Preferred Language
Articles
/
jbcd-3234
Determination of Surface Roughness and Accuracy of Alginate Impression Material Disinfected by Immersion
...Show More Authors

Background: This study was conducted to evaluate the surface roughness and dimensional accuracy of commercially obtainable alginate impression material in terms of imbibition after immersion in two different media. Materials and method: Two disinfecting agents, ethanol 70% and povidone-iodine 4%, were used to access the dimensional accuracy and surface roughness of alginate impression material. Weights of specimen discs of alginate impressions were measured before and immediately after immersion to gain a measure of imbibition. For surface roughness, disinfected specimens rectangle was examined before and after disinfection. Results: Minimal changes in weight were observed after disinfection, but a statistically non-significant difference was found before and after immersion. It did not affect the surface roughness of alginate impression material Conclusion: Disinfection of alginate impression material with ethanol and povidone iodine had no significant effect on dimensional accuracy and surface roughness.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Dec 31 2020
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
DISPERSIVE LIQUID LIQUID MICRO EXTRACTION SPECTROPHOTOMETRIC DETERMINATION OF TELMESARTAN AND IRBESARTAN IN PHARMACEUTICALS SAMPLES: DISPERSIVE LIQUID LIQUID MICRO EXTRACTION SPECTROPHOTOMETRIC DETERMINATION OF TELMESARTAN AND IRBESARTAN IN PHARMACEUTICALS SAMPLES
...Show More Authors

The current work is characterized by simplicity, accuracy and high sensitivity Dispersive liquid - Liquid Micro Extraction (DLLME). The method was developed to determine Telmesartan (TEL) and Irbesartan (IRB) in the standard and pharmaceutical composition. Telmesartan and Irbesartan are separated prior to treatment with Eriochrom black T as a reagent and formation ion pair reaction dye. The analytical results of DLLME method for linearity range (0.2- 6.0) mg /L for both drugs, molar absorptivity were (1.67 × 105-    5.6 × 105) L/ mole. cm, limit of detection were (0.0242and0.0238), Limit of quantification were (0.0821and0.0711), the Distribution coefficient were

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 04 2011
Journal Name
Baghdad Science Journal
Determination of bacterial contamination of milk using fluorometry
...Show More Authors

The aim of this paper is to determine the feasibility of using fluorometric methods as an indicator for quality and contamination of milk with E.coli bacteria, and selection the suitable wavelength to be used with laser induced auto fluorescence. Three groups of milk samples were used in this study: Fresh pasteurized milk samples, milk samples containing different concentration of E.coli bacteria which were added artificially, and milk samples that were kept in refrigerator for 3-5 days. Thirteen excitation wavelengths were used to get the emission spectra for all milk samples using spectroflourometer .The results showed that the emission spectra at 275nm excitation wavelength gave a good differentiation between these three groups.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Nov 04 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Determination of Quality of Life for Adult Patients
...Show More Authors

Objective: The study aimed to determine quality of life domains for adult patients with limbs loss and to identify
the association between quality of life domains and demographic characteristics and medical information.
Methodology: A descriptive study was carried out at Baghdad artificial limb center, Al-Salam medical
rehabilitation center, Al-Ghadeer medical rehabilitation center and the rheumatoid and medical rehabilitation
center for the period from September 2007 to April 2008. A purposive ''non- probability'' sample of (200)
patients with limbs loss. Questionnaire form was constructed for the purpose of the study. Data were collected
through the application of the questionnaire and interview technique. Data were a

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 25 2020
Journal Name
International Journal Of Drug Delivery Technology
Development of a Simple Colorimetric Determination of Dexamethasone
...Show More Authors

A simple, environmentally benign, cost-effective, and sensitive colorimetric determination for the pharmaceutical drug dexamethasone sodium phosphate (DXP) has been developed by the formation of a colored complex with fluoranil. The process was sensitive and linear over the range 1 to 40 μg/mL, excellent correlation coefficient 0.9989, recovery% 99.80 ± 1.3, limit of detection (LOD) and limit of quantification (LOQ) were 0.23 and 0.9 μg/mL, respectively, and good RSD ~1.63%. The experimental conditions were optimized after an intensive study. The approach was validated statistically for the quantification of the analyte in its pure and/or pharmaceutical form. Despite the proposed approach is selective, it still can be applied for

