Background: The insertion torque (IT) values and implant stability quotient (ISQ) values are the measurements most used to assess primary implant stability. This study aimed to assess the relationship between ISQ values and IT. Materials and methods: This study included 24 patients with a mean (SD) age of 47.9 (13.64) years (range 25-75 years). The patients received 42 dental implants (DI), 33 in the mandible and 9 in the maxilla. The DI were installed using the motorized method with 35 Ncm torque, When DI could not be inserted to the requisite depth by the motorized method, a hand ratchet was used and the IT was recorded as ˃ 35 Ncm. Implant stability was measured utilizing Osstell® ISQ. The secondary stability was measured after 16 weeks postoperatively.Results: The DI installed in mandible demonstrated significantly higher primary stability ISQ values than those installed in maxilla (P=0.0101). There was no such significant correlation linked between the secondary stability and the recipient jaw (P=0.2026). A non-significant correlation was found between the primary and secondary implant stability ISQ values and IT (P=0.2785 and 0.4194, respectively). No significant difference was reported regarding the IT relative to the recipient jaw of DI (P=0.1349).Conclusion: This study demonstrated that there was no relationship between the ISQ values and the IT, and that they should be used independently. DI installed in mandible demonstrated significantly higher primary stability ISQ values than those installed in maxilla. Also, there was a non-significant correlation of the secondary stability and IT with the recipient jaw.
Circular thin walled structures have wide range of applications. This type of structure is generally exposed to different types of loads, but one of the most important types is a buckling. In this work, the phenomena of buckling was studied by using finite element analysis. The circular thin walled structure in this study is constructed from; cylindrical thin shell strengthen by longitudinal stringers, subjected to pure bending in one plane. In addition, Taguchi method was used to identify the optimum combination set of parameters for enhancement of the critical buckling load value, as well as to investigate the most effective parameter. The parameters that have been analyzed were; cylinder shell thickness, shape of stiffeners section an
... Show MoreRestoration of degraded lands by adoption of recommended conservation management practices can rehabilitate watersheds and lead to improving soil and water quality. The objective was to evaluate the effects of grass buffers (GBs), biomass crops (BCs), grass waterways (GWWs), agroforestry buffers (ABs), landscape positions, and distance from tree base for AB treatment on soil quality compared with row crop (RC) (corn [
The rapid sprawl in urban areas caused by excessive production and consumption of goods (as driven by local poor social choices) has inevitably resulted in a major burden due to environmental degradation worldwide. Unfortunately, these traditional models of urban planning fail to properly account for the intricacies that permeate a modern city and are deficient in terms of their approach as they shape themselves within an environment largely divorced from natural systems, resulting in vast mismanagement of resources, guiding cities down trajectories where growth destroys both physical and cultural landscapes. As cities suffer from increasing scarcity, we advocate for regeneration and resilience to be embedded in advanced urban design approa
... Show More
ABSTRUCT
The main aim of this research has been associated with the study of relationship between competitive intelligence and strategic risk, and to deduct their specific trends, which are interpreted as predicted by research hypotheses according to a review of literature including prior studies. The basic theme of these hypotheses is related to the probability that declining levels of strategic risk and competitive positions of industrial companies is dependent upon the growing capacity to stay ahead of competitors in the market.
A purposive non-random
... Show MoreBackground: This in vitro study compares a novel calcium-phosphate etchant paste to conventional 37% phosphoric acid gel for bonding metal and ceramic brackets by evaluating the shear bond strength, remnant adhesive and enamel damage following water storage, acid challenge and fatigue loading. Material and Methods: Metal and ceramic brackets were bonded to 240 extracted human premolars using two enamel conditioning protocols: conventional 37% phosphoric acid (PA) gel (control), and an acidic calcium-phosphate (CaP) paste. The CaP paste was prepared from β-tricalcium phosphate and monocalcium phosphate monohydrate powders mixed with 37% phosphoric acid solution, and the resulting phase was confirmed using FTIR. The bonded premolars were exp
... Show MoreThis paper presents the implementation of a complex fractional order proportional integral derivative (CPID) and a real fractional order PID (RPID) controllers. The analysis and design of both controllers were carried out in a previous work done by the author, where the design specifications were classified into easy (case 1) and hard (case 2) design specifications. The main contribution of this paper is combining CRONE approximation and linear phase CRONE approximation to implement the CPID controller. The designed controllers-RPID and CPID-are implemented to control flowing water with low pressure circuit, which is a first order plus dead time system. Simulation results demonstrate that while the implemented RPID controller fails to stabi
... Show MoreIn this paper, a miniaturized 2 × 2 electro-optic plasmonic Mach– Zehnder switch (MZS) based on metal–polymer–silicon hybrid waveguide is presented. Adiabatic tapers are designed to couple the light between the plasmonic phase shifter, implemented in each of the MZS arms, and the 3-dB input/output directional couplers. For 6 µm-long hybrid plasmonic waveguide supported by JRD1 polymer (r33= 390 pm/V), a π-phase shift voltage of 2 V is obtained. The switch is designed for 1550 nm operation wavelength using COMSOL software and characterizes by 2.3 dB insertion loss, 9.9 fJ/bit power consumption, and 640 GHz operation bandwidth
In the geotechnical and terramechanical engineering applications, precise understandings are yet to be established on the off-road structures interacting with complex soil profiles. Several theoretical and experimental approaches have been used to measure the ultimate bearing capacity of the layered soil, but with a significant level of differences depending on the failure mechanisms assumed. Furthermore, local displacement fields in layered soils are not yet studied well. Here, the bearing capacity of a dense sand layer overlying loose sand beneath a rigid beam is studied under the plain-strain condition. The study employs using digital particle image velocimetry (DPIV) and finite element method (FEM) simulations. In the FEM, an experiment
... Show MoreBackground: Anaemia is a major public health concern and is one of the most prevalent health issue in women within reproductive age group.
Objective: to assess maternal knowledge related to anaemia during pregnancy.
Type of the study: A cross –sectional study.
Method: The study including 200 mothers who attended selected primary health care centres, Baghdad during November and December 2015, they completed a previously prepared questionnaire coveringsocio-demographic characteristics and knowledge regarding anaemia in 4 main domains. The responses were analysed by using frequency, percentage and percent score for each statement a
... Show More