Preferred Language
Articles
/
jbcd-3216
12- months color stability of direct resin composite veneers in anterior teeth: Clinical trial
...Show More Authors

Background: This clinical trial aims to evaluate the color changes of direct resin composite veneer (DCV) restorations based on spectrophotometric analysis of 4 different types of resin composites between the baseline immediately after polishing and after one year of follow-up. Materials and methods: 28 patients were assessed for eligibility for participation, aged between 18 and 38 years old, who indicated for DCV restorations in anterior maxillary teeth were considered for participation in this study. In total, 25 patients who met the inclusion criteria were selected (6 males and 19 females, mean age: 20.9 at the time of restoration placement), and 3 patients were excluded. Participants were divided into four groups based on the type of composite resin used for restorations. Group 1 nanohybrid Ips Empress direct (Ivoclar Vivadent)](IPS) (13 restorations/6 patients), group 2 microfilled [Essentia (GC cooperation Japan)](ES) (14 restorations / 7 patients), group 3 supra-nano filled [ Estelite ∑ Quick (Tokuyama, Tokyo, Japan)](EQ) (17 restorations / 7 patients) and group 4 nanofill [Filtek Ultimate (3M ESPE)](FU) (13 restorations / 5 patients). Baseline Color measurements were performed with a spectrophotometer immediately after finishing and polishing (baseline), and after one year of recall, color change (ΔE) from baseline values and after one year of follow-up of DCVs were calculated according to CIELab color coordinates. For this, a silicone mold was fabricated for each patient and used as a guide for each measurement to standardize the site of the readings. Statistical analysis of the data was applied using the Kruskal-Wallis test with Dunn-Bonferroni posthoc test after controlling the distribution of data in terms of normality with the Shapiro Wilk test. Results: At the end of one year,25 participants(57restorations) were followed up. The mean ΔE of IPS, EQ, and FU composites were higher than the ES composite resin, but there was no statically significant difference between all types of composites (P> 0.05). There was no statistically significant difference in the mean ΔL* between any types of composite resin (p> 0.05). There was a significant change in Δa* and Δb* after a one-year recall for all the types of DCV restorations (p < 0.05). Conclusion: After one year of follow-up, the spectrophotometer measurements of direct resin composite veneer restorations, it was concluded no difference between the mean ΔE of ES, IPS, FU, and EQ resin composite. ES (Microfilled hybrid) showed a lower mean ΔE value compared to the other groups. All groups of resin composite showed color changes within clinically acceptable levels after a one-year follow-up.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Nov 19 2018
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Study of the impact of foreign direct investment in the Iraqi tax system using the factorial analysis: (principal components)
...Show More Authors

The tax system, like any other system, as a set of elements and parts that complement each other and are interrelated and interact to achieve specific goals, and is a natural  reflection of the economic, social and political conditions prevailing in society, and therefore the objectives of tax policy formulated in line with the objectives of economic policy in general, which means that any change in economic policy clearly affects fiscal policy measures and fiscal policy in particular.

The problem of searching for the impact of foreign direct investment in the Iraqi tax system was focused on the study  the of foreign direct investment and therole played in developing and improving the economic reality and its implicatio

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Feb 24 2019
Journal Name
Iraqi Journal Of Physics
The effect of triggering on the output performance of diode direct face pumping for disc laser in pulse mode
...Show More Authors

The triggering effect for the face pumping of Nd:YVO4 disc medium of 4×5×0.5 mm was investigated using bulk diode laser at different resonator cavity length in pulse mode and at repetition rate of 1.3kHz. The maximum emitted peak power was found to be 100, 82, and 66 mW for resonator lengths of 10, 13.5, and 17.5 cm respectively, while the threshold pumping power was found to be 41mW. The maximum emitted peak power obtained was 300 mW when using external triggering and 10cm length, with repetition of 3Hz.

View Publication Preview PDF
Crossref
Publication Date
Mon Jun 16 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Enamel defect of primary and permanent teeth in relation to nutrients daily intake among Down's syndrome children in comparison to normal children
...Show More Authors

Background: Any child with Down's syndrome does not develop in the same manner as normal child. Therefore, the child should not be viewed as being like everyone else. Developmental enamel defects in primary teeth have been found at least twice as frequently in disabled children as in control children. Down's syndrome consumed protein more than the recommended daily allowance compared to other disabled groups. Therefore, the aim of this study was to investigate developmental defects of enamel and their relations to nutrient intake among Down's syndrome children in comparison to normal children. Materials and Methods: A sample consisted of fifty institutionalized Down's syndrome children (study group) and 50 normal children (control group)

... Show More
View Publication Preview PDF
Publication Date
Sun Nov 15 2020
Journal Name
​​​​arabian Journal Of Scientific Research
Isolation and characterization of Candida glabrata from clinical specimens in some hospitals in Baghdad
...Show More Authors

This study aimed for isolation and identification of Candida glabrata and identifying some virulence factors. The distribution of patients with candidemia thrush showed that the age group 50-65 years old recorded the highest incidence of candidiasis in female and male with leukemia by 50% and 37.9 % respectively compared to the lowest incidence of candidiasis in the age group under 17 years old in female and male 8.8% and 13.5%, respectively. While the age group between 5-8 years was high, reaching 18 cases of oral candidiasis and 42% of children with leukemia compared with the age group, which was the least, that reached 9 cases, 21%. The highest incidence of C. glabrata was 59 isolates of females and males with leukemia, while C. kefyer w

