Preferred Language
Articles
/
jbcd-3141
Effect of Optiglaze Coating on the Staphylococcus aurous and Porosity of Heat Cured Acrylic Material
...Show More Authors

Background: Polishing technique for acrylic resin material have great effect on properties of acrylic material and bacterial colonization such as staphylococcus aurous, which are responsible for many acrylic prosthetic infections such as the commonly ocular infections. Ineffective polishing technique could affect roughness and subsequently porosity of acrylic materials.So, a new effective method for polishing acrylic was used depending on the use of optiglaze coating material. So, this study aimed to evaluate the effect of optiglaze polishing on porosity of acrylic resin material and staphylococcus aurous activity in comparison to conventional polishing technique. 

Materials and methods: Specimen(n=120) were prepared :20 specimens constructed as circle shaped diameter 30mm with 1 mm thickness for porosity  test (10 control polishing by conventional technique and 10 polishing by optiglaze technique). Other 82 specimens were prepared as circle specimen (6mm diameter and 1mm thickness) for sensitivity and adherences test ( each test have 20 specimens10 control and 10 optiglaze) and 42 specimens for viability test for three dilution,21 specimens for control and 21 for optiglaze (7 specimens for each dilution). Porosity were tested by light microscopic while agar well technique, adherence test and viability count test were tested for antibacterial activity of optiglaze against staphylococcus aurous.

Result: The high mean value for porosity test was recorded by control while low mean value was recorded by optiglaze group with significant differences between them. Sensitivity and adherence test high mean value recorded by optiglaze with highly significant differences in comparison to control. Viability count test all dilution 10-7 ,10-6, 10-5 showed highly significant reduction in viability count of staphylococcus aurous by optiglaze group in comparison to control. Conclusion Polishing technique by Optiglaze significantly decrease porosity of acrylic resin and this method inhibited growth of staphylococcus aurous, and decrease its viable count (have antibacterial effect) but had less effect in adherence of this bacterial in comparison to control.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of International Society Of Preventive And Community Dentistry
Investigating tensile bonding and other properties of yttrium oxide nanoparticles impregnated heat-cured soft-denture lining composite in vitro
...Show More Authors

Aims: This study was conducted to assess the effect of the addition of yttrium oxide (Y2O3) nanoparticles on the tensile bond strength, tear strength, shore A hardness, and surface roughness of soft-denture lining material. Materials and Methods: Y2O3 NPs with 1.5 and 2 wt.% were added into acrylic-based heat-cured soft-denture liner. A total of 120 specimens were prepared and divided into four groups according to the test to be performed (tensile bond strength, tear strength, surface hardness, and surface roughness). Results: There was a highly significant increase in tensile bond strength between the soft liner and the acrylic denture base, tear strength, and hardness at both concentrations as compared to the control group, whereas ther

... Show More
View Publication
Scopus (14)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Mon Dec 31 2018
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
STUDYING THE EFFECT OF Proteinase K AND α-Amylase ON INHIBITION OF Staphylococcus aureus AND Klebsiella pneumoniae BIOFILM ISOLATE FROM URINARY TRACT INFECTION.: STUDYING THE EFFECT OF Proteinase K AND α-Amylase ON INHIBITION OF Staphylococcus aureus AND Klebsiella pneumoniae BIOFILM ISOLATE FROM URINARY TRACT INFECTION.
...Show More Authors

The current study aimed to investigate the viability of biofilm formation klebsilla pneumoniae and Staphylococcus aureus. 440 urine samples were collected from patients suffering from urinary tract infection (UTI) from those who were admitted and visitors to Al-Ramadi Teaching Hospital, Al-Yarmouk Teaching Hospital, Al-Ramadi Teaching Hospital for women and children and , Teaching Laboratories in the Medical City for both genders for a period extended from 5 July, 2017 to 10 October, 2017. Samples were diagnosed by culturing them on a selective media and by biochemical testes , also, diagnosis was ensured by using VITEK-2 compact system. Results showed that K.pneumoniae isolation ratio was 17.1%(68) and S.aureus ratio was 13.1%(52). Thei

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
Technologies And Materials For Renewable Energy, Environment, And Sustainability: Tmrees23fr
The effect between combination of cold plasma and gold nano material on blood components
...Show More Authors

A simple low-cost approach at various exposure times was utilized to generate cold plasma in the aim to fabricate AuNPs. UV-Visible spectra and X-ray diffraction were used to characterize the nanoparticles (XRD). Surface Plasmon resonance was observed in the synthesized AuNPs at 530, 540, and 533 nm. For all samples, the patterns of XRD show very intensive peaks implying the fcc crystalline structure of AuNPs. The average crystallite size of AuNPs is ranging between 20-30 nm. The observation of morphology by FESEM revealed the spherical formation of AuNPs. Doses of 100 and 200 ppm of AuNPs were adapted to investigate their effect on the blood-mixture with and without a 20-second of cold plasma exposure. The WBC components in the blood

... Show More
View Publication
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Biochemical And Cellular Archives
EFFECT OF CHALCONE ON THE FORMATION OF BIOFILMS AND EXPRESSION OF VIRULENCE GENES IN METHICILLIN-RESISTANT STAPHYLOCOCCUS AUREUS
...Show More Authors

