Background: Determination of local bone mineral density (BMD) with cortical thickness and bone height may offer a comprehensive description of the bone the surgeon will encounter when he or she actually sets the implant. Quantitative computed tomography (CT) (i.e., quantitative interpretation of values derived from Hounsfield units with a suitable calibration procedure) is the modality of choice to determine BMD. The aim of the present clinical study is to determine the local bone density in dental implant recipient sites using computerized tomography. Material and method: The sample consisted of (72) Iraqi patients whom referred to Al-Kharkh General hospital, Spiral CT scan Department for bone quality and quantity assessment after one week of dental implants insertion, the average of bone density was measured for 120 areas indifferent sectors of maxilla and mandible in Hounsfield unite. Results: As a mean, males show higher bone density than females, decreased with increased age significantly, mandible show significantly higher bone density than maxilla. Maxilla revealed no significant difference between the three sectors, while in the mandible there was significant difference between posterior sector (613.1HU)and both anterior (821.3 HU) and premolar sectors (779.6 HU) with no significant difference between anterior and premolar sectors. Conclusion: CT-Scan may provide a valuable aid to predict bone quality at potential implant sites and could be used to assess the change of bone density around dental implants.
Urinary Schistosomiasis is one of important diseases that cause irritation and damage of urinary tract and other systems and tissues and can not be expected by doctors when diagnosing urinary tract diseases.The current study is conducted to investigate the prevalence of schistosomiasisin Baghdad / Al-Rusafa. 191urine samples were collected fromresidents ofsome areas of Al-Rusafain Baghdad governarate (Almashtal, Albaladyat, Alameen, Baghdad aljadida and Alnahrawan) for the period from March until the end of September 2010.The samples were examined by the precipitation and examination of micro hematuria by reagent strips. The total infection percentage was 9.42% (18/191) and was significantly higher in males compared tofemales12.64% (11/87)
... Show MoreThe geometric morphometric technique was used to study the variables in the shape and size wings of different populations of mosquitoes Culex quinquefasciatus from different Iraqi provinces Babylon, Baghdad and Wasit. The results showed that the average of centroid size were 366, 387.5 and 407.4 Micron in Babylon, Baghdad and Kut, respectively. The statistical analysis showed that there were no significant differences in the average of centroid size of all specimens and they belong to the same species.
Background: Asthma is a disease of the airways characterized by chronic inflammation associated with airway hyper-responsiveness and airway wall remodeling. Aims of the study: The aims of this study was to determine the prevalence of oral manifestations , identify different microorganism from oral micro flora and determination of salivary IgA and salivary flow rate in asthmatic patients taking different dose of Prednisolone in comparison with control group. Subjects, materials and methods: The study included 17 patients under treatment with Prednisolone (10-20 mg),15 patients take (20-30 mg) of Prednisolone and other 18 patients take (30 – 40mg) of Prednisolone, and 25 healthy control group (10 male and 15 female). Results : The mo
... Show MorePurpose: This study aimed to compare the stability and marginal bone loss of implants inserted with flapped and flapless approaches 8 weeks after surgery and 3 months after loading. Material and Methods: Thirty SLActive implants were inserted in 11 patients and early loaded with final restoration 8 weeks after healing period. The stability values determined by Osstell and the marginal bone loss measured by CBCT at the initial time (1st) and 8 weeks of the healing period (2nd) and 3 months after loading (3rd). Results: The overall survival rate was 100%. A significant increase in the 3rd implant stability value in the age of ˂ 40. A significant decrease in the 2nd implant stability value in both gender and traumatic zone with a flapless app
... Show MoreAbstract
Objectives: This study aimed to evaluate the effectiveness of an educational program on nurses' practices concerning therapeutic communication.
Methodology: A quasi experimental design was carried out at Karbala Center for Cardiac Diseases and Surgery, Imam Hussein Medical City and Al-Handia General Hospital for period 10th June 2017 to the 15th of August 2018.
The program and instruments were constructed and developed by the researcher to measure the purpose of the study. Purposive sample comprised of (57) nurses were divided into two groups, study and control groups. The questionnaire consisted from two parts, first part is related to nurses' demographic characteristics and second part which include practices checkl
Background: In the traditional protocol, the patient should wait after extraction up to six months to place the dental implant in healed bone, this waiting time accompanied by varying degrees of alveolar bone changes. In order to overcome these problems, immediate implant placement in the fresh extraction socket was introduced. The Aim of this study was to evaluate the outcome of the immediate implant placement utilizing Resonance Frequency Analysis (RFA) to quantify implant stability and osseointegration. Materials and Methods: A total of (23) patients participated in the study, receiving (44) implants placed in the sockets of teeth indicated for extraction. Clinical and radiographic preoperative assessment was accomplished for each patie
... Show MoreThe particle-hole state densities have been calculated for 232Th in
the case of incident neutron with , 1 Z Z T T T T and 2 Z T T .
The finite well depth, surface effect, isospin and Pauli correction are
considered in the calculation of the state densities and then the
transition rates. The isospin correction function ( ) iso f has been
examined for different exciton configurations and at different
excitation energies up to 100 MeV. The present results are indicated
that the included corrections have more affected on transition rates
behavior for , , and above 30MeV excitation energy
Three types of medical commercial creams Silvazine, Cinolon Tar and Hydroquinon Domina were incorporated in this study. The medical creams were taken directly and placed uniformly on the glass slide. Each type of pharmaceutical was weighed at 1 mg and dispersed on an area of 1x1 cm. This process ensures same thickness for all samples. The creams were analyzed by using double-beam UV/visible spectrophotometer Metertech SP8001. The absorption spectrum for each of samples was measured against wavelength range of 300–700 nm.
In this paper, there are two main objectives. The first objective is to study the relationship between the density property and some modules in detail, for instance; semisimple and divisible modules. The Addition complement has a good relationship with the density property of the modules as this importance is highlighted by any submodule N of M has an addition complement with Rad(M)=0. The second objective is to clarify the relationship between the density property and the essential submodules with some examples. As an example of this relationship, we studied the torsion-free module and its relationship with the essential submodules in module M.
Background: Dental implants act as infrastructure for fixed restoration to look like as a natural tooth. Osseointegration is a biological events and considered as a base for success of dental implant. The aim of this study is to evaluate the bond strength between bone and Ti implant coated with mixture of nano hydroxyapatite-chitosan-collagen compared with Ti implants coated with nano hydroxyapatite implanted in rabbit tibia, after different period of implantation time (two and six weeks) by torque removal test. Material and methods: 36 screws of commercially pure titanium; 8mm in length and 3mm diameter , 18 screws coated with mixture of nano hydroxyapatite-chitosan-collagen and18 screws coated with nano hydroxyapatite by dip coating. St
... Show More