Background: The interest in herbal extracts as antimicrobial agents has increased over the past few years in endodontic therapy. Nasturtium officinale (watercress) is a promising plant with great medicinal values. This study aimed to investigate the antifungal activity of watercress oil in combination with calcium hydroxide against Candida albicans as intracanal medicament. Materials and Methods: Candida albicans was isolated from patients with necrotic root canal or failed root canal treatment. The sensitivity of Candida albicans to different concentrations of watercress oil extract was determined by using the agar well diffusion method in comparison with calcium hydroxide paste. The agar plate method was used to determine the minimum fungicidal concentration (MFC) of the tested oil against the fungus. The combination of the oil extract of Nasturtium officinale with calcium hydroxide was evaluated and compared to calcium hydroxide paste with iodoform by using the agar well diffusion method. Results: The oil extract exhibited antifungal activity against Candida albicans, this activity was found to be increased as the concentration of extract increased. The tested combination of watercress oil extract with calcium hydroxide revealed larger inhibition zones than the ones formed by each tested agent individually. Conclusion: The oil extract of Nasturtium officinale is active against Candida albicans suggesting its potential to be used as an intracanal medicament alone or in combination with calcium hydroxide.
In :the _pr sent _paper we report ths. ynthesis ·of a new li:ga!!d..
[f4LJ [{'2 {1-'[(2-hyd•:0xy-.ben:zy1i.den·e)..,bxcJrazanci}:etby-l }benzerieÂ
J,5 t;rtiol .aad its complexes ·w-ith '('Mlif(1 J Fev 1 ), ed(J'l), and. :f.::I:g 01>-)
The ligand \VS preP..ated rin tWo steps' • fp I t}Je nrst stea -soJutiQil Qf
-saUcyla[deeyeq. ip methatt:oJ . re3ctcd lU1der reflux
... Show MorePilot-scale dead end microfiltration membranes were carried out to determine the feasibility of the process for treating the oily wastewater which discharge from some Iraqi factories such as power station of south of Baghdad and the general company of petrochemical industries. Polypropylene membranes (cylindrical shape) with different pore diameters (1 and 5 micron) were used to conduct the study on micromembrane process. The variables studied are oil concentration (100 – 1000 ppm), feed flow rate (20 – 40 l/h), operating temperature (31 – 50°C) and time (0 – 3 h). It was found that the flux increases with increasing feed flow rate, temperature and pore size of membrane, and decreases with increasing oil concentration and operating
... Show MoreBuilding a 3D geological model from field and subsurface data is a typical task in
geological studies involving natural resource evaluation and hazard assessment. In
this paper a 3D geological model for Asmari Reservoir in Fauqi oil field has been
built using petrel software. Asmari Reservoir belongs to (Oligocene- Lower
Miocene), it represents the second reservoir products after Mishrif Reservoir in Fauqi
field. Five wells namely FQ6, FQ7, FQ15, FQ20, FQ21 have been selected lying in
Missan governorate in order to build Structural and petrophysical (porosity and water
saturation) models represented by a 3D static geological model in three directions
.Structural model shows that Fauqi oil field represents un cylin
Eight different Dichloro(bis{2-[1-(4-R-phenyl)-1H-1,2,3-triazol-4-yl-κN3]pyridine-κN})iron(II) compounds, 2–9, have been synthesised and characterised, where group R=CH3 (L2), OCH3 (L3), COOH (L4), F (L5), Cl (L6), CN (L7), H (L8) and CF3 (L9). The single crystal X-ray structure was determined for the L3 which was complemented with Density Functional Theory calculations for all complexes. The structure exhibits a distorted octahedral geometry, with the two triazole ligands coordinated to the iron centre positioned in the equatorial plane and the two chloro atoms in the axial positions. The values of the FeII/III redox couple, observed at ca. −0.3 V versus Fc/ Fc+ for complexes 2–9, varied over a very small potential range of 0.05 V.
... Show MoreThe purpose of this study was to find out the connection between the water parameters that were examined in the laboratory and the water index acquired from the examination of the satellite image of the study area. This was accomplished by analysing the Landsat-8 satellite picture results as well as the geographic information system (GIS). The primary goal of this study is to develop a model for the chemical and physical characteristics of the Al-Abbasia River in Al-Najaf Al-Ashraf Governorate. The water parameters employed in this investigation are as follows: (PH, EC, TDS, TSS, Na, Mg, K, SO4, Cl, and NO3). To collect the samples, ten sampling locations were identified, and the satellite image was obtained on the
... Show MoreConcentration of natural occurring radioactive material (NORM) in Markazia Degasing Station in North Rumaila oilfield (NDS) was measured in this study. Then, radiological assessment due to existing of NORM in different samples including soil, sludge, scale, oil, and water collected from different stages of oil and gas production NDS was done. Radioactivity concentration of Ra-226, Th-232 and K-40 were measured using gamma spectrometry system based on HPGe detector with efficiency of 30%. The results show that some locations within NDS are contaminated with NORM. The activity in Bq/kg of Ra-226, Th-232 and K-40 range between 15.19 in oil to 68.73 in sludge, 8.5 in oil to 23.45 in sludge and 80.23 in oil to 319.73 in saline water samples r
... Show MoreAn indirectly method is used to determine hydrogen peroxide. The method based on oxidation of chromium (III) ion by hydrogen peroxide in basic medium to form chromate ion which react with barium (II) ion to produce a yellow precipitate (BaCrO4). Under the optimum established conditions, the linear range of 0.50-25.00 mmol L-1 along with correlation coefficient (r) of 0.9992, Limit of detection (LOD) 0.68 μg / 100 μL, precision expressed as relative standard deviation for six replication measurements at 5.0 mmol.L-1 H2O2 of less than 2% were obtained for hydrogen peroxide. The developed method was successfully applied for the estimation of H2O2 in three pharmaceuticals preparation of different companies using continuous flow injection o
... Show More