Preferred Language
Articles
/
jbcd-3216
12- months color stability of direct resin composite veneers in anterior teeth: Clinical trial
...Show More Authors

Background: This clinical trial aims to evaluate the color changes of direct resin composite veneer (DCV) restorations based on spectrophotometric analysis of 4 different types of resin composites between the baseline immediately after polishing and after one year of follow-up. Materials and methods: 28 patients were assessed for eligibility for participation, aged between 18 and 38 years old, who indicated for DCV restorations in anterior maxillary teeth were considered for participation in this study. In total, 25 patients who met the inclusion criteria were selected (6 males and 19 females, mean age: 20.9 at the time of restoration placement), and 3 patients were excluded. Participants were divided into four groups based on the type of composite resin used for restorations. Group 1 nanohybrid Ips Empress direct (Ivoclar Vivadent)](IPS) (13 restorations/6 patients), group 2 microfilled [Essentia (GC cooperation Japan)](ES) (14 restorations / 7 patients), group 3 supra-nano filled [ Estelite ∑ Quick (Tokuyama, Tokyo, Japan)](EQ) (17 restorations / 7 patients) and group 4 nanofill [Filtek Ultimate (3M ESPE)](FU) (13 restorations / 5 patients). Baseline Color measurements were performed with a spectrophotometer immediately after finishing and polishing (baseline), and after one year of recall, color change (ΔE) from baseline values and after one year of follow-up of DCVs were calculated according to CIELab color coordinates. For this, a silicone mold was fabricated for each patient and used as a guide for each measurement to standardize the site of the readings. Statistical analysis of the data was applied using the Kruskal-Wallis test with Dunn-Bonferroni posthoc test after controlling the distribution of data in terms of normality with the Shapiro Wilk test. Results: At the end of one year,25 participants(57restorations) were followed up. The mean ΔE of IPS, EQ, and FU composites were higher than the ES composite resin, but there was no statically significant difference between all types of composites (P> 0.05). There was no statistically significant difference in the mean ΔL* between any types of composite resin (p> 0.05). There was a significant change in Δa* and Δb* after a one-year recall for all the types of DCV restorations (p < 0.05). Conclusion: After one year of follow-up, the spectrophotometer measurements of direct resin composite veneer restorations, it was concluded no difference between the mean ΔE of ES, IPS, FU, and EQ resin composite. ES (Microfilled hybrid) showed a lower mean ΔE value compared to the other groups. All groups of resin composite showed color changes within clinically acceptable levels after a one-year follow-up.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Feb 10 2019
Journal Name
Iraqi Journal Of Physics
Study of the mechanical properties of Iron-Epoxy composite materials
...Show More Authors

Iron-Epoxy composite samples were prepared by added
different weight percentages (0, 5, 10, 15, and 20 wt %) from Iron
particles in the range of (30-40μm) as a particle size. The contents
were mixed carefully, and placed a circular dies with a diameter of
2.5 cm. Different mechanical tests (Shore D Hardness, Tensile
strength, and Impact strength ) were carried out for all samples. The
samples were immersed in water for ten weeks, and after two weeks
the samples were take-out and drying to conducting all mechanical
tests were repeated for all samples. The hardness values increased
when the Iron particle concentration increased while the Impact
strength is not affected by the increasing of Iron particles
c

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
Effect of plasma jet on the water and hydrogen peroxide that used for assisted teeth bleaching
...Show More Authors

In this work the interaction of plasma jet with water and hydrogen peroxide liquids used for assisted teeth bleaching by plasma jet had been study. A homemade plasma jet system was used. The plasma jet supply by 15 W electrical power generated by high voltage power supply of 9.6 kV peak to peak and frequency of 33 kHz .this power supply generate high electric field on electrodes that would be enough to ionize the argon gas. Some important agents were study such as the effect of the Ar gas flow rates on the length of the plasma jet, the influence of plasma jet on some properties of water and two hydrogen peroxide concentrations 25 % and 30 % like pH, conductivity and liquid temperature for different exposure time. The liquids temperature

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue May 23 2023
Journal Name
Journal Of Engineering
Serviceability Performance of Externally Prestressed Steel-Concrete Composite Girders
...Show More Authors

The behavior of externally prestressed composite beams under short term loading has been studied. A computer program developed originally by Oukaili to evaluate curvature is modified to evaluate the deflection of prestressed composite beam under flexural load. The analysis model based on the deformation compatibility of entire structure that allows to determine the full history of strain and stress distribution along cross section depth, deflection and stress increment in the external tendons .
The evaluation of curvatures for the composite beam involves iterations for computing the strains vectors at each node at any loading stage. The stress increment determined using equations depended on the member deflection at points of connecti

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Dec 31 2022
Journal Name
Al-kindy College Medical Journal
Molecular Microbiology in Clinical Practice: Current and Future Applications: Molecular Microbiology
...Show More Authors

