Preferred Language
Articles
/
jbcd-2911
Coated stainless steel archwires' discoloration measured by computerized system (An in-vitro study)
...Show More Authors

Background: Aesthetic archwires are used to overcome the aesthetic problems of stainless steel wires but the color of the coating layer can be changed with time when exposed to oral environments. The aim of this study was to evaluate the degree of color change of different aesthetic archwires from different companies under different coloring solutions. Materials and Methods: One hundred fifty samples of coated archwires from three companies (Highland, G&H and Dany) were immersed in 5 solutions (artificial saliva, turmeric, tea, coffee and Miranda) to evaluate the degree of color changes after 7, 14 and 21 days using visible spectrophotometer. Data were collected and analyzed using one way ANOVA and post hoc Tukey’s tests. Results: Turmeric solution caused high color change than other solutions. Aesthetic archwires from Highland company showed the highest degree of color change than archwires from other companies. Conclusions: Turmeric solution produced more discoloration than other solutions and the effects of these solutions are related to different chemical compositions of those solutions.

 

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jan 01 2012
Journal Name
International Journal Of Reasoning-based Intelligent Systems
SLMS: a smart library management system based on an RFID technology
...Show More Authors

View Publication
Scopus (23)
Crossref (13)
Scopus Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Spot Welding of Dissimilar Metals Using an Automated Nd:YAG Laser System
...Show More Authors

An assembled pulsed Nd:YAG laser-robot system for spot welding similar and dissimilar metals is presented in this paper. The study evaluates the performance of this system through investigating the possibility and accuracy of executing laser spot welding of 0.2 mm in thickness stainless steel grade AISI302 to 0.5 mm in thickness low carbon steel grade AISI1008. The influence of laser beam parameters (peak power, pulse energy, pulse duration, repetition rate, and focal plane position on the final gained best results are evaluated. Enhancement of the experimental results was carried by a computational simulation using ANSYS FLUENT 6.3 package code.

View Publication Preview PDF
Publication Date
Tue Sep 01 2015
Journal Name
Journal Of Engineering
Performance Enhancement of a Piezoelectric Harvester Included into an Autonomous System
...Show More Authors

Autonomous systems are these systems which power themselves from the available ambient energies in addition to their duties. In the next few years, autonomous systems will pervade society and they will find their ways into different applications related to health, security, comfort and entertainment. Piezoelectric harvesters are possible energy converters which can be used to convert the available ambient vibration energy into electrical energy. In this contribution, an energy harvesting cantilever array with magnetic tuning including three piezoelectric bimorphs is investigated theoretically and experimentally. Other than harvester designs proposed before, this array is easy to manufacture and insensitive to manufacturi

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Engineering
An Electronic and Web-Based Authentication, Identification, and Logging Management System
...Show More Authors

The need for participants’ performance assessments in academia and industry has been a growing concern. It has attendance, among other metrics, is a key factor in engendering a holistic approach to decision-making. For institutions or organizations where managing people is an important yet challenging task, attendance tracking and management could be employed to improve this seemingly time-consuming process while keeping an accurate attendance record. The manual/quasi-analog approach of taking attendance in some institutions could be unreliable and inefficient, leading to inaccurate computation of attendance rates and data loss. This work, therefore, proposes a system that employs embedded technology and a biometric/ w

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Oct 02 2018
Journal Name
Iraqi Journal Of Physics
Study of in vitro and in vivo free radical scavenging activity for radioprotection of cerium oxide nanoparticles
...Show More Authors

Nanoceria have shown numerous unique characteristics, such as biocompatibility and are excellent agents for biological applications. The aim of this study is to investigate cerium oxide nanoparticles for 2, 2- diphenyl-1-picryl-hydrazyl-hydrate (DPPH) free radical scavenging activity and their ability to offer protection against ionizing radiation. In vitro antioxidant activity study of nanoceria particles has shown good free radical scavenging activity for DPPH radical assayed within a concentration range of 0.01 to 0.05 g/l, at higher concentrations of nanoparticles showed reverse trend in absorbance and inhibition indicating this finite rang of concentration is suitable for scavenging free radicals, also nanoparticles were found to ha

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Sun Dec 05 2010
Journal Name
Iraqi Journal Of Laser
Comparative Histological Study of Dentinopulpal Responses in Class I Cavity Treated by Er: YAG Laser and Conventional Cavity Preparations: An in Vivo Trial
...Show More Authors

The purpose of this study is to investigate the histopathological response of dentinopulpal
response of human teeth to the Er: YAG laser cavity preparation in comparison with the conventional
class I cavity preparation. Thirty five sound human upper and lower first premolar teeth which were
needed to be extracted for orthodontic purposes were used in the study. Regarding to the method of
cavity preparation, the teeth were grouped into three groups; Group1; Control group which consists of
seven sound teeth without cavity preparation, Group2; Conventional cavity preparation group and group
3; Er: YAG laser cavity preparation group. Each of Group2 and3 consists of fourteen teeth that is
subdivided into: A. 7teeth that e

... Show More
View Publication Preview PDF
Publication Date
Fri Jun 30 2006
Journal Name
Al-kindy College Medical Journal
The Use of Spiral Computerized Tomography in the Diagnosis of Middle –Third Facial Fractures as Compared to Plain Radiography
...Show More Authors

Background: Trauma is one of the most common
clinical problems that confront the maxillofacial
surgeon and radiologist alike. Middle third facial
fractures are diagnosed primarily on the bases of
clinical examination and plain radiographs than can
result in much preoperative speculation.
Objective: To assess the advantages of spiral
computerized tomography over conventional
radiography in the pre-surgical evaluation of middle
third facial fractures.
Methods: Thirty patients with thirty-eight facial
fractures were studied, all patients were examined
clinically, by plain radiography and then by spiral CT.
Results: Of the 38 middle-third fractures, 16
(42.1%) were zygomatic fractures, 8 (21.1%) were

... Show More
View Publication Preview PDF
Publication Date
Tue Aug 01 2017
Journal Name
International Journal Of Scientific & Engineering Research
Integrated System of Information hiding by Applying Three levels
...Show More Authors

MB Mahmood, BN Dhannoon

View Publication
Publication Date
Thu Sep 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Corrosion Inhibition of Steel Reinforcement in Concrete
...Show More Authors

View Publication Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Research Journal Of Pharmacy And Technology
Corrosion behavior of implant coated with different biocompatible material
...Show More Authors

View Publication
Scopus (5)
Crossref (5)
Scopus Crossref