Background: Recurrent aphthous stomatitis (RAS) is one of the most common oral mucosal disorders with a prevalence of 50-66%. The prevalence of hematinic deficiencies including ferritin and vitamin B12 deficiencies and their role in the prophylaxis and development of RAS is not well known. Many studies have demonstrated a high prevalence of hematinic deficiencies in patients with RAS. This study aimed to compare the serum level of ferritin and vitamin B12 in patients with recurrent aphthous ulcers and healthy controls. Subjects, Materials and Methods: The data were collected from patients who needed blood analysis to exclude anemia from November 2020 to May 2021. The study was approved by the institutional ethics committee. After recording patients' demographics ( age, gender, occupation, address) 5ml of blood was drawn from patients and controls in educational laboratories centrifuged at 3000 rpm for 10 minutes, then serum was stored at -20°C till the time of assessment of both serum ferritin and vitamin B12. The data were expressed as Mean ± SD. Students Unpaired t-test was used for comparing biochemical parameters between patients and controls and a p-value of <0.05 was considered as a statistically significant while a p-value of<0.001 was considered highly statistically significant. Results: A total of 30 RAS patients and 30 healthy control with age and gender matches were included. In the present study statistically, significant differences were observed in the serum level of ferritin and vitamin B12 between the two groups, 40% of the patients had low serum ferritin levels and 56.6 % of the patients had low serum vitamin B12 levels. Conclusion: Measuring serum ferritin and vitamin B12 levels are necessary for patients with recurrent aphthous stomatitis. It is also important for recurrent aphthous ulcer patients to have a nutritional diet containing iron and vitamin B12 to prevent the recurrence of aphthous ulceration
Photonic Crystal Fiber Interferometers (PCFIs) are widely used for sensing applications. This work presents the fabrication and study the characterization of a relative humidity sensor based on a polymer-infiltrated photonic crystal fiber that operates in a Mach- Zehnder Interferometer (MZI) reflection mode. The fabrication of the sensor only involves splicing and cleaving Photonic Crystal Fiber (PCF) with Single Mode Fiber (SMF). A stub of (LMA-10) PCF spliced to SMF (Corning-28). In the splice regions. The PCFI sensor operation based on the adsorption and desorption of water vapour at the silica-air interface within the PCF. The sensor shows a high sensitivity to RH variations from (27% RH - 95% RH), with a change in its reflected powe
... Show MoreVisible-light photodetectors constructed Fe2O3 were manufactured effectively concluded chemical precipitation technique, films deposited on glass substrate and Si wafer below diverse dopant (0,2,4,6)% of Cl, enhancement in intensity with X-ray diffraction analysis was showed through favored orientation along the (110) plane, the optical measurement presented direct allowed with reduced band gap energies thru variation doping ratio , current–voltage characteristics Fe2O3 /p-Si heterojunction revealed respectable correcting performance in dark, amplified by way of intensity of incident light, moreover good photodetector properties with enhancement in responsivity occurred at wavelength between 400 nm and 470 nm.
<p>The polyacrylonitrile (PAN)/polysulfone (PSF) blended polymer membranes were modified by decaethylene glycol monododecyl ether (C<sub>12</sub>EO<sub>10</sub>) as a non-ionic surfactant. Polymeric solutions containing 17 wt.% of both PAN and PSF with a ratio of 80/20, and C<sub>12</sub>EO<sub>10</sub> with a mass concentration of 6 wt.% and aluminium oxide (Al<sub>2</sub>O<sub>3</sub>) nanoparticles with varying concentrations (1, 2, and 3 wt.%) were prepared. Adding 6 wt.% of C<sub>12</sub>EO<sub>10</sub> to the casting solution formed a membrane with distinguished hydrophilicity and fouling resistance, higher porosity, appreciable pe
... Show MorePharmaceuticals have been widely remaining contaminants in wastewater, and diclofenac is the most common pharmaceutical pollutant. Therefore, the removal of diclofenac from aqueous solutions using activated carbon produced by pyrocarbonic acid and microwaves was investigated in this research. Apricot seed powder and pyrophosphoric acid (45 wt%) were selected as raw material and activator respectively, and microwave irradiation technique was used to prepare the activated carbon. The raw material was impregnated in pyrophosphoric acid at 80◦C with an impregnation ratio of 1: 3 (apricot seeds to phosphoric acid), the impregnation time was 4 h, whereas the power of the microwave was 700 watts with a radiation time of 20 min. A series o
... Show Moreتضمن هذا العمل تحضير ليكند قاعدة شيف جديدة مشتقة من مادة البولي أكريلاميد والكلوترالديهايد [(2S, 2'S) – N, N' - (pentane-1, 5-diylidene) bis (2- methylbutan amide)] مع بعض المعادن الثقيلة (Cr + 3 Mn + 3 , Fe + 3 , ,Co + 2, Ni + 2 ,Cu + 2 Zn + 2 , Cd + 2,) لتنتج المعقدات المقابلة. تم تشخيص قواعد شيف ومعقداتها المعدنية بأستخدام طيف الأشعة تحت الحمراء والأشعة المرئية وفوق البنفسجية، والتوصيلية ,وقيم المغناطيسية والتحليل الحراري الوزني وحيود الأشعة السينية ومجه
... Show MoreSpectrophotometric method was developed for the determination of copper(II) ion. Synthesized (2,2[O-Tolidine-4,4-bis azo]bis[4,5-diphenyl imidazole]) (MBBAI) was used as chromogenic reagent at pH=5. Various factors affecting complex formation, such as, pH effect, reagent concentration, time effect and temperature effect, have been considered and studied. Under optimum conditions concentration ranged from (5.00-80.00) µg/mL of copper(II) obeyed Beer`s Low. Maximum absorption of the complex was 409nm with molar absorpitivity 0.127x104 L mol-1 cm-1. Limit of detection(LOD) and Limit of quantification were 1.924 and 6.42 μg/mL, respectively.
... Show MoreThis study examines the removal of ciprofloxacin in an aqueous solution using green tea silver nanoparticles (Ag-NPs). The synthesized Ag-NPs have been classified by the different techniques of SEM, AFM, BET, FTIR, and Zeta potential. Spherical nanoparticles with average sizes of 32 nm and a surface area of 1.2387m2/g are found to be silver nanoparticles. The results showed that the ciprofloxacin removal efficiency depends on the initial pH (2.5-10), CIP (2-15 mg/L), temperature (20-50°C), time (0-180 min), and Ag-NPs dosage (0.1-1g/L). Batch experiments revealed that the removal rate with ratio (1:1) (w/w) were 52%, and 79.8% of the 10 mg/L of CIP at 60, and 180 minutes, respectively with optimal pH=4. Kinetic models for adsorpti
... Show More
