Preferred Language
Articles
/
jbcd-315
Diagnosis and localization of the maxillary impacted canines by using dental multi-slice computed tomography 3D view and reconstructed panoramic 2D view
...Show More Authors

Background: Diagnosis and treatment planning can be difficult with conventional radiographic methods as the orthodontic-surgical management of impacted canines requires accurate diagnosis and precise localization of the impacted canine and the surrounding structures. This study was aimed to localize and evaluate weather there is any differences in the diagnostic information provided by multi-slice computed tomography three dimensional volumetric CT images and two dimensional reconstructed panorama images (derived from CT) in subjects with impacted maxillary canines. Materials and Methods: Thirty patients including 24 female and 6 male with mean age of 18 years with suspected unilaterally or bilaterally impacted maxillary canines were evaluated on images taken with Brilliance™ 64, Philips multi-detector computed tomography. The spatial relationships of the impacted maxillary canines relative to the adjacent structures was evaluated using linear and angular measurements, and the adjacent lateral incisor root resorption was assessed with three dimensional and two dimensional visualization software. Results: The inclination of the impacted maxillary canine measured to the midline and to the occlusal plane did not differ significantly when it was evaluated using the two imaging modalities. However, there were significant differences between the 3D and 2D images with respect to the impacted maxillary canine vertical height, bucco-palatal localization, and in detecting the proximity and root resorption of the adjacent lateral incisors. Conclusion: Dental CT volumetric images provide more reliable and accurate information for diagnosing the maxillary impacted canine position, inclination, distance from adjacent structures, and detection of lateral incisors rootresorption.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Dec 04 2021
Journal Name
Ournal Of Global Trends In Pharmaceutical Sciences
REVIEW ARTICLE: COVID – 19: INFECTION, ORIGIN, TRANSMISSION, DIAGNOSIS, TESTS AND TREATMENT OPTIONS
...Show More Authors

Publication Date
Tue Feb 06 2018
Journal Name
International Journal Of Gynecology And Obstetrics
FIGO consensus guidelines on placenta accreta spectrum disorders: Prenatal diagnosis and screening
...Show More Authors

Recent population studies have shown that placenta accreta spectrum (PAS) disorders remain undiagnosed before delivery in half to two-thirds of cases. In a series from specialist diagnostic units in the USA, around one-third of cases of PAS disorders were not diagnosed during pregnancy. Maternal

View Publication Preview PDF
Scopus (271)
Scopus
Publication Date
Sun Jun 01 2025
Journal Name
Journal Of University Of Anbar For Pure Science
SARS-CoV-2 history, diagnosis, genetic diversity and treatment: a comprehensive review
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of Research In Medical And Dental Science
Evaluation of the Serum Level of Interleukin-6 in Patients Undergoing Surgical Removal of Impacted Mandibular Third Molars
...Show More Authors

Evaluation of the Serum Level of Interleukin-6 in Patients Undergoing Surgical Removal of Impacted Mandibular Third Molars, Hussain A Taher*, Salwan Y Bede

View Publication Preview PDF
Publication Date
Tue Sep 01 2020
Journal Name
Iraqi Journal Of Physics
The magnetic switch manufacturing by using ferrofluid and ferrofluid doped copper nanoparticles
...Show More Authors

In this work, a magnetic switch was prepared using two typesof ferrofluid materials, the pure ferrofluid and ferrofluid doped with copper nanoparticles (10 nm). The critical magnetic field (Hc) and the state of magnetic saturation (Hs) were studied using three types of laser sources. The main parameters of the magnetic switch measured using pure ferrofluid and He-Ne Laser source were Hc(0.5 mv, 0.4 G), Hs (8.5 mv, 3 G). For the ferrofluid doped with copper nanoparticles were Hc (1 mv, 4 G), Hs (15 mv, 9.6 G), Using green semiconductor laser for the Pure ferrofluid were Hc (0.5 mv, 0.3 G) Hs (15 mv, 2.9 G). While the ferrofluid doped with copper nanoparticles were Hc (0.5 mv, 1 G), Hs (12 mv, 2.8 G) and by using the violet semiconductor l

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 30 2015
Journal Name
Al-khwarizmi Engineering Journal
Multi-Focus Image Fusion Based on Pixel Significance Using Counterlet Transform
...Show More Authors

Abstract

 The objective of image fusion is to merge multiple sources of images together in such a way that the final representation contains higher amount of useful information than any input one.. In this paper, a weighted average fusion method is proposed. It depends on using weights that are extracted from source images using counterlet transform. The extraction method is done by making the approximated transformed coefficients equal to zero, then taking the inverse counterlet transform to get the details of the images to be fused. The performance of the proposed algorithm has been verified on several grey scale and color test  images, and compared with some present methods.

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 01 2023
Journal Name
Indonesian Journal Of Electrical Engineering And Computer Science
Image encryption based on combined between linear feedback shift registers and 3D chaotic maps
...Show More Authors

Protecting information sent through insecure internet channels is a significant challenge facing researchers. In this paper, we present a novel method for image data encryption that combines chaotic maps with linear feedback shift registers in two stages. In the first stage, the image is divided into two parts. Then, the locations of the pixels of each part are redistributed through the random numbers key, which is generated using linear feedback shift registers. The second stage includes segmenting the image into the three primary colors red, green, and blue (RGB); then, the data for each color is encrypted through one of three keys that are generated using three-dimensional chaotic maps. Many statistical tests (entropy, peak signa

... Show More
View Publication
Scopus (6)
Crossref (5)
Scopus Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Solution of Nonlinear High Order Multi-Point Boundary Value Problems By Semi-Analytic Technique
...Show More Authors

In this paper, we present new algorithm for the solution of the nonlinear high order multi-point boundary value problem with suitable multi boundary conditions. The algorithm is based on the semi-analytic technique and the solutions are calculated in the form of a rapid convergent series. It is observed that the method gives more realistic series solution that converges very rapidly in physical problems. Illustrative examples are provided to demonstrate the efficiency and simplicity of the proposed method in solving this type of multi- point boundary value problems.

View Publication Preview PDF
Crossref
Publication Date
Thu Apr 18 2013
Journal Name
International Journal Of Computer Applications
Design and Simulation of Hartley based Multi Orthogonal Band OFDM
...Show More Authors

Recent advances in wireless communication systems have made use of OFDM technique to achieve high data rate transmission. The sensitivity to frequency offset between the carrier frequencies of the transmitter and the receiver is one of the major problems in OFDM systems. This frequency offset introduces inter-carrier interference in the OFDM symbol and then the BER performance reduced. In this paper a Multi-Orthogonal-Band MOB-OFDM system based on the Discrete Hartley Transform (DHT) is proposed to improve the BER performance. The OFDM spectrum is divided into equal sub-bands and the data is divided between these bands to form a local OFDM symbol in each sub-band using DHT. The global OFDM symbol is formed from all sub-bands together using

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Jul 15 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Digital panoramic estimation of chronological age among Iraqi adult population in relation to morphological variables of canine teeth
...Show More Authors

Background: Age determination of skeletal remains is apart of many medico-legal as well as anthropological examination. Many anatomical structures have been studied, but the teeth and their measurements seem to be the most reliable method since teeth represent the most durable and resilient part of the skeleton. This study was undertaken for estimating the chronological age among Iraqi adult subjects based on various morphological variables of canine teeth using digital panoramic radiograph. Material and methods: The sample in the current study consisted of 240 Iraqi patients attending to the dental radiological clinic at College of dentistry/ Babylon University taking panoramic radiographs for different diagnostic purposes, the study samp

... Show More
View Publication Preview PDF