Manual probing and periodontal charting are the gold standard for periodontal diagnosis that have been used in practice over a century. These methods are affordable and reliable but they are associated with some drawbacks that cannot be avoided. Among these issues is their reliance on operator’s skills, time-consuming and tedious procedure, lack sensitivity especially in cases of early bone loss, and causing discomfort to the patient. Availability of a wide range of biomarkers in the oral biofluids, dental biofilm, and tissues that potentially reflect the periodontal health and disease accurately encouraged their use as predictive/diagnostic/monitoring tools. Analysing biomarkers during care-giving to the patient using chairside kits is known as Point of Care (POC) testing. Introduction of POC in periodontal practice could provide more flexibility and add further dimensions to the process of diagnosis and tailoring more precise treatment plan for the patients. This review aimed to highlight available POC testing used for periodontal diagnosis and disease prediction/monitoring
Background: Accurate measurement of a patient’s height and weight is an essential part of diagnosis and therapy, but there is some controversy as to how to calculate the height and weight of patients with disabilities. Objective: This study aims to use anthropometric measurements (arm span, length of leg, chest circumference, and waist circumference) to find a model (alternatives) that can allow the calculation of the height and the body weight of patients with disabilities. Additionally, a model for the prediction of weight and height measurements of patients with disabilities was established. Method: Four hander patients aged 20-80 years were enrolled in this study and divided into two groups, 210 (52.5%) male and 190 (47.5%) fe
... Show MoreThe worsening of environmental problems has led to them being addressed by many entities, the most important of which are the top regulators. Federal Board of supreme audit Office is one of the most important regulators in Iraq. The problem of the research was the fundamental question of the extent to which the Federal Financial Supervisory Office was committed to implementing and exercising environmental control over the audited ones. The refore, the research was based on the main objective of questioning the role of the Federal Financial Supervisory Office in the exercise of environmental control and the compliance of those under its control, by identifying the antosai standards for environmental control, particularly the stand
... Show MoreThe study aims at explaining the extent to which the principles of educational management reform contribute to Ibn Ashour in achieving educational management reform and the extent to which the pillars of the Kingdom's Vision 2030 in the field of Education in achieving the educational management reform. The study also aims to provide a future vision of what the educational administrative reform and its results should be in the Kingdom during the next ten years. To achieve the goals of the study, the researcher followed two approaches: on the theoretical side, he relied on applying the content analysis method. As for the applied side, the researcher adopted the Delphi method by two questionnaires to ask (36) participants from the experts a
... Show MoreBACKGROUND: Acute appendicitis (AA) remains a complex case even for experienced surgeons. Rate of negative appendectomy is 5–40% and delayed intervention result in perforated appendicitis in 5–30% of cases. AIM: The aim of the study was to evaluate NPT as a marker for the diagnosis of AA concerning its severity. And compare the diagnostic value of it with the ALV scoring system. METHODS: One hundred twenty patients presented with signs and symptoms of AA and underwent appendectomy, only 84 patients proved to be AA by histopathological examination, were included in the study. Blood samples for neopterin (NPT) estimation and Alvarado (ALV) score was calculated. Control group consists of 45 healthy individual. RESULTS: NPT levels were s
... Show More
Buildings such as malls, offices, airports and hospitals nowadays have become very complicated which increases the need for a solution that helps people to find their locations in these buildings. GPS or cell signals are commonly used for positioning in an outdoor environment and are not accurate in indoor environment. Smartphones are becoming a common presence in our daily life, also the existing infrastructure, the Wi-Fi access points, which is commonly available in most buildings, has motivated this work to build hybrid mechanism that combines the APs fingerprint together with smartphone barometer sensor readings, to accurately determine the user position inside building floor relative to well-known lan
... Show MoreThe calibration of a low-speed wind tunnel (LSWT) test section had been made in the present work. The tunnel was designed and constructed at the Aerodynamics Lab. in the Mechanical Engineering Department/University of Baghdad. The test section design speed is 70 m/s. Frictional loses and uniformity of the flow inside the test section had been tested and calibrated based on the British standards for flow inside ducts and conduits. Pitot-static tube, boundary layer Pitot tube were the main instruments which were used in the present work to measure the flow characteristics with emphasize on the velocity uniformity and boundary layer growth along the walls of the test section. It is found that the maximum calibrated velocity for empty test sect
... Show More
Concentrated research topic in addressing variable vital to the work of offices of inspectors general, construction and scale effectiveness and efficiency is the organizational structure, which are important as is obvious to any researcher in the management and organization and this variable would affect the exercise task supervision and inspection of financial and administrative corruption and combat efficiently, Thus this effect will be placed in the fold ability to achieve goals. That the creation of the organizational structure and requirements to achieve harmony between its properties is creating step towards success. This research aims to analyze the characteristics and style o
The calibration of a low-speed wind tunnel (LSWT) test section had been made in the present work. The tunnel was designed and constructed at the Aerodynamics Lab. in the Mechanical Engineering Department/University of Baghdad. The test section design speed is 70 m/s. Frictional loses and uniformity of the flow inside the test section had been tested and calibrated based on the British standards for flow inside ducts and conduits. Pitot-static tube, boundary layer Pitot tube were the main instruments which were used in the present work to measure the flow characteristics with emphasize on the velocity uniformity and boundary layer growth along the walls of the test section. It is found that the maximum calibrated velocity for empty test s
... Show MoreThe field experiment was conducted with the aim of developing and testing an automatic sprayer for agricultural spray experiments and studying the effect of spray pressure, spray speed and spray height on the spraying process. The effects of the major spraying factors (pressure, speed, and height) on the spraying performance of the automatic sprayer were studied. This study included several traits: First - the drop sizes - Second - the penetration of the spray into the vegetation cover - Third, the spray wasted. The results showed: - First: - Increase in coverage percentage when using the first speed, 2 km / h, which amounted to 26.85%. An increment in the spraying penetration of the vegetation cover was observed at the second speed
... Show MoreBackground: Deep vein thrombosis is a multi causal disease and its one of most common venous disorder, but only one quarter of the patients who have signs and symptoms of a clot in the vein actually have thrombosis and need treatment .The disease can be difficult to diagnose. Venous ultrasound in combination with clinical finding is accurate for venous thromboembolism, its costly because a large number of patients with suspicious signs and symptoms. Venography still the gold standard for venous thromboembolism but it is invasive. The D-dimer increasingly is being seen as valuable tool rolling out venous thromboembolism and sparing low risk patients for further workup.Objectives: this study has designed the role of D-dimer to confirm diag
... Show More