... Show More
Publication Date
Wed May 01 2019
Journal Name
Solid State Phenomena
Preparation and Study of the Mechanical Properties of Unsaturated Polyester Resin/Graphene Nanocomposite
...Show More Authors

Nanocomposite was prepared using unsaturated polyester (UP) resin as a matrix and graphene nanoparticles as a reinforcement material in six percentage weights (0, 0.1, 0.2, 0.3, 1 and 1.5%). Mechanical, calorimetric and thermal studies were performed on the (UP) resin/graphene nanocomposite. All tests showed a clear improvement of all mechanical properties examined (hardness, flexural strength (F.S), impact strength (I.S) and tensile strength (T.S)) with increasing graphene percentage. In addition, the temperature of glass transition and thermal conductivity of this composite increased with increasing graphene content.

View Publication
Scopus (4)
Crossref (1)
Scopus Crossref
Publication Date
Sat Dec 01 2012
Journal Name
Iraqi Journal Of Physics
The effect of additive carbon nano tube on optical properties of epoxy resin
...Show More Authors

In this work, MWCNT in the epoxy can be prepared at room temperature and thickness (1mm) at different concentration of CNTs powder. Optical properties of multi-walled carbon nanotubes (CNTs) reinforced epoxy have been measured in the range of (300-800)nm. The electronic transition in pure epoxy and CNT/epoxy indicated direct allowed transition. Also, it is found that the energy gap of epoxy is 4.1eV and this value decreased within range of (4.1-3.5)eV when the concentration of CNT powder increased from (0.001-0.1)% respectively.
The optical constants which include (the refractive index (n), the extinction coefficient (k), real (ε1) and imaginarily (ε2) part of dielectric constant calculated in the of (300-800)nm at different concent

... Show More
View Publication Preview PDF
Publication Date
Thu Nov 08 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Effect of using two packing Technic on Hardness of two dental acrylic resin
...Show More Authors

Objective: the aim of this study is to invest age and determine the effect of using (2) packing
technique (conventional and new tension technique) on hardness of (2) types of heat cure acrylic
resin which are (Ivoclar and Qual dental type).
Methodology : this study was intended the using of two types of heat cure acrylic (IVoclar and
Qual dental type) which are used in construction of complete denture which packed in two different
packing technique (conventional and new tension technique) and accomplished by using a total of
(40) specimens in diameter of ( 2mm thickness, 2 cm length and 1 cm width) . This specimens were
sectioned and subdivide into (4) group each (10) specimens for one group , then signed as (A, Al B

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Radiological Evaluation of The Anatomic Characteristic of Lingual Foramina and Their Vascular Canals in The Anterior Region of The Mandible Using Cone Beam Computed Tomography
...Show More Authors

Background: presence of lingual vascular foramina and canals in the interforaminal regionmay increase the risk ofsurgical complications during implant placement or any surgical procedure in this area.Aim of this study is the radiological evaluation of the anatomic characteristic of the lingual foramina and their vascular canals in the anterior of the mandible using cone beam computed tomography. Materials and Methods: Prospective study including 72 Iraqi subjects (31 male and 41 female) ranging from 20 to 59 years, all subjects attended AL- Sharaa dental clinic in AL-Najaf AL-Ashraf city, scanned with CBCT from September 2016 to February 2017. Using 3dimentional and sagittal cross section to detect lingual foramina and their vascular canals

... Show More
View Publication
Crossref
Publication Date
Thu Mar 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Radiological Evaluation of the Anatomic Characteristic of Lingual Foramina and Their Vascular Canals in the Anterior Region of the Mandible Using Cone Beam Computed Tomography
...Show More Authors

Background: presence of lingual vascular foramina and canals in the interforaminal region may increase the risk ofsurgical complications during implant placement or any surgical procedure in this area. Aim of this study is the radiological evaluation of the anatomic characteristic of the lingual foramina and their vascular canals in the anterior of the mandible using cone beam computed tomography. Materials and Methods: Prospective study including 72 Iraqi subjects (31 male and 41 female) ranging from 20 to 59 years, all subjects attended Al-Sharaa dental clinic in AL-Najaf AL-Ashraf city, scanned with CBCT from September 2016 to February 2017. Using 3dimentional and sagittal cross section to detect lingual foramina and their vascular canal

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Sun Feb 24 2019
Journal Name
Iraqi Journal Of Physics
Measuring the concentration of uranium for adults teeth in adjacent areas of Tigris river in Baghdad city using nuclear track detector CR-39
...Show More Authors

In this study, the fission track registration technique with the CR-39 detector are using to determination the uranium concentrations for seventeen samples of teeth distributed in four districts in Baghdad City .Five samples taken from both Al-Durra District and Al-Jadiriyia District, Four samples taken from Al-Karrda (Alaatar street) Taken four samples and three samples taken from Al-Zuafrania and by 0.5gm in weight and 1.5 mm in thickness. The uranium concentrations in teeth samples measured by using fission tracks registration in (CR-39) track detector that caused by the bombardment of (U) with thermal neutrons from (241 Am-Be) neutron source that has flux of (5 ×103 n cm-2 s-1). The concen

... Show More
View Publication Preview PDF
Crossref (1)
Crossref