Preferred Language
Articles
/
jbcd-3089
The relationship of implant stability quotient and insertion torque in dental implant stability
...Show More Authors

Background: The insertion torque (IT) values and implant stability quotient (ISQ) values are the measurements most used to assess primary implant stability. This study aimed to assess the relationship between ISQ values and IT. Materials and methods: This study included 24 patients with a mean (SD) age of 47.9 (13.64) years (range 25-75 years). The patients received 42 dental implants (DI), 33 in the mandible and 9 in the maxilla. The DI were installed using the motorized method with 35 Ncm torque, When DI could not be inserted to the requisite depth by the motorized method, a hand ratchet was used and the IT was recorded as ˃ 35 Ncm. Implant stability was measured utilizing Osstell® ISQ. The secondary stability was measured after 16 weeks postoperatively.Results: The DI installed in mandible demonstrated significantly higher primary stability ISQ values than those installed in maxilla (P=0.0101). There was no such significant correlation linked between the secondary stability and the recipient jaw (P=0.2026). A non-significant correlation was found between the primary and secondary implant stability ISQ values and IT (P=0.2785 and 0.4194, respectively). No significant difference was reported regarding the IT relative to the recipient jaw of DI (P=0.1349).Conclusion: This study demonstrated that there was no relationship between the ISQ values and the IT, and that they should be used independently. DI installed in mandible demonstrated significantly higher primary stability ISQ values than those installed in maxilla. Also, there was a non-significant correlation of the secondary stability and IT with the recipient jaw.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jan 17 2023
Journal Name
Karbala International Journal Of Modern Science
Biofunctionalization of polyetheretherketone implant material by bone-forming peptide-2 immobilization
...Show More Authors

Polyetheretherketone (PEEK) has favorable biomechanical properties to be used as an implant material. Unfortunately, it is hydrophobic and does not promote cellular adhesion, which could result in poor integration with bone tissue. Bio-functionalization of PEEK surface with osteogenic peptides derived from bone extracellular matrix proteins is an exciting approach to encourage bone formation around the implant. In the current study, bone-forming peptide-2 was immobilized on PEEK surface using two different methods, using dopamine and a diglycidyl ether as conjugate compounds, respectively. Peptide quantification test revealed that the two strategies resulted in the most amount of peptides were attached with 0.5 mM concentration and no furth

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (5)
Scopus Crossref
Publication Date
Fri Jan 01 2016
Journal Name
International Journal Of Advanced Research
ON STABILITY AND THE BOUNDEDNESS OF THE ZERO SOLUTION OF FIFTH ORDER
...Show More Authors

This paper is illustrates the sufficient conditions of the uniformly asymptotically stable and the bounded of the zero solution of fifth order nonlinear differential equation with a variable delay τ(t)

Publication Date
Sun Apr 01 2018
Journal Name
Journal Of Educational And Psychological Researches
Patient Satisfaction and its Relationship to Dental anxiety among patients of Dental Clinics in Baghdad city
...Show More Authors

Patient satisfaction and dental anxiety considered as an important factors in dental health care and treatment because they greatly affect the patient's cooperation with the dentist and the extent to which follows the guidelines, treatment and preventive instruction. The present study investigates the relationship between patient satisfaction and dental anxiety, as well as their relation to demographic variables such as gender, age, number of visits, and cultural level. The study was applied on a random sample of dental clinics in Baghdad city with total of (200) patient (108 male and 92 female). Two scales were used in this study, patient satisfaction scale PSS (included 9 aspects, constructed by authors) and Iraqi dental anxiety scale

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 14 2003
Journal Name
Journal Of Engineering
Slope Stability of Embankments by the Finite Element Method
...Show More Authors

Publication Date
Fri Mar 28 2003
Journal Name
Journal Of Engineering
STABILITY OF UNREINFORCED AND REINFORCED EMBANKMENTS ON SOFT SOILS
...Show More Authors

