Preferred Language
Articles
/
jbcd-3216
12- months color stability of direct resin composite veneers in anterior teeth: Clinical trial
...Show More Authors

Background: This clinical trial aims to evaluate the color changes of direct resin composite veneer (DCV) restorations based on spectrophotometric analysis of 4 different types of resin composites between the baseline immediately after polishing and after one year of follow-up. Materials and methods: 28 patients were assessed for eligibility for participation, aged between 18 and 38 years old, who indicated for DCV restorations in anterior maxillary teeth were considered for participation in this study. In total, 25 patients who met the inclusion criteria were selected (6 males and 19 females, mean age: 20.9 at the time of restoration placement), and 3 patients were excluded. Participants were divided into four groups based on the type of composite resin used for restorations. Group 1 nanohybrid Ips Empress direct (Ivoclar Vivadent)](IPS) (13 restorations/6 patients), group 2 microfilled [Essentia (GC cooperation Japan)](ES) (14 restorations / 7 patients), group 3 supra-nano filled [ Estelite ∑ Quick (Tokuyama, Tokyo, Japan)](EQ) (17 restorations / 7 patients) and group 4 nanofill [Filtek Ultimate (3M ESPE)](FU) (13 restorations / 5 patients). Baseline Color measurements were performed with a spectrophotometer immediately after finishing and polishing (baseline), and after one year of recall, color change (ΔE) from baseline values and after one year of follow-up of DCVs were calculated according to CIELab color coordinates. For this, a silicone mold was fabricated for each patient and used as a guide for each measurement to standardize the site of the readings. Statistical analysis of the data was applied using the Kruskal-Wallis test with Dunn-Bonferroni posthoc test after controlling the distribution of data in terms of normality with the Shapiro Wilk test. Results: At the end of one year,25 participants(57restorations) were followed up. The mean ΔE of IPS, EQ, and FU composites were higher than the ES composite resin, but there was no statically significant difference between all types of composites (P> 0.05). There was no statistically significant difference in the mean ΔL* between any types of composite resin (p> 0.05). There was a significant change in Δa* and Δb* after a one-year recall for all the types of DCV restorations (p < 0.05). Conclusion: After one year of follow-up, the spectrophotometer measurements of direct resin composite veneer restorations, it was concluded no difference between the mean ΔE of ES, IPS, FU, and EQ resin composite. ES (Microfilled hybrid) showed a lower mean ΔE value compared to the other groups. All groups of resin composite showed color changes within clinically acceptable levels after a one-year follow-up.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Annals Of Tropical Medicine And Public Health
The impact of JAK2V617F allelic burden on clinical and laboratory parameters in patients with myeloproliferative neoplasms
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Mon Jan 08 2024
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Recurrence Rate of Pleomorphic Adenoma in Minor Salivary Glands After Surgical Excision: A Retrospective Clinical Study
...Show More Authors

Background: Pleomorphic adenoma of the minor salivary gland is a rare benign tumor. It commonly occurs in the hard and soft palates. Treatment by surgical excision achieved success in improving the patient’s health. Objective: To evaluate the recurrence rate after surgical treatment of pleomorphic adenoma in minor salivary glands. Methods: This retrospective study included patients who attended the Maxillofacial Surgery Unit in Ghazi Al-Hariri Hospital, Baghdad, from 2019 to 2021, complaining of soft tissue lumps involving the soft and hard palate, buccal mucosa, and upper lip. After the provisional diagnosis of these lesions, a total surgical excision of the tumor with a safe margin of 1 mm was performed, and the biopsy was sent

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Mon Jan 08 2024
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Recurrence Rate of Pleomorphic Adenoma in Minor Salivary Glands After Surgical Excision: A Retrospective Clinical Study
...Show More Authors

Background: Pleomorphic adenoma of the minor salivary gland is a rare benign tumor. It commonly occurs in the hard and soft palates. Treatment by surgical excision achieved success in improving the patient’s health. Objective: To evaluate the recurrence rate after surgical treatment of pleomorphic adenoma in minor salivary glands. Methods: This retrospective study included patients who attended the Maxillofacial Surgery Unit in Ghazi Al-Hariri Hospital, Baghdad, from 2019 to 2021, complaining of soft tissue lumps involving the soft and hard palate, buccal mucosa, and upper lip. After the provisional diagnosis of these lesions, a total surgical excision of the tumor with a safe margin of 1 mm was performed, and the biopsy was sent for hist

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Wed Jan 30 2013
Journal Name
Al-kindy College Medical Journal
Disc Battery-The escalating risk of ingestion by children in IraqAnd subsequent clinical events and complications.
...Show More Authors

