Background: This clinical trial aims to evaluate the color changes of direct resin composite veneer (DCV) restorations based on spectrophotometric analysis of 4 different types of resin composites between the baseline immediately after polishing and after one year of follow-up. Materials and methods: 28 patients were assessed for eligibility for participation, aged between 18 and 38 years old, who indicated for DCV restorations in anterior maxillary teeth were considered for participation in this study. In total, 25 patients who met the inclusion criteria were selected (6 males and 19 females, mean age: 20.9 at the time of restoration placement), and 3 patients were excluded. Participants were divided into four groups based on the type of composite resin used for restorations. Group 1 nanohybrid Ips Empress direct (Ivoclar Vivadent)](IPS) (13 restorations/6 patients), group 2 microfilled [Essentia (GC cooperation Japan)](ES) (14 restorations / 7 patients), group 3 supra-nano filled [ Estelite ∑ Quick (Tokuyama, Tokyo, Japan)](EQ) (17 restorations / 7 patients) and group 4 nanofill [Filtek Ultimate (3M ESPE)](FU) (13 restorations / 5 patients). Baseline Color measurements were performed with a spectrophotometer immediately after finishing and polishing (baseline), and after one year of recall, color change (ΔE) from baseline values and after one year of follow-up of DCVs were calculated according to CIELab color coordinates. For this, a silicone mold was fabricated for each patient and used as a guide for each measurement to standardize the site of the readings. Statistical analysis of the data was applied using the Kruskal-Wallis test with Dunn-Bonferroni posthoc test after controlling the distribution of data in terms of normality with the Shapiro Wilk test. Results: At the end of one year,25 participants(57restorations) were followed up. The mean ΔE of IPS, EQ, and FU composites were higher than the ES composite resin, but there was no statically significant difference between all types of composites (P> 0.05). There was no statistically significant difference in the mean ΔL* between any types of composite resin (p> 0.05). There was a significant change in Δa* and Δb* after a one-year recall for all the types of DCV restorations (p < 0.05). Conclusion: After one year of follow-up, the spectrophotometer measurements of direct resin composite veneer restorations, it was concluded no difference between the mean ΔE of ES, IPS, FU, and EQ resin composite. ES (Microfilled hybrid) showed a lower mean ΔE value compared to the other groups. All groups of resin composite showed color changes within clinically acceptable levels after a one-year follow-up.
This research is devoted to study the effect of different in weight percentage of Sio2 particles and glass fibers (5, 10, 15, 20) wt. % on the wear rate epoxy resin. The results show that the value of hardness increase with the increase for the weight percentage of reinforcing particles and fibers, while the wear rate decrease with the increase the load level of the reinforcing particles and fibers . The largest value of the hardness, and the lowest value of the wear rate for epoxy reinforced with 20% of SiO2, the wear rate increase in general with increasing the applied load.
ABSTRACT Background: resin cement type and intraoral temperature fluctuations may affect the fracture performance of successful zirconia restorations. To fill this gap, the purpose of this study is to evaluate and compare the influence of thermocycling on fracture resistance and mode of failure of monolithic zirconia crowns luted with Rely X™ U200 and BreezeTMself-adhesive resin cements as well as imply the effect of adding 2 % of polylysine (PLS) to these cements. Materials: 64 maxillary premolars were milled out of zirconia blocks using CAD/CAM milling system. They were divided into four groups (n = 16) according to the cement type. Four different resin cements were used (RelyXTMU200, Breeze™, RelyX™ U200 with 2 % PLS
... Show MoreThe study aimed to prepare rehabilitation exercises using some rubber ropes for people with partial rupture of the anterior cruciate ligament, to recognize their effect on the recovery of motor tides and to reduce the pain of those with partial rupture of the anterior cruciate ligament of the knee joint, and adopted the experimental method by designing the experimental and controlled groups on a sample of those with partial rupture of the anterior cruciate ligament of men (30-35) One year of those who attend the Physiotherapy Center/Rafidain University College of 12 injured were deliberately selected from their community of origin by (100%), and after determining the measuring tools and preparation of exercises applied with rubber r
... Show MorePatients with decompensated cirrhosis have typically prescribed a combination of therapeutic and prophylactic medications. Polypharmacy increases the probability of medication errors and drug related problems. Clinical pharmacists are highly effective at identifying, resolving, and preventing clinically important drug-related problems in their patients' care. The objectives of the study were the identification and classification of drug-related problems, as well as the discussion of these problems with health care providers (physicians, pharmacists, and nurses) and patients. Reduce their incidence as effectively as possible and educate all research participants on the significance of following their prescribed drug regimen
... Show MoreA composite section is made up of a concrete slab attached to a steel beam by means of shear connectors. Under positive and negative bending moment, part of the slab will act as a flange of the beam, resisting the longitudinal compression or tension force. When the spacing between girders becomes large, it is evident that the simple beam theory does not strictly apply because the longitudinal stress in the flange will vary with distance from the girder web, the flange being more highly stressed over the web than in the extremities. This phenomenon is termed "shear lag". In this paper, a nonlinear three-dimensional finite element analysis is employed to evaluate and determine the actual effective slab width of the composite steel-concrete
... Show MoreAbstract: Background: High percentage of diabetes patients complain from post extraction hemorrhage. Many types of hemostatic materials are used to stop bleeding after teeth extraction: diode lasers are good hemostatic agents owing to their highly absorption by hemoglobin therefore they are used in soft tissue procedures with relatively no effects on dental hard tissues due to their poorly absorption by water and hydroxyapatite. Objectives: The aim of this study is to evaluate the efficiency of diode laser to assist the clot formation after tooth extraction for type II diabetes patients with minimum temperature elevation to prevent periodontal destruction. Materials and methods: From 12 type II diabetes patients (7 males and 5 females wi
... Show MoreBuckling analysis of composite laminates for critical thermal (uniform and linear) and mechanical loads is reported here. The objective of this work is to carry out theoretical investigation of buckling analysis of composite plates under thermomechanical loads, and experimental investigation under mechanical loads. The analytical investigation involved certain mathematical preliminaries, a study of equations of orthotropic elasticity for classical laminated plate theory (CLPT), higher order shear deformation plate theory (HSDT) , and numerical analysis (Finite element method), then the equation of motion are derived and solved using Navier method and Levy method for symmetric and anti-symmetric cross-ply and angle-ply laminated plates t
... Show MoreA common approach to the color image compression was started by transform
the red, green, and blue or (RGB) color model to a desire color model, then applying
compression techniques, and finally retransform the results into RGB model In this
paper, a new color image compression method based on multilevel block truncation
coding (MBTC) and vector quantization is presented. By exploiting human visual
system response for color, bit allocation process is implemented to distribute the bits
for encoding in more effective away.
To improve the performance efficiency of vector quantization (VQ),
modifications have been implemented. To combines the simple computational and
edge preservation properties of MBTC with high c