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (6)
Scopus Crossref
Publication Date
Tue May 27 2025
Journal Name
Scientific Journal Of Sport And Performance
impact of mental games on improving shooting accuracy among young basketball players in Iraqi clubs
...Show More Authors

This study investigates the effectiveness of mental games in enhancing shooting accuracy among young basketball players. Initially, baseline shooting accuracy was assessed through tests conducted prior to a three-week intervention involving mental games. A follow-up test revealed a significant improvement in participants' shooting accuracy following the intervention. Given the noticeable differences in the new shooting scores compared to the initial assessments, a second set of pre-intervention tests was conducted. These tests reaffirmed the significant enhancement in shooting accuracy, substantiating the hypothesis that mental games positively affect performance. The findings highlight the importance of these intervention programs

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Tue May 27 2025
Journal Name
Scientific Journal Of Sport And Performance
impact of mental games on improving shooting accuracy among young basketball players in Iraqi clubs
...Show More Authors

This study investigates the effectiveness of mental games in enhancing shooting accuracy among young basketball players. Initially, baseline shooting accuracy was assessed through tests conducted prior to a three-week intervention involving mental games. A follow-up test revealed a significant improvement in participants' shooting accuracy following the intervention. Given the noticeable differences in the new shooting scores compared to the initial assessments, a second set of pre-intervention tests was conducted. These tests reaffirmed the significant enhancement in shooting accuracy, substantiating the hypothesis that mental games positively affect performance. The findings highlight the importance of these intervention programs

... Show More
Preview PDF
Crossref (4)
Crossref
Publication Date
Thu Mar 01 2018
Journal Name
Nauchforum
THE PROBLEM OF TRANSLATING METAPHOR IN AN ARTISTIC TEXT (ON THE MATERIAL OF RUSSIAN AND ARABIC LANGUAGES)
...Show More Authors

THE PROBLEM OF TRANSLATING METAPHOR IN AN ARTISTIC TEXT (ON THE MATERIAL OF RUSSIAN AND ARABIC LANGUAGES)

Publication Date
Fri Jun 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of phosphate ester addition on transverse strength and hardness of heat cured acrylic denture base material
...Show More Authors

Background: acrylic resin denture base consider a common denture base material for its acceptable cost, aesthetic and easy processing but still has disadvantages including easy of fracture and low impact strength. Material and method: The experimental group was prepared by addition of 15% phosphoric acid 2-hydroxyethyl methacrylate ester (PA2HEME) with polymethyl methacrylate monomer; the experimental groups was compared with the control one. The specimens were prepared according to ADA specification No. 12 with dimension 65 mm x 10 mm x2.5 mm (length x width x thickness respectively). The prepared specimens were tested by three-point flexural strength utilizing Instron Universal Testing Machine (WDW, Layree Technology Co.), Shore D hard

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Baghdad Science Journal
Simultaneous Determination of Binary Mixture of Estradiol and Progesterone Using Different Spectrophotometric Methods
...Show More Authors

Four rapid, accurate and very simple derivative spectrophotometric techniques were developed for the quantitative determination of binary mixtures of estradiol (E2) and progesterone (PRG) formulated as a capsule. Method I is the first derivative zero-crossing technique, derivative amplitudes were detected at the zero-crossing wavelength of 239.27 and 292.51 nm for the quantification of estradiol and 249.19 nm for Progesterone. Method II is ratio subtraction, progesterone was determined at λmax 240 nm after subtraction of interference exerted by estradiol. Method III is modified amplitude subtraction, which was established using derivative spectroscopy and mathematical manipulations. Method IIII is the absorbance ratio technique, absorba

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Dec 14 2011
Journal Name
Journal Of Intelligent Material Systems And Structures
Analytical determination of characteristic frequencies and equivalent circuit parameters of a piezoelectric bimorph
...Show More Authors

Piezoelectric structures are nowadays used in many different applications. A better understanding of the influence of material properties and geometrical design on the performance of these structures helps to develop piezoelectric structures specifically designed for their application. Different equivalent circuits have been introduced in the literature to investigate the behaviour of piezoelectric transducers. The model parameters are usually determined from measurements covering the characteristic frequencies of the piezoelectric transducer. This article introduces an analytical technique for calculating the mechanical and electrical equivalent system parameters and characteristic frequencies based on material properties and geom

... Show More
View Publication
Scopus (21)
Crossref (19)
Scopus Clarivate Crossref