Background: Disc battery ingestion is a common
serious problem in Iraq. It increase in the last years
because of the increase in number of electronic toys
that uses these batteries. These batteries contains
many types of irritant chemicals that increases the
risk of it's ingestion.
Methods:We reviewed the medical records of
children aged between 1year and 7 years
old admitted to Surgical Specialty Hospital/Baghdad
Medical City due to disc battery ingestion from
January 2007 through December 2010). The diagnosis
of disc battery ingestion was based upon history,
clinical symptoms, and results of imaging studies.
The clinical data reviewed included sex, age, clinical
manifestation and duration of sy

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of the Effect of Bone Morphogenetic Protein-2 on Stability of Dental Implant
...Show More Authors

Background: The healing period for bone–implant contact takes 3–6 months or even longer. Application of Escherichia coli-derived recombinant human bone morphogenetic protein-2 (ErhBMP-2) to implant surfaces has been of great interest on osseointegration due to its osteoinductive potential. The objective of this study was to evaluate the effect of ErhBMP-2 on implant stability. Materials and methods: A total of 48 dental implants were inserted in 15 patients. Twenty four implants coated with 0.5 mg/ml ErhBMP-2 (study group). The other 24 implants were uncoated (control group). Each patient was received at least two dental implants at the same session. Both groups were followed with repeated implant stability measurements by me

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jun 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Some Remineralization Materials and Resin Infiltration (ICON) on the Depth of White Spot Lesions
...Show More Authors

Background: White spot lesions (WSLs) are subsurface enamel demineralization manifested as white opacities which had an esthetic problem. The purpose of this in-vitro study was to evaluate the lesion depth improvement of WSLs following application of fluoride varnish, tooth mousse and resin infiltration (ICON). Materials and methods: Artificial WSLs were created on 120 premolar teeth using demineralization solution with pH (4-4.5). Samples randomly allocated into four groups; fluoride varnish, tooth mousse, ICON and untreated group. Groups were discolored in Cola and orange juice for 24 hours. Teeth were ground sectioned by longitudinal cutting then these sections examined and photographed under stereomicroscope at 12X magnification then an

... Show More
View Publication
Crossref (6)
Crossref
Publication Date
Thu Jun 19 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of light curing tip distance on the curing depth of bulk fill resin based composites
...Show More Authors

Background: This in vitro study measure and compare the effect of light curing tip distance on the depth of cure by measuring vickers microhardness value on two recently launched bulk fill resin based composites Tetric EvoCeram Bulk Fill and Surefil SDR Flow with 4 mm thickness in comparison to Filtek Z250 Universal Restorative with 2 mm thickness. In addition, measure and compare the bottom to top microhardness ratio with different light curing tip distances. Materials and Method: One hundred fifty composite specimens were obtained from two cylindrical plastic molds the first one for bulk fill composites (Tetric EvoCeram Bulk Fill and Surefil SDR Flow) with 4 mm diameter and 4 mm depth, the second one for Filtek Z250 Universal Restorative

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 09 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Study the Effect of Addition of Some Oxides on the Mechanical properties on Unsaturated Polyester Resin Compsites
...Show More Authors

This study included preparation for the unsaturated polyester samples before and after reinforced by Alumina oxide powder and copper oxide powder of different volume fraction amounting (3%,5%,8%). And this reearch included study of some of mechanical properties such as (hardness,compressive and wear).The results showed that increase of the hardness and compressive strength after the reinforced and increase with the volume fraction increase.As the wear test show that the wear rate increases with applied load from the different load(5,10,15)N,and the wear rate decreases with the volume fraction increase.

View Publication Preview PDF
Publication Date
Wed Aug 01 2018
Journal Name
Journal Of Research In Medical And Dental Science
Evaluation of Bond Strength of Acrylic Artificial Teeth with Unreinforced and Nano Silica Reinforced Denture Base Material after Chemical Disinfection
...Show More Authors

Soaking dentures with disinfection solutions is an effective way of keeping dentures in a healthy status; however, immersions in these solutions have a negative effect on the bond strength of denture base and denture teeth. The aim of this study was to evaluate the bond strength between denture acrylic teeth and heat-cured Poly (methyl methacrylate) denture base material (with and without nano silica) after disinfection with different chemical disinfectants for a simulated period of six months. One hundred specimens of maxillary central incisors attached to PMMA were divided into two groups; 50 specimens of PMMA without nano silica and 50 specimens of PMMA reinforced with 5 wt% of nano silica. Specimens of each group were immersed in five i

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 01 2024
Journal Name
International Immunopharmacology
Evaluation of interleukins (IL-1α, IL-1Ra, IL-12, IL-17A, IL-31, and IL-33) and chemokines (CXCL10 and CXCL16) in the serum of male patients with ankylosing spondylitis
...Show More Authors

View Publication
Scopus (1)
Crossref (2)
Scopus Clarivate Crossref