Background: Implant stability is a mandatory factor for dental implant (DI) osseointegration and long-term success. The aim of this study was to evaluate the effect of implant length, diameter, and recipient jaw on the pre- and post-functional loading stability. Materials and methods: This study included 17 healthy patients with an age range of 24-61 years. Twenty-two DI were inserted into healed extraction sockets to replace missing tooth/ teeth in premolar and molar regions in upper and lower jaws. Implant stability was measured for each implant and was recorded as implant stability quotient (ISQ) immediately (ISQ0), and at 8 (ISQ8) and 12 (ISQ12) weeks postoperatively, as well as post-functional loading (ISQPFL). The pattern of implant stability changes throughout the study period and its correlation with the recipient jaw and the DI dimensions were evaluated. Results: There was a significant difference in ISQ values throughout the study. DI stability in the maxilla was significantly higher than that in mandible for the ISQ0, with no significant effect for the rest time points. The effect of implant diameter was significant with DI of 4.1mm diameter being more stable. While for the length, there was no significant difference regarding its effect on ISQ values through-out the study period. Conclusions: DI inserted in the maxilla demonstrated better primary stability with no effect of recipient jaw on secondary stability and after functional loading, also DI with wider diameter had better stability throughout the study whereas DI length showed no significant effect on stability
The presentwork is a theoretical study in the field of charged particle optics. It concentrates on the design of electrostatic enzil lens for focusing charge particles beams, using inverse method in designingthe electrostatic lens. The paraxial ray equation was solved to obtain the trajectory of the particles, the optical properties such as the focal length and spherical and chromatic aberration coefficients were determined. The shape of the electrode of the electrostatic lens were determined by solving poison equation and the results showed low values of spherical and chromatic aberrations, which are considered as good criteria for good design.
Four metal compounds mixed ligand of azo dye ligand (L) and metformin.(Met) were produced at aquatic ethanol for (1:1:1) (M:L:Met). The prepared compounds were identified by utilizing atomic absorption flame, FT.IR and UV–Vis spectrum manners as well as conductivity mensuration. These compounds was assayed of the gained datum the octahedral geometry was proposed into whole prepared complexes.Also in this research was studied represented examining the antibacterial and antifungal impact of the azo dye ligand (L), metformin.(Met) and (Co,Ni, Cu and Cd complexes) on four types of pathogenic, clinically isolated bacteria that are resistant to antibiotic, like Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli, Klebsiella pneu
... Show MoreBackground: Chief complaint of patients attending dental clinic represents the first step towards treatment plan. However, most of patients are not aware but the extent and severity of periodontal disease, which could be also, misdiagnose by the dentist. Aim of the study: To investigate whether reported chief complaint(s) are consistent with oral hygiene status Materials and methods: Records of 1102 patients, attending periodontics clinics in the college of dentistry/ university of Baghdad, were used to determine ten most commonly reported chief complaints. Sample of patients was further subdivided according to gender and age. In addition, plaque and gingival index were recorded to determine oral hygiene status. Results: Patients mostly
... Show MoreIrrigation has significant role in endodontic treatment, many types of antimicrobial irrigation solutions have been used, but due to the ineffectiveness, safety concerns and side effects of this irrigation, the herbal alternatives for endodontic irrigants might be beneficial. Objectives This study compared the in vitro effectiveness of tea tree oil and clove oil as possible irrigants in endodontics against Enterococcus faecalis in comparison with 3% Sodium hypochlorite. Materials and Methods E. faecalis was isolated from patients in need for endodontic treatment; VITEK was employed for E. faecalis isolate conformation. Muller Hinton agar was prepared with 100μl of freshly prepared suspension of E.faecalis. Wells of 6mm diameter and 4mm dep
... Show MoreIrrigation has significant role in endodontic treatment, many types of antimicrobial irrigation solutions have been used, but due to the ineffectiveness, safety concerns and side effects of this irrigation, the herbal alternatives for endodontic irrigants might be beneficial. Objectives This study compared the in vitro effectiveness of tea tree oil and clove oil as possible irrigants in endodontics against Enterococcus faecalis in comparison with 3% Sodium hypochlorite. Materials and Methods E. faecalis was isolated from patients in need for endodontic treatment; VITEK was employed for E. faecalis isolate conformation. Muller Hinton agar was prepared with 100μl of freshly prepared suspension of E.faecalis. Wells of 6mm diameter and 4mm dep
... Show More