Background: This clinical trial aims to evaluate the color changes of direct resin composite veneer (DCV) restorations based on spectrophotometric analysis of 4 different types of resin composites between the baseline immediately after polishing and after one year of follow-up. Materials and methods: 28 patients were assessed for eligibility for participation, aged between 18 and 38 years old, who indicated for DCV restorations in anterior maxillary teeth were considered for participation in this study. In total, 25 patients who met the inclusion criteria were selected (6 males and 19 females, mean age: 20.9 at the time of restoration placement), and 3 patients were excluded. Participants were divided into four groups based on the type of composite resin used for restorations. Group 1 nanohybrid Ips Empress direct (Ivoclar Vivadent)](IPS) (13 restorations/6 patients), group 2 microfilled [Essentia (GC cooperation Japan)](ES) (14 restorations / 7 patients), group 3 supra-nano filled [ Estelite ∑ Quick (Tokuyama, Tokyo, Japan)](EQ) (17 restorations / 7 patients) and group 4 nanofill [Filtek Ultimate (3M ESPE)](FU) (13 restorations / 5 patients). Baseline Color measurements were performed with a spectrophotometer immediately after finishing and polishing (baseline), and after one year of recall, color change (ΔE) from baseline values and after one year of follow-up of DCVs were calculated according to CIELab color coordinates. For this, a silicone mold was fabricated for each patient and used as a guide for each measurement to standardize the site of the readings. Statistical analysis of the data was applied using the Kruskal-Wallis test with Dunn-Bonferroni posthoc test after controlling the distribution of data in terms of normality with the Shapiro Wilk test. Results: At the end of one year,25 participants(57restorations) were followed up. The mean ΔE of IPS, EQ, and FU composites were higher than the ES composite resin, but there was no statically significant difference between all types of composites (P> 0.05). There was no statistically significant difference in the mean ΔL* between any types of composite resin (p> 0.05). There was a significant change in Δa* and Δb* after a one-year recall for all the types of DCV restorations (p < 0.05). Conclusion: After one year of follow-up, the spectrophotometer measurements of direct resin composite veneer restorations, it was concluded no difference between the mean ΔE of ES, IPS, FU, and EQ resin composite. ES (Microfilled hybrid) showed a lower mean ΔE value compared to the other groups. All groups of resin composite showed color changes within clinically acceptable levels after a one-year follow-up.
When we try to navigate the experiment in search of the repressed and to find the dream of creativity by changing the modularity of the presentation, and the relationship of the characters with the rest of the elements according to a visual vision that reflects the product of the presentation system through the formation of visions and ideas within the textual structure.
We find that the expression of the theatrical act may need to exclude narrative dialogues and turn them into a tangible visual language. Physical and visual expression, and movement review, thus producing a “picture language” through which it is possible to form a new vision, and this is called (image theater), which translates the language of dialogue through lig
Finite element modeling of transient temperature distribution is used to understand physical phenomena occurring during the dwell (penetration) phase and moving of welding tool in friction stir welding (FSW) of 5mm plate made of 7020-T53 aluminum alloy at 1400rpm and 40mm/min.
Thermocouples are used in locations near to the pin and under shoulder surface to study the welding tool penetration in the workpiece in advance and retreate sides along welding line in three positions (penetrate (start welding) , mid, pullout (end welding)).
Numerical results of ANSYS 12.0 package are compared to experimental data including axial load measurements at different tool rotational speeds (710rpm.900rpm.1120rpm and 1400rpm) Based on the experiment
In the present paper, the features of democratization of vocabulary in the language of mass media are tackled. Particularly, the functions of this phenomenon in the context of language as an ontological reality are analysed. As well, the growing role of the language of the media, and the language of politics as an integral part pertaining to it, is noted. Further, attention is paid to the excessive saturation of the language of the media along with the literary language, by means of evaluation which may include negative results.
In this concern, scholars had different views, specifically in relation to the use of colloquial vocabulary along with some vernacular profess
... Show MoreBreast tumors patients generally have more oxidative stress than normal females. This was clear from a highly significant elevation (P<0.05) in malondialdehyde level in RBCs, serum and tissue of all patients groups with breast cancer as compared with control group. In this study we had found that free radicals in malignant breast tumors were higher than benign tumors, therefore the MDA might be used as a marker for prognosis of the disease.
This study aimed to evaluate good manufacturing practices in food safety of ten different restaurants in the Al-Karkh area of Baghdad, Iraq. Forty samples collected from were collected from knives, food cutting boards, tables, hands and nails workers in restaurants. In addition. 70 food handlers were selected. Through structured interviews, information on the checklist for Good Manufacturing Practices in Food Safety, Food handlers’ general checklist for good hygiene, and Personal Hygiene Checklist were collected. The overall viable bacterial count before Good Hygiene Practices was significantly higher (P<0.05) than the total bacterial counts after Good Hygiene Practices. The highest viable bacterial counts before Good Hygiene P
... Show MoreWaveform transport of Pseudo plastic fluid in complaint symmetric channel with culvature properties has designed. The efforts of magnetic force, which has applied by radiate direction in the analysis, is considered by using the influence of Hartmann number. Walls properties with slip conditions on velocity distribution as well as stream function are used. The analysis of" heat and mass transfer" has taken into account. More popularized factual constraints known by the convective conditions are applied. The partial differential equations of motion, temperature and concentration is reduced under the simulation of low quantity of wave number and Reynolds number and then transformed to or
The types of traditional houses vary from region to region according to physical and non-physical circumstances, and Sulaymaniyah city is characterized by a type of traditional houses that differ significantly from those in most cities and regions neighboring are always different from the general pattern that is prevalent in the region and the Muslim world.
The aim of this research is to study the cause of this difference or distinction in the traditional houses in Sulaimaniyah city, by comparing the most common models in these houses and comparing them with the general models of village houses that originally existed in the region to relaize the convergence and contrast between them. The research was based on a co
... Show MoreBackground: Low-level laser therapy (LLLT) has been extensively applied to improve wound healing due to some biostimulatory properties presented by laser arrays apparently able to accelerate the repair of soft tissue injuries. However, the role of proinflammatory interlukines not been studied yet. IL_1 ? represent one of the most important poroinflammatory interlukines that involved in wound healing. The goal of this study was to investigate the effect of 790-805nm diode laser on the expression of IL_1 ? during wound healing in mice. Materials and Methods: Standard-sized wounds (1.5cm) were carried out in the face of 96 white albino mice. Half of them underwent LLLT treatment (360 J/cm 2) at 790-805 nm delivered immediately after wound pro
... Show More