Preferred Language
Articles
/
jbcd-3089
The relationship of implant stability quotient and insertion torque in dental implant stability
...Show More Authors

Background: The insertion torque (IT) values and implant stability quotient (ISQ) values are the measurements most used to assess primary implant stability. This study aimed to assess the relationship between ISQ values and IT. Materials and methods: This study included 24 patients with a mean (SD) age of 47.9 (13.64) years (range 25-75 years). The patients received 42 dental implants (DI), 33 in the mandible and 9 in the maxilla. The DI were installed using the motorized method with 35 Ncm torque, When DI could not be inserted to the requisite depth by the motorized method, a hand ratchet was used and the IT was recorded as ˃ 35 Ncm. Implant stability was measured utilizing Osstell® ISQ. The secondary stability was measured after 16 weeks postoperatively.Results: The DI installed in mandible demonstrated significantly higher primary stability ISQ values than those installed in maxilla (P=0.0101). There was no such significant correlation linked between the secondary stability and the recipient jaw (P=0.2026). A non-significant correlation was found between the primary and secondary implant stability ISQ values and IT (P=0.2785 and 0.4194, respectively). No significant difference was reported regarding the IT relative to the recipient jaw of DI (P=0.1349).Conclusion: This study demonstrated that there was no relationship between the ISQ values and the IT, and that they should be used independently. DI installed in mandible demonstrated significantly higher primary stability ISQ values than those installed in maxilla. Also, there was a non-significant correlation of the secondary stability and IT with the recipient jaw.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jun 03 2023
Journal Name
Iraqi Journal Of Science
Effect Effect Effect Effect Effect Effect Effect of Thickness on Some Physical PropertiesThickness on Some Physical PropertiesThickness on Some Physical PropertiesThickness on Some Physical PropertiesThickness on Some Physical Properties Thickness on Some
...Show More Authors

The effect of thickness variation on some physical properties of hematite α-Fe2O3 thin films was investigated. An Fe2O3 bulk in the form of pellet was prepared by cold pressing of Fe2O3 powder with subsequent sintering at 800 . Thin films with various thicknesses were obtained on glass substrates by pulsed laser deposition technique. The films properties were characterized by XRD, and FT-IR. The deposited iron oxide thin films showed a single hematite phase with polycrystalline rhombohedral crystal structure .The thickness of films were estimated by using spectrometer to be (185-232) nm. Using Debye Scherrerś formula, the average grain size for the samples was found to be (18-32) nm. Atomic force microscopy indicated that the films had

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 26 2020
Journal Name
Journal Of Global Pharma Technology
Synthesis, Characterization of 2-azido-4-(azido (2-azido-2-( azido carbonyl)-1,3-dioxoian-4-yl)methyl)– 5-((R-azido (hydroxyl) methyl- 1,3-dioxole-2-carbonyl azide. ethanol. hydrate (L-AZD) with Some Metal Complexes
...Show More Authors

The reaction oisolated and characterized by elemental analysis (C,H,N) , 1H-NMR, mass spectra and Fourier transform (Ft-IR). The reaction of the (L-AZD) with: [VO(II), Cr(III), Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and Hg(II)], has been investigated and was isolated as tri nuclear cluster and characterized by: Ft-IR, U. v- Visible, electrical conductivity, magnetic susceptibilities at 25 Co, atomic absorption and molar ratio. Spectroscopic evidence showed that the binding of metal ions were through azide and carbonyl moieties resulting in a six- coordinating metal ions in [Cr (III), Mn (II), Co (II) and Ni (II)]. The Vo (II), Cu (II), Zn (II), Cd (II) and Hg (II) were coordinated through azide group only forming square pyramidal

... Show More