped Solid State (DPSS) Laser in Combination with Safranin on the Growth of Pseudomonas aeruginosa and Staphylococcus aureus in Vitro
...Show More Authors

The effect of 532nm Diode Pumped Solid State (DPSS) laser at power density of 5.234 W/cm2 on the growth of Gram-negative Pseudomonas aeruginosa and Gram-positive Staphylococcus aureus was evaluated. These bacteria were isolated from samples taken from burn and infected wound areas of 55 patients admitted to the burn-wound unit in Al-Kindy teaching hospital in Baghdad during the period from October 2012 to March 2013. Each isolate was identified using microscopic, cultural and biochemical methods. A standard bacterial suspension was prepared for each isolate. Serial dilutions were then prepared and a dilution of 10-5 was selected. Irradiation experiments included four groups: (L-P-) bacterial suspension in saline solution, (L-P+) bacteria

... Show More
View Publication Preview PDF
Publication Date
Wed Nov 01 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Assessment of ellagic acid action in 5-fluorouracil induced intestinal mucositis: Assessment of ellagic acid action in 5-fluorouracil induced intestinal mucositis
...Show More Authors

The intestinal mucositis define as inflammation and ulceration in the gastrointestinal tract wall and in some case in the oral cavity these cause by treatment with antineoplastic drug like 5-fluorouracil and Irinotecan and other types of chemotherapeutics drugs , 5-Fluorouracil-induced intestinal mucositis (IM) is consider as one of the more common tumor issue .it cause series of undesirables symptoms like severe diarrhea ,abdominal pain , stomach uncomfortable and other. The aim of this current study to see how ellagic acid act to  Attenuates 5-FU-Induced Intestinal Mucositis and  Diarrhea in Mice . we induced the intestinal mucositis by injected the mice intraperitoneally in 5-fluorouracil about 50mg per kg daily for

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (6)
Scopus Crossref
Publication Date
Wed Oct 07 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Tensile force measurement by using different lingual retainer wires, bonding materials types and thickness (A comparative in vitro study)
...Show More Authors

Background: The bonded orthodontic retainer constructed from multistrand wire and composite is an efficient esthetic retainer, which can be maintained long-term. Clinical failures of bonded orthodontic retainers, most commonly at the wire/composite interface, have been reported. This in vitro investigation aimed to evaluate the tensile forces of selected multistrand wires and composite materials that are available for use in the construction of bonded fixed retainers. Materials and Methods: The study sample includes 120 wires with three types of retainer wires (3 braided strands\ Orthotechnology, 8 braided strands\ G&H Orthodontics, 6 coaxial strands\ Orthoclassic wires), two types of adhesive (flowable\ Orthotechnology, non flowable\ G&H O

... Show More
View Publication Preview PDF
Publication Date
Sun Aug 20 2023
Journal Name
International Journal Of Drug Delivery Technology
Role of higB-higA Novel Genes in Antibiotics Resistance of Pseudomonas aeruginosa
...Show More Authors

Background: Pseudomonas aeruginosa is a devious pathogen with the tendency to prompt many acute and serious chronic diseases. This study aims to detect novel genes (Toxins-Antitoxins II system), especially; higB and higA encoded from P. aeruginosa by PCR technique and the relation between these genes and antibiotic resistance of P. aeruginosa. Methods: This study detected 50 isolates of P. aeruginosa from distinct clinical sources. The most common origin of isolates was (44%) burn swabs, (22%) urine culture, (12%) wound swabs, (14%) sputum, and (8%) ear swabs. The bacteria were isolated using implantation MacConkey agar and blood agar, as well as biochemical tests including oxidase test, catalase test then VITEK-2 System of P. aerug

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Biochemical & Cellular Archives
Assessment of uric acid in patients of end-stage renal disease with hypertension and diabetic nephropathy and the risk of cardiovascular diseases
...Show More Authors

The relationship of hyperuricemia to kidney disease, diabetes, hypertension and the risk of cardiovascular diseases remain controversial. The aim of this study is to evaluate the use of uric acid (UA) levels to find the higher risk of cardiovascular disease (CVD) in patients with end stage renal disease that have diabetic nephropathy (DN), nephropathy with hypertension (NH) and patients with both diabetic nephropathy with hypertension (DNH). This study deals with 115 patients with end-stage renal disease under hemodialysis sub-grouped into 35 patients with (DN), 40 patients with (NH), and 40 patients with (DNH). Some biochemical parameters were determined in the serum of all participants such as HbA1c, fasting blood glucose (FBG), UA, urea,

... Show More
Scopus (1)
Scopus
Publication Date
Thu Mar 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Different Pouring Interval of Conventional Impression on the Marginal Accuracy of Full Contour Zirconia Crowns in Comparison with Digital Impression (An in vitro study)
...Show More Authors

Background: The success and maintenance of indirect dental restorations is closely related to the marginal accuracy, which is affected by many factors like preparation design, using of different fabrication techniques, and the time of taking final impression and pouring it. The purpose of this in vitro study was to evaluate the effect of different pouring time of conventional impression on the vertical marginal gap of full contour zirconia crowns in comparison with digital impression technique. Materials and Methods: Forty sound recently extracted human permanent maxillary first premolar teeth of comparable size and shape were collected. Standardized preparation of all teeth samples were carried out to receive full contour zirconia crown re

... Show More
View Publication
Crossref
Publication Date
Fri Dec 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Different Pouring Interval of Conventional Impression on the Marginal Accuracy of Full Contour Zirconia Crowns in Comparison with Digital Impression (An in vitro study)
...Show More Authors

Background: The success and maintenance of indirect dental restorations is closely related to the marginal accuracy, which is affected by many factors like preparation design, using of different fabrication techniques, and the time of taking final impression and pouring it. The purpose of this in vitro study was to evaluate the effect of different pouring time of conventional impression on the vertical marginal gap of full contour zirconia crowns in comparison with digital impression technique. Materials and Methods: Forty sound recently extracted human permanent maxillary first premolar teeth of comparable size and shape were collected. Standardized preparation of all teeth samples were carried out to receive full contour zirconia crown re

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Baghdad Science Journal
In Vitro Cytotoxicity Study of Pt Nanoparticles Decorated TiO2 Nanotube Array
...Show More Authors

Titanium dioxide nanotubes were synthesized by anodizing Ti sheets in the ethylene glycol solution and were covered in Pt nanoparticles onto the surface of TiO2NTs using electrodeposition method from using five derivatives of Mannich base Pt complexes which have been used as precursor of platinum. The mean size, shape, elemental composition of the titanium dioxide nanotubes and platinum deposited on the template were evaluated by different techniques such as field emission scanning electron microscope (FE-SEM), transmission electron microscopy (TEM), X-ray diffraction pattern (XRD), and energy dispersive X-ray (EDX) technique. From all these analyses, the TiO2NTs prepared and Ptnanoparticles deposited on it were ide

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (3)
Scopus Clarivate Crossref