Background: Determination of local bone mineral density (BMD) with cortical thickness and bone height may offer a comprehensive description of the bone the surgeon will encounter when he or she actually sets the implant. Quantitative computed tomography (CT) (i.e., quantitative interpretation of values derived from Hounsfield units with a suitable calibration procedure) is the modality of choice to determine BMD. The aim of the present clinical study is to determine the local bone density in dental implant recipient sites using computerized tomography. Material and method: The sample consisted of (72) Iraqi patients whom referred to Al-Kharkh General hospital, Spiral CT scan Department for bone quality and quantity assessment after one week of dental implants insertion, the average of bone density was measured for 120 areas indifferent sectors of maxilla and mandible in Hounsfield unite. Results: As a mean, males show higher bone density than females, decreased with increased age significantly, mandible show significantly higher bone density than maxilla. Maxilla revealed no significant difference between the three sectors, while in the mandible there was significant difference between posterior sector (613.1HU)and both anterior (821.3 HU) and premolar sectors (779.6 HU) with no significant difference between anterior and premolar sectors. Conclusion: CT-Scan may provide a valuable aid to predict bone quality at potential implant sites and could be used to assess the change of bone density around dental implants.
A new data for Fusion power density has been obtained for T-3He and T-T fusion reactions, power density is a substantial term in the researches related to the fusion energy generation and ignition calculations of magnetic confined systems. In the current work, thermal nuclear reactivities, power densities of a fusion reactors and the ignition condition inquiry are achieved by using a new and accurate formula of cross section, the maximum values of fusion power density for T-3He and TT reaction are 1.1×107 W/m3 at T=700 KeV and 4.7×106 W/m3 at T=500 KeV respectively, While Zeff suggested to be 1.44 for the two reactions. Bremsstrahlung radiation has also been determined to reaching self- sustaining reactors, Bremsstrahlung values are 4.5×
... Show MoreThe Gaussian orthogonal ensemble (GOE) version of the random matrix theory (RMT) has been used to study the level density following up the proton interaction with 44Ca, 48Ti and 56Fe.
A promising analysis method has been implemented based on the available data of the resonance spacing, where widths are associated with Porter Thomas distribution. The calculated level density for the compound nuclei 45Sc,49Vand 57Co shows a parity and spin dependence, where for Sc a discrepancy in level density distinguished from this analysis probably due to the spin misassignment .The present results show an acceptable agreement with the combinatorial method of level density.
... Show MoreBackground: Prophylaxis methods are used to mechanically remove plaque and stain from tooth surfaces; such methods give rise to loss of superficial structure and roughen the surface of composites as a result of their abrasive action. This study was done to assess the effect of three polishing systems on surface texture of new anterior composites after storage in artificial saliva. Materials and methods: A total of 40 Giomer and Tetric®N-Ceram composite discs of 12 mm internal diameter and 3mm height were prepared using a specially designed cylindrical mold and were stored in artificial saliva for one month and then samples were divided into four groups according to surface treatment: Group A (control group):10 specimens received no surfa
... Show MoreABSTRACT Background:Hydrogen absorption and related degradation in the mechanical properties of Ni-Ti based orthodontic wires has been demonstrated following exposure to fluoride prophylactic agents. This study was designed to investigate the effects of three fluoride containing agents on the load deflection characteristics of heat activated nickel titanium arch wires during unloading phase. Material and method: Eighty specimens of heat activated nickel titanium arch wires were obtained from Ortho Technology Company, half of which had a 0.016 inch round and 0.019x0.025 rectangular. Ten specimens from both wire size were immersed in one of the tested fluoride prophylactic agents (neutral sodium fluoride gel, stannous fluoride gel or phos-flu
... Show MoreBackground: The purpose of this study was to assess the relation among the ramal length and width with various cervical and cranio-facial measurements for a sample of Iraqi adults with different skeletal classes. Materials and method: The sample composed of 71 Iraqi adults (36 females and 35 males) with an age ranged between 17-30 years and had different skeletal mal-relations using SNA, SNB and ANB to differentiate between them and assorting them into CL.I, CL.II and CL.III mal-relation. Each individual was subjected to clinical examination and digital true lateral cephalometric radiograph that had been analyzed using AutoCAD 2007 software computer program to determine sixteen linear and ten angular measurements. Descriptive statistics wer
... Show MoreThe study aims to develop the awareness of the criteria for judging electronic educational materials among students of educational qualification at Dhofar University over spreading the Corona pandemic through a program based on mini-educational units. The study was applied to (18) students studying Teaching diploma at Dhofar University for the academic year 2020-2021, and their number. They were chosen intentionally. The study resulted in reaching a list of criteria for judging electronic educational materials, roughly (18) criteria in the selection themes and (15) criteria in the use theme. The level of awareness of the sample members with the criteria for selecting and using electronic educational materials and the effectiveness of the
... Show MoreAbstract Background: One of the most important methods to replace lost teeth is dental implants. In order to increase the strength of connection of the implant with the jaw bone to provide early loading after placement, implant is coated by different coating materials that achieved that purpose. The aim of this study was to evaluate the influence of coating CP Ti implant with calcium carbonate on the strength of bone-implant interface after two and six weeks of implantation in rabbit femur bone by torque removal test, histological and histomorphometric analysis. Materials and methods: Coating the surface of commercially pure titanium screws with extra pure synthetic calcium carbonate via electrophoretic deposition method (EPD) was done. The
... Show MoreObjectives: To evaluate levels of nurses' knowledge about substance abuse at psychiatric teaching hospitals in Baghdad city. Methodology: A descriptive analytical study conducts to meet study objectives during the period from 1-11-2014 To 10-5-2015 The study conduct at 4 teaching hospitals in three department (Baghdad Al Rusafa ,Al Karkh, Medical city) they includ Baghdad teaching hospital, Al Rashad teaching hospital, Ibn Rshud teaching hospital , and Al Kadhumeeain teaching hospital which select according to the study. A random sample of 100 nurses are working in teaching psychiatric hospitals , Al Rashad (6