Publication Date
Mon Dec 05 2022
Journal Name
F1000research
Enhancement of surface properties of polyetheretherketone implant material by fractional laser texturing
...Show More Authors

Background: Polyetheretherketone (PEEK) is a promising implant material due to its superior biomechanical strength. However, due to its hydrophobic nature and lack of cellular adhesion properties, it has poor integration with bone tissue. Methods: A fractional CO2 laser was used with various parameters for surface texturing of PEEK substrate to enhance its surface properties. An optical microscope and field-emission scanning electron microscope (FESEM) were used to examine the surface morphology of untextured and laser-textured samples. Energy dispersive X-ray spectroscopy (EDX) was performed to determine the effect of the laser on the microstructure of PEEK. Surface microroughness, atomic force microscopy (AFM), and wettability were invest

... Show More
View Publication Preview PDF
Crossref (4)
Scopus Crossref
Publication Date
Thu Feb 28 2019
Journal Name
Journal Of Engineering
Asphaltene Stability of Some Iraqi Dead Crude oils
...Show More Authors

Asphaltene is one of the fractions of the crude oil which is soluble in aromatics such as benzene or toluene and insoluble in alkane such as n-heptane, n-pentane or petroleum ether (mixture of alkane compounds).  Asphaltene precipitation is one of the most common problems that sometimes occurs in both oil recovery and refinery processes as a result of changing in pressure, oil composition, or temperature. Therefore the stability of asphaltene in the crude oil must be studied to show the tendency of it for precipitating asphaltene to prevent it (Asphaltene precipitation and deposition problem) and eliminate the burden of high treatment costs.

In the present study, saturate, aromatic, resin and asphaltene (SAR

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Apr 30 2020
Journal Name
Journal Of Economics And Administrative Sciences
Econometrics of the impact of financial inclusion on banking stability in Iraq
...Show More Authors

        Financial inclusion refers to the access of financial services at low cost and high-quality from the formal financial sector to all segments of society, especially marginalized groups, and then use and benefit from them. Financial inclusion is also associated with banking stability, as well as with financial integrity and financial protection for the consumer, therefore, it achieves a number of objectives, the most important of which is to support and enhance banking stability. This is what made it attract the attention of many countries and central banks recently.

     The study aims to show the impact of financial inclusion indicators on ban

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Physical and Histological Evaluation of Coated Implant with Nano ZrO2 after Creation Titania Nanotubes
...Show More Authors

Background: Contact between implant material and bones must be strong and fast creation, to fulfill these properties appropriate surface modifications must apply on used implants. In this contribution; double surface modifications are applied on Ti-6Al-4V alloy to accelerate osseointegration. Materials and methods: Anodic process is utilized to create titania nanotubes (TNTs) on the screws made from Ti-6Al-4V alloy. These implants were coated with nano ZrO2 particles. Second modification was annealing anodized screws at 8000C, and implanted in tibiae of nine adult New Zealand white rabbits. Results: Physical and histological consequences of two surface modifications on Ti-6Al-4V alloy screws were studied. Scanning electron microscope (SEM)

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Mar 31 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Effect of Temperature on the Stability and Release Profile of Ibuprofen Microcapsules
...Show More Authors

The stability and releasing profile of 2:1 core: wall ratio ibuprofen microcapsules prepared by aqueous coacervation (gelatin and acacia polymers coat) and an organic coacervation methods (ethyl cellulose and sodium alginate polymers coat) in weight equivalent to 300mg drug, were studied using different storage temperatures 40°C, 50°C ,60°C and refrigerator temperature 4°C in an opened and closed container for three months (releasing profile) and four months (stability study).It was found that, these ibuprofen microcapsules were stable with expiration dates of 4.1 and 3.1 years for aqueous and an organic method respectively.Aqueous prepared ibuprofen microcapsules were found more stable than those microcapsules prepared by or

... Show More
View Publication Preview PDF
Crossref