MRSA is one of the major pathogens in hospitals and the community, which have the ability to produce biofilm as a virulence factor, the impact of chalcone on biofilm formation, the synergism effect of chalcone and antibiotic in both in vitro and in vivo experiments, the gene expression of virulence genes (srtA, fnbA, fnbB) before and after treatment of it on MRSA biofilm cells in vitro, all these were the prime aims of this study. Chalcone at MBIC (20 μg/ml), significantly reduced the biofilm formation to 21.45% and at sub MBIC (15 μg/ml) to 36.58 %. While, Chalcone at MIC(5 μg/ml) reduced MRSA planktonic cells to 49.61%. Susceptibility of MRSA isolates against eight antibiotics showed that all isolates were sensitive to vancomycin and n

... Show More
Preview PDF
Scopus (1)
Scopus
Publication Date
Sun Sep 04 2011
Journal Name
Baghdad Science Journal
Effect of Lactobacilli sources on Escherichia coli and Staphylococcus aureus adherence to uroepithelial cells
...Show More Authors

The inhibitory action of four lactobacilli isolates Lactobacillus bulgaricus, L. acidophilus, L. plantarum and L. fermentum, isolated from four different samples; yoghurt, vinegar, saliva and vagina respectively, on Escherichia coli and Staphylococcus aureus adhesion to uroepithelial cells were investigated. Results showed that all Lactobacillus isolates or their supernatant were able to reduce the number of the uropathogens attached to uroepithelial cells. However, inhibition level of lactobacilli cells was higher than their supernatant. Nevertheless, the human indigenous lactobacilli (L. fermentum and L. plantarum) were more competitive than food lactobacilli (L. acidophilus and L. bulgaricus).

View Publication Preview PDF
Crossref
Publication Date
Sun Jun 11 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
The Effect of Different Thermal Treatments on Corrosion Behavior of the Hydroxyapatite Coated on Ti-6Al-4V Alloy by Electrophoretic Deposition and Dip Coating
...Show More Authors

    In this research, the study of thermal treating by laser, plasma glow discharge and tubular furnace on Ti-6Al-4V alloy coated with hydroxyapatite by methods of dip coating and electrophoretic deposition .A group of samples was coated by dip coating and another group was coated by electrophoretic deposition. The first group was treated by pulse laser 10 (mJ) as energy for samples from both coating with uniform distributed pulses on every single sample surface, The second thermal treating was made by plasma glow discharge in a locally made system with argon atmosphere, 600 Volt , and 6 cm distance between the electrodes, The third treating was made by tubular furnace in air atmosphere and 400 °C for 1 hour duration. T

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Apr 30 2017
Journal Name
Journal Of Engineering
The Effect of Fin Design on Thermal Performance of Heat Sink
...Show More Authors

      An experimental and computational study is conducted to analyze the thermal performance of heat sinks and to pick up more profound information in this imperative field in the electronic cooling. One important approach to improve the heat transfer on the air-side of the heat exchanger is to adjust the fin geometry. Experiments are conducted to explore the impact of the changing of diverse operational and geometrical parameters on the heat sink thermal
performance. The working fluid used is air. Operational parameters includes: air Reynolds number (from 23597 to 3848.9) and heat flux (from 3954 to 38357 W/m
2 ). Conformational parameters includes: change the direction of air flow and the area of conduct

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
The Effect of Heat Treatment on the Magnetic and Mechanical properties offe - Ni alloys.
...Show More Authors

The aim of this work is studying the binary system ??'??? Ni?)with two ratios (y=36,80) by using casting method for preparing the samples.Magnetic and Mechanical properties have been studidt different httrea^nttem^rature.All the alloys were found a ferromagnetic behavior and sensitive to the heat treatment. Best properties were found at the heat treatment 1100 C°.A significant different results were found above 1100C° for lower magnetic and mechanical values. This is possibly due to the change on the degree of magnetic moment orders, in which most of the moments are started to remove from coupled ferromagnetically.?

View Publication Preview PDF
Publication Date
Sun Apr 08 2018
Journal Name
Al-khwarizmi Engineering Journal
Experimental Investigation of the Effect of Curvature Ratio on Heat Transfer in Double Pipe Helical Heat Exchanger
...Show More Authors

Different parameters of double pipe helical coil were investigation experimentally. Four coils were used; three with a curvature ratio (0.037, 0.031, and 0.028) and 11mm diameter of the inner tube while the fourth with 0.033 curvature ratio and 13 mm diameter of the inner tube. The hot water flow in the inner tube whereas the cold water flows in the annulus. The inlet temperatures of hot and cold water are 50 0C and 18 0C respectively. The inner mass flow rate ranges from 0.0167 to 0.0583 kg/s. The results show the Nusselt number increase with increase curvature ratio. The Nusselt number of the coil with 0.037 curvature ratio increases by approximately 12.3 % as compare with 0.028 curvature ratio. The results also r

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 06 2015
Journal Name
Baghdad Science Journal
The Effect of The Electrochemical Deposition Potential Variation on The Coating of Hydroxyatite on Commertialy pure Titanium (CpTi) and Ti-6Al-4V Alloy
...Show More Authors

In this research we investigated the corrosion behavior of the commertialy pure titanium and Ti-6Al-4V alloy that coated with hydroxyapatite by electrochemical deposition with applied voltage (6,9,12) Volt from aqueous solution containing Ca(NO3)2.H2O =7.0 gm/l , (NH4)2HPO4 =3.5 gm/l , Na(NO3)2 = 8.5 gm/l in order to improve the bonding strength of hydroxyapetite and medical metals and alloys and increasing the biocompatibility. The coating layer morphology was investigated by XRD, Optical microscope , and SEM tests, the corrosio tests was made by use senthesys simulated body fluid (SBF) , and we found that the propreate voltage for coatint on Ti was 9 Volt and for Ti-6Al-4Vwas12Volt.

View Publication Preview PDF
Crossref