Technological advances have yielded new molecular biology-based methods for the diagnosis of infectious diseases.  The newest and most powerful molecular diagnostic tests are available at regional and national reference laboratories, as well as at specialized centers that are certified to conduct metagenomic testing.  Metagenomic assays utilize advances in DNA extraction technology, DNA sequence library construction, high throughput DNA sequencing and automated data analysis to identify millions of individual strands of DNA extracted from clinical samples.  At present, metagenomic assays are only possible at a small number of special research, academic and commercial laboratories.  Continued research in human and path

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Nov 01 2009
Journal Name
Iraqi J Comm Med
Clinical Presentations and CT-Scan findings in children with Cerebral Palsy
...Show More Authors

Background: Cerebral palsy is non-progressive disorder of posture or movement due to a lesion of the developing brain. It is the commonest physical disability in childhood. Objective: To study the clinical, neurological abnormalities, prevalence of convulsion (epilepsy) & to asses the value of CT scans of brain in patients with cerebral palsy.

Publication Date
Wed Sep 19 2018
Journal Name
Biomedical And Pharmacology Journal
Influence of Silver Nanoparticles on the Specific Properties of Acrylic Resin for Ocular Prosthesis
...Show More Authors

Scleral acrylic resin is widely used to synthesize ocular prosthesis. However, the properties of this material change over time, thus requiring the prosthesis to be refabricated. Many studies were conducted to improve these properties by reinforcing this material with nanoparticles. This study aims to evaluate the effect of silver nanoparticle powder on the mechanical properties (transverse flexural strength, impact strength, shear bond strength, surface microhardness, and surface roughness) of scleral acrylic resin used for ocular prostheses. Two concentrations were selected from the pilot study and evaluated for their effects on scleral acrylic resin properties. According to the pilot study, 0.01 and 0.02wt% AgNPs powder improved

... Show More
View Publication
Scopus (5)
Crossref (4)
Scopus Crossref
Publication Date
Wed Apr 19 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
The Effect of Al2O3 Additives on Some Mechanical Properties of Un Saturated Polyester Resin
...Show More Authors

   This study included preparation for the unsaturated polyester samples before and after reinforced by the Alumina oxide powder of different volume fraction amounting (2%,4%,6%).    And this research included the study of some of mechanical properties such as (Hardness,compressive,wear).     The results showed that the increase of the hardness and compressive strength after the reinforced and the increase with the volume fraction increase.   As the wear test shows that the wear rate increases with applied load increase(5,10,15) from  (10.6-18.6) gm/cm befor reninforced and from(5.4-15.2)gm/cm,(4.7-12.9)gm/cm,(48.1)gm/cm,after reinforced from the different volume fraction, and t

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Laser
PDF Influence of Er:Cr;YSGG laser Desensitization on SBS of resin cement to dentin
...Show More Authors

Background: Crown preparation of vital teeth involve the removal of a sound tooth structure, and when enamel removed this lead to exposed dentin with an   increase in the number of open dentinal tubules also the diameter of dentinal tubules will increase, furthermore lead to increase movement of fluids inside the tubules all that causes post preparation sensitivity. The aim of this study is to evaluate the effect of desensitizing by Er:Cr:YSGG laser on shear bond strength of prepared tooth and resin cement. Materials and methods: Thirty sound maxillary premolars, grouped into three groups(n=10). Group A is the control group, group B irradiated by Er:Cr:YSGG laser with (0.25 W, 20 Hz, 1

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of Impact and Transverse Strength of Denture Bases Repaired with Nano Reinforced Resin
...Show More Authors

Background: Failure of resin bases were a major disadvantage recorded in the constructed dentures. Reinforcements of the repair joint with nano fillers represent an attempt to enhance the strength and durability. The purpose of the research was to estimate the influence of nano fillers reinforcement with (ZrO2 and Al2O3) on impact and transverse strength of denture bases repaired with either cold or hot processing acrylic resin. Materials and methods: A hundred and forty (140) samples were processed with hot cured resin and organized in subgroups depending on the repair materials and condition (without repair (control), repair with hot cure, cold cure, hot and cold cure reinforced with either (5% Zr2O or 0.5% Al2O3). The samples in these

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2011
Journal Name
Iraqi Journal Of Physics
Dielectric Waveguide for Composite Materials
...Show More Authors

The Maxwell equations have been formulated for a composite slab waveguide at x-band wave propagation. The eigenvalues of the system equations are obtained by using MATLAB program. These eigenvalues are used to obtain the wave propagation constant and a number of modes inside the slabs. A good correspondence was seen between the number of modes and the cut off thickness. The parameter that affects the performance of waveguide is the slab thickness. The propagation constant is usually adopted to characterize this type of waveguide and show how the cutoff frequency of the mode in the slab is increased dramatically by decreasing the frequency.
Our study focused on lower modes, the results for the transmission coefficient are then used to

... Show More
View Publication Preview PDF