Background: Gingival crevice fluid (GCF) is a mixture of substances derived from serum, leukocytes, and structural cells of periodontium and oral bacteria. These substances possess a great potential for serving as indicators of periodontal disease and healing after therapy the main purpose of this study was to find if there is a difference in albumin concentration between healthy and diseased periodontal tissues and to compare between diseased group according to pocket depth Materials and methods: total sample composed of 60 pockets found in 35 patients all of them had no history of any systemic disease, The samples were divided in to three main group that include two diseased groups divided according to the depth of the periodontal pocket (group I were the pocket depth less than 6mm and group II were the pocket depth is equal or more than 6mm) and one healthy group (group III). Sampling of GCF were taken from patients in the second visits of periodontal treatment A previously weighed strips of filter paper size 30 were gently inserted in to the selected pocket depth until resistance was felt the filter paper left in place for 30 seconds and after removal they were weighed on a chemical balance. The difference between the weights of filter paper before and after absorption of exudates was calculated and each filter strips was placed in a tube containing o.3ml of normal saline then transferred and stored at -20C.on the day of analysis the samples were centrifuged at 10.000rpm for 20 minutes .the supernatant was used for assessment of Albunim colorimetrically similar to that of blood. Results: Comparison for gingival fluid weight were shown a non significant difference in the weight between group I&II at a P values >0.05 while there were a highly significant difference between group I&III and between group II&III at P values 0.05 intra groups correlation between albumin content in gingival fluid and periodontal parameter there were a significant negative correlation between plaque index and albumin in group I and II while anon significant correlation in group III also a significant and highly significant correlation were found between albumin and weight of gingival fluid in group I and II while anon significant differences in group III as shown in the table while there were anon significant differences between albumin content of gingival fluid and the gingival index, probing pocket depth and clinical attachment loss. Conclusion: the gingival crevicular fluid is an aqueous component in which is true trasudate and inflammatory exudates after the initial periodontal treatment in which it increased in weight as the inflammation present but the concentration of albumin may became a no significantly different compared with clinically healthy gingiva. As the initial periodontal treatment took place for each patients.
In this paper, some estimators of the unknown shape parameter and reliability function of Basic Gompertz distribution (BGD) have been obtained, such as MLE, UMVUE, and MINMSE, in addition to estimating Bayesian estimators under Scale invariant squared error loss function assuming informative prior represented by Gamma distribution and non-informative prior by using Jefferys prior. Using Monte Carlo simulation method, these estimators of the shape parameter and R(t), have been compared based on mean squared errors and integrated mean squared, respectively
This study investigates the implementation of Taguchi design in the estimation of minimum corrosion rate of mild-steel in cooling tower that uses saline solution of different concentration. The experiments were set on the basis of Taguchi’s L16 orthogonal array. The runs were carried out under different condition such as inlet concentration of saline solution, temperature, and flowrate. The Signal-to- Noise ratio and ANOVA analysis were used to define the impact of cooling tower working conditions on the corrosion rate. A regression had been modelled and optimized to identify the optimum level for the working parameters that had been founded to be 13%NaCl, 35ᴼC, and 1 l/min. Also a confirmation run to establish the p
... Show MoreThis study introduces a highly sensitive trapezium-shaped PCF based on an SPR refractometric sensor with unique design features. The structure of a sensor was designed and analyzed using COMSOL Multiphysics v5.6 based on Finite Element Method (FEM) with a focus on investigating the influence of various geometric parameters on its performance. The two channels were coated with a metallic gold layer to provide chemical stability, and a thin layer of TiO₂ improved the gold's adhesion to the fiber. The findings indicate that the proposed sensor achieves maximum amplitude and wavelength sensitivities of 1,779 RIU⁻¹ and 30,500 nm/RIU, respectively, with corresponding resolutions of 3.2
In this work, synthesis of conducting polymeric films namely, PVC thin films was carried out containing Schiff base (L) with Cu2+, Cr3+, Ni2+, Co2+, in addition to inspecting the possibilities of measuring energy gap values of PVC-L-M with variety metal ions. These new polymeric films (PVC-L-M) were characterized by FTIR spectrophotometry, energy gap and surface morphology. The optical data recorded that the band gap values are influenced by the type of metals. All modified films have a red shift in optical properties in the ultraviolet region. The PVC-L-Co(II) was the lowest value of the optical band gap, 3.1 eV.
Introduction: Carrier-based gutta-percha is an effective method of root canal obturation creating a 3-dimensional filling; however, retrieval of the plastic carrier is relatively difficult, particularly with smaller sizes. The purpose of this study was to develop composite carriers consisting of polyethylene (PE), hydroxyapatite (HA), and strontium oxide (SrO) for carrier-based root canal obturation. Methods: Composite fibers of HA, PE, and SrO were fabricated in the shape of a carrier for delivering gutta-percha (GP) using a melt-extrusion process. The fibers were characterized using infrared spectroscopy and the thermal properties determined using differential scanning calorimetry. The elastic modulus and tensile strength tests were dete
... Show MoreAbstract
Objective(s): The study aims to measure the effectiveness of the program on removing dead tissue for burn patients by testing the nurses before the program in addition to testing them again after implementing the educational program.
Methodology: The study is quantitative in nature (one experimental) and will employ pre- and post-testing techniques between October 17, 2020 and March 20, 2022. A non-probability (purposive) sample of 24 nurses working in the Azadi Teaching Hospital's Burns and Plastic Surgery Center was chosen. The experimental survey of nursing practice, a literature review, scientific records, and previous research were all taken into considerat
... Show MoreAbstract :H.pylori is an important cause of gastric duodenal disease, including gastric ulcers, Mucosa-associated lymphoid tissue (MALT), and gastric carcinoma. biosensors are becoming the most extensively studied discipline because the easy, rapid, low-cost, highly sensitive, and highly selective biosensors contribute to advances in next-generation medicines such as individualized medicine and ultrasensitive point-of-care detection of markers for diseases. Five of ten patients diagnosed with H.pylori ranging in age from 15–85 participated in this research. who [gastritis, duodenitis, duodenal ulcer (DU), and peptic ulcer (PU)] Suspected H.pylori colonies w
... Show MoreNear-ideal p-CdS/n-Si heterojunction band edge lineup has been investigated for the first time with aid of I-V and C-V measurements. The heterojunction was manufactured by deposition of CdS films prepared by chemical spray pyrolysis technique (CSP) on monocrystalline n-type silicon. The experimental data of the conduction band offset Ec and valence band offset Ec were compared with theoretical values. The band offset Ec=530meV and Ev=770meV obtained at 300K. The energy band diagram of p-CdS/n-Si HJ was constructed. C-V measurements depict that the junction was an abrupt type and the built-in voltage was determined from C-2-V plot