Background: Poly-ether-ether-ketone(PEEK) has been introduced to many dental fields. Recently it was tested as a retainer wire‎ following orthodontic treatment. This study aimed to investigate the effect of changing the bonding spot size and location on the performance of PEEK retainer wires. Methods: A biomechanical study involving four three-dimensional finite element models was performed. The basic model was with a 0.8 mm cylindrical cross-section PEEK wire, bonded at the center of the lingual surface of the mandibular incisors with 4 mm in diameter composite spots. Two other models were designed with 3 mm and 5 mm composite sizes. The last model was created with the composite bonding spot of the canine away from the center of the crown, closer to the lateral incisor. The linear displacement of the teeth, strains of the periodontal ligament, and stresses in PEEK wire and composite were evaluated. The data was numerically produced with color coded display by the software. Selected values were tabulated and compared among models. Results: The amount of linear displacement and strain was very low. Stresses in the wire and composite were affected by the size and position of the composite bonding spot. The safe limits were identified at 235 MPa for PEEK and 100 MPa for composite. The basic model had a von Mises stress in the PEEK wire of 122.09 MPa, and a maximum principal stress in the composite of 99.779 MPa. Both stresses were within the safe limits, which means a lower risk of failure in PEEK and composite. All other models had stresses that exceeded the safe limit of the composite. The 3 mm composite model was the only one that developed stresses in the wire more than the safe limits of PEEK. Conclusions: Within the limitations of this study, bonding PEEK wires with 4 mm bonding spots to the clinical crown center provided the best mechanical performance of the wires and spots; otherwise, the mechanical properties of the wire and composite would be affected and, therefore, might affect the retention process. Keywords: Retention, PEEK, Finite element analysis
Healthcare professionals routinely use audio signals, generated by the human body, to help diagnose disease or assess its progression. With new technologies, it is now possible to collect human-generated sounds, such as coughing. Audio-based machine learning technologies can be adopted for automatic analysis of collected data. Valuable and rich information can be obtained from the cough signal and extracting effective characteristics from a finite duration time interval that changes as a function of time. This article presents a proposed approach to the detection and diagnosis of COVID-19 through the processing of cough collected from patients suffering from the most common symptoms of this pandemic. The proposed method is based on adopt
... Show MoreThe present study aimed to investigate the effects of level pH and the growth phases of Coelastrella saipanensis on Chlorophyll a,b, total, and Carotene. The algae were cultured in BG11 media and grown at different pH levels. We measured chlorophyll a, b, total chlorophyll, growth phases, and carotene concentrations. The results showed that at pH 8.5, the measurements of photosynthetic pigments-chlorophyll a, Chlorophyll b, and the total chlorophyll (0.183, 0.268, and 0.433 mg L-1, respectively). The highest values of chlorophyll a (0.185 mg L-1), and b (0.339 mg L-1), and the total chlorophyll (0.492 mg L-1) were recorded in the stationary phase. In addition, the study found that at pH 8.5 and the beginning of the stationary phase,
... Show MoreThis study aimed to explore the manufacture of high-fat pellets for obesity induction diets in male Wistar rats and determined its effect on lipid profiles and body mass index. It was an experimental laboratory method with a post-test randomized control group. Formulation of high-fat pellets (HFD) and physico-chemical characteristics of pellets were conducted in September 2019. This study used about 28 male Wistar white rats, two months old, and 150-200 g body weight. Rats were acclimatized for seven days, then divided into four groups: 7 rats were given a standard feed of Confeed PARS CP594 (P0), and three groups (P1, P2, P3) were given high-fat feed (HFD FII) 30 g/head/day. The result showed that the mean fat content of Formula II pell
... Show MoreRandom laser gain media is synthesized with different types of dye at the same concentration (1×10-3 M) as an active material and silicon dioxide NPs (silica SiO2) as scatter centers through the Sol-Gel technique. The prepared samples are tested with UV–Vis spectroscopy, Fluorescence Spectroscopy, Field Emission Scanning Electron Microscopy (FESEM), and Energy Dispersive X-ray Diffraction (EDX). The end result demonstrates that doped dyes with silica nanoparticles at a concentration of 0.0016 mol/ml have lower absorbance and higher fluorescence spectra than pure dyes. FESEM scans revealed that the morphology of nanocrystalline silica is clusters of nano-sized spherical particles in the range (25-67) nm. It is con
... Show MoreThe article presents the results of studies of the species composition of phytopathogens of winter soft wheat grain affected by ear fusarium. For the first time, studies were conducted using a complex of electron microscopic, molecular genetics, and mycological methods. The species F. graminearum dominated in all samples (frequency of occurrence 42.8%). The species F. avenaceum (23.3%), F. sporotrichioides and F. equiseti (8.8% each) were noted with high frequency. Next in descending order of frequency of occurrence: F. oxysporum, F. boothii, F. poae, F. proliferatum, F. accumatum, F. incarnatum, F. vorosii, F. tricinctum, F. cerealis, F. sambuticum. For the first time, 7 species were found for the plain zone of the Pre-Caucasus: F.
... Show MoreThe current study aims to develop a proposed educational program based on augmented reality (AR) technology, in addition to assessing its effectiveness in developing research and historical imagination skills of the Humanities Track's female students at the secondary stage, as well as assessing the correlative and predictive relationships between the amount of growth for the two dependent variables. To achieve this, a secondary school in the city of Makkah Al-Mukarramah was chosen, and an available random sample of (30) female students from the study population was selected. The quasi-experimental approach was followed by this study, particularly one group design. In addition, two tools were used to collect study data, namely: a test of
... Show MoreThe study aims to verify the independence of auditors working in companies and offices of the Iraqi audit, and measure the level of accounting conservatism in the financial statements of banks and insurance companies listed on the Iraq Stock Exchange, as well as a statement after the independence of the auditor on accounting conservatism in the financial statements of banks and insurance companies listed on the market Iraq Stock Exchange, as it has been measuring the independence of the auditor using the survey form was auditors working in the Iraqi audit firms were measured the level of accounting conservatism for companies sample using a form( Basu) was a statement after variables through the use of statistical models in a mann
... Show MoreThe bubble columns are widely used as a two or three phase reactor in industrial chemical process such as absorption, biochemical reactions, coal liquefaction, etc. To design such a column, two main parameters should be taken in consideration, the gas hold-up (), and the liquid phase mass transfer coefficient KLa. The study includes the effect of gas velocity and the addition of alcohols on gas hold-up and mass transfer coefficient in bubble column with draught tube when the length of the column is 1.5m and the ratio of the draught tube diameter to the column diameter equals 0.5 and the air dispersion into the base of the draught tube using a multi hole tuyere is equivalent to a diameter of 0.15 mm and
... Show More