Background: The bond strength of endodontic sealers with dentin is a very important property for maintaining the integrity and seal of the root canal filling. The aim of this study was to evaluate and compare the effect of various irrigants (QMix, 17% EDTA and 2.5% NaOCl) on the push-out bond strength of AH plus and Bioceramic sealers. Materials and methods: Forty eight freshly extracted maxillary first molars human teeth with striaght palatal root were used in the study. The collected samples were randomly divided into three groups of equal sample size (n=16), according to the final irrigation regimen as follows: Group (1): QMix 2 in 1, Group (2): 17% ethylenediaminetetraacetic acid, Group (3): 2.5% sodium hypochloride. All samples were instrumented using Edge file X7 rotary instrument reaching file size 40/.04 as the final master apical file. After that each group was randomly divided into two subgroups (n=8) according to the type of sealer used: AH Plus and Total Fill BC Sealer. Obturation was conducted using single cone technique with gutta percha (GP) to all experimental roots. Two-millimeter thick slices were obtained from the middle section of the root. Bond strength of sealers was measured via a universal testing machine by using stainless steel plunger. Then, the data were statistically evaluated using two-way analysis of variance (ANOVA) and post hoc test (Bonferroni’s test). Results: The push-out bond strength was significantly increased by the “irrigant†factor (P≤0.05) and by “sealer/irrigation solution†interaction (P≤0.05). Final rinse with QMix solution with BC sealer showed the highest mean value of bond strength (5.976 MPa), with a significant difference with other groups (P≤0.05), while NaOCl with AH Plus sealer showed the lowest mean value of bond strength (3.811 MPa). Conclusion: Final irrigation of the root canals with different irrigants improved the endodontic sealer's bond strength, and QMix had a positive influence on the adhesion of BC sealer.
The importance of the research lies in preparing an experimental curriculum according to a scientific method that will contribute to the development of the special strength(endurance the strength of arms) in order to contribute to the attempt to develop the basic skills of the national team players with the goal ball for the blind As for the research problem, it lies in the weakness of the strength endurance of the national team players with the goal ball for the blind, as the research problem is clearly evident in the last minutes of the match, as well as the former studies in the field of goal ball game for the blind at the country level The research aims to prepare special exercises for endurance of strength as well as t
... Show MoreThis paper presents the results of experimental investigation carried out on concrete model piles to study the behaviour of defective piles. This was achieved by employing non-destructive tests using ultrasonic waves. It was found that the reduction in pile stiffness factor is found to be about (26%) when the defect ratio increased from (5%) to (15%). The modulus of elasticity reduction factor as well as the dynamic modulus of elasticity reduction factor increase with the defect ratio
Non-thermal argon plasma needle at atmospheric pressure was
constructed. The experimental setup was based on a simple and low
cost electric component that generates a sufficiently high electric
field at the electrodes to ionize the argon gas which flow at
atmospheric pressure. A high AC power supply was used with 1.1
kV and 19.57 kHz. Non-thermal Argon plasma used on blood
samples to show the ability of non-thermal plasma to promote blood
coagulation. Three tests have been done to show the ability of plasma
to coagulate both normal and anti-coagulant blood. Each blood
sample has been treated for varying time from 20sec. to 180sec. at
different distances. The results of the current study showed that the
co
In this study, hydroxyapatite (HAP, Ca10(PO4)6(OH)2) has been prepared as bioceramic material with biological specifications useful to used for orthopedic and dental implant applications. Wet chemical processing seems to form the fine grain size and uniform characteristic nanocrystalline materials by the interstice factors controlling which affected the grain size and crystallinity in order to give good mechanical and/or constituent properties similar as natural bone. Fluorinated hydroxyapatite [4-6 wt% F, (FHA, Ca10(PO4)6(OH)2–Fx] was developed in new method for its posses to increased strength and to give higher corrosion resistance in biofluids than pure HAP moreover reduces the risk of dental caries. The phase's and functional groups
... Show MoreHydrocarbon displacement at the pore scale is mainly controlled by the wetness properties of the porous media. Consequently, several techniques including nanofluid flooding were implemented to manipulate the wetting behavior of the pore space in oil reservoirs. This study thus focuses on monitoring the displacement of oil from artificial glass porous media, as a representative for sandstone reservoirs, before and after nanofluid flooding. Experiments were conducted at various temperatures (25 – 50° C), nanoparticles concentrations (0.001 – 0.05 wt% SiO2 NPs), salinity (0.1 – 2 wt% NaCl), and flooding time. Images were taken via a high-resolution microscopic camera and analyzed to investigate the displacement of the oil at dif
... Show MoreHydrocarbon displacement at the pore scale is mainly controlled by the wetness properties of the porous media. Consequently, several techniques including nanofluid flooding were implemented to manipulate the wetting behavior of the pore space in oil reservoirs. This study thus focuses on monitoring the displacement of oil from artificial glass porous media, as a representative for sandstone reservoirs, before and after nanofluid flooding. Experiments were conducted at various temperatures (25 – 50° C), nanoparticles concentrations (0.001 – 0.05 wt% SiO2 NPs), salinity (0.1 – 2 wt% NaCl), and flooding time. Images were taken via a high-resolution microscopic camera and analyzed to investigate the displacement of the oil
... Show Moreobjective: To evaluate the influence of monolithic zirconia brand, thickness, and substrate color on color matching accuracy when optically coupled to abutment substrates. Methods: A total of 180 samples of two brands of monolithic zirconia [Prettau Anterior (PA), Ceramill Zolid FX Multicolor (CZ)] were prepared in three different thicknesses (0.8 mm, 1.5 mm, and 2 mm) with a standardized 10 mm diameter. Color properties of the samples were assessed using spectrophotometry at baseline and after coupling to three substrate types: standard dentin, discolored dentin, and titanium. Color differences (ΔE) were calculated and statistically analyzed by 3-way ANOVA and pairwise comparison ( α=0.05). Results: The brand and material thickness, at
... Show MoreAlopecia areata is a common disorder, hypothesized to be autoimmune in etiology. Cortisone taken orally may stimulate new hair growth. Prednisone (orally administered steroid (has proved effective for patients with alopecia areata, but its potential side effects include weight gain, metabolic abnormalities, acne and menstrual problems.
This clinical study was designed to assess the clinical significance of the nutrient antioxidants (vitamin A, vitamin E and vitamin C) in reducing the dose of corticosteroids (prednisolone), and as a consequence, their side effects in patient with alopecia. The results of this study reveal the potential clinical significance of the therapy for two months with these antioxidants in reducing the dose
... Show MoreBackground: Marginal adaptation is critical for long – term success of crown and bridge restoration. Computer aided design / computer aided manufacture (CAD/ CAM) system is gaining more importance in the fabrication of dental restoration. Objective: The aim of this study is to evaluate the effect of crystallization firing on the vertical marginal gap of IPS. emax CAD crowns which fabricated with two different CAD/CAM systems .Materials and Methods: Twenty IPS e.max CAD crowns were fabricated. We had two major groups (A, B) (10 crowns for each group) according to the CAD/CAM system being used: Group A: fabricated with Imes - Icore CAD/CAM system; Group B: fabricated with In Lab Sirona CAD/CAM system. Each group was subdivided into two s
... Show More