Background: This in vitro study was carried out to investigate the effect of post space regions (coronal, middle and apical), the effect of post types ( Manually Milled Zirconia post, Prefabricated Fiber post, prefabricated Zirconia post) and the type of cement used (GIC, self-adhesive resin cement) on the bond strength between the posts and root dentin by using push-out test. Material and methods: Forty eight mandibular premolars extracted for orthodontic reasons (single rooted) were instrumented with ProTaper system (hand use) and obturated with gutta percha for ProTaper using AH26® root canal sealer following the manufacturer instructions. After 24 hours, post space was prepared using Zirix and Glassix drills no.3 creating 8 mm depth post space. The prepared samples were randomly divided into three main groups (16 samples each) according to the type of post used (Group A. Manually Milled Zirconia post, Group B. Prefabricated Fiber post and Group C. Prefabricated Zirconia post) .each group was subdivided into two subgroups (each subgroup contains 8 samples) according to the type of cement used (subgroup A1.Manually Milled Zirconia post cemented with GIC, subgroup A2.Manually Milled Zirconia post cemented with Speed cem),( subgroup B1.Prefabricated Fiber post cemented with GIC, Group B2. Prefabricated Fiber post cemented with Speed cem) and (subgroup C1.Prefabricated Zirconia post cemented with GIC, subgroup C2. Prefabricated Zirconia post cemented with Speed cem), after cementation and incubation for 24hrs, at 37°c and 100% humidity. Each root was sectioned horizontally into 3 slices (2 mm in thickness) representing the coronal, middle and apical regions of the post space. Push out bond strength test was performed and measured using a universal testing machine (Tinius-Olsen) at across head speed of 0.5 mm/min. Results: The results showed that regarding the root region, the bond strength values increased significantly from apical to coronal region for all types of posts in both tested cements. For the effect of post type, the manually Milled Zirconia post cemented with the self-cured resin cement (Speed cem) showed higher bond strength values. For type of cement, the self-adhesive resin cement (Speed cem) showed higher bond strength values. Conclusions: the retention of post restoration was affected by root region, type of post and type of cement used.
The development of new building materials, able of absorbing more energy is an active research area. Engineering Cementitious Composite (ECC) is a class of super-elastic fiberreinforced cement composites characterized by high ductility and tight crack width control. The use of bendable concrete produced from Portland Limestone Cement (PLC) may lead to an interest in new concrete mixes. Impact results of bendable concrete reinforced with steel mesh and polymer fibers will provide data for the use of this concrete in areas subject to impact loading. The experimental part consisted of compressive strength and impact resistance tests along with a result comparison with unreinforced concrete. Concrete samples, with dimensions of 100×
... Show MoreBackground: Multiple sclerosis is a chronic heterogeneous demyelinating axonal and inflammatory disease involving the Central Nervous System [CNS] white matter with a possibility of gray matter involvement in which the insulating covers of nerve cells in the brain and spinal cord are damaged. This damage disrupts the ability of parts of the nervous system to communicate, resulting in a wide range of signs and symptoms. Cerebral venous insufficiency theory was raised as a possible etiology for the disease at 2008 by Zamboni an Italian cardiothoracic surgeon. This theory was defeated by Multiple Sclerosis[ MS] researchers and scientists who thought that the disease is an autoimmune rather than vascular.
Obj
... Show MoreThis research presents experimental and theoretical investigation of 15 reinforced concrete spliced and nonspliced girder models. Splices of hooked dowels and cast in place joints, with or without strengthening steel plates were used. Post-tensioning had been used to enhance the splice strength for some spliced girders. The ANSYS computer program was used for analyzing the spliced and non-spliced girders. A nonlinear three dimensional element was used to represent all test girders. The experimental results have shown that for a single span girder using steel plate connectors in the splice zone has given a sufficient continuity to resist flexural stresses in this region. The experimental results have shown that the deflection of hooked do
... Show MoreThis paper is devoted to investigate the effect of internal curing technique on the properties of self-compacting concrete (SCC). In this study, SCC is produced by using silica fume (SF) as partial replacement by weight of cement with percentage of (5%), sand is partially replaced by volume with saturated fine lightweight aggregate (LWA) which is thermostone chips as internal curing material in three percentages of (5%, 10% and 15%) for SCC, two external curing conditions water and air. The experimental work was divided into three parts: in the first part, the workability tests of fresh SCC were conducted. The second part included conducting compressive strength test and modulus of rupture test at ages of (7, 28 and 90). The third part i
... Show MoreIn this study, Zinc oxide nanostructures were synthesized via a hydrothermal method by using zinc nitrate hexahydrate and sodium hydroxide as a precursor. Three different annealing temperatures were used to study their effect on ZnO NSs properties. The synthesized nanostructure was characterized by X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), Atomic force microscope (AFM), and Fourier Transform Infrared Spectroscopy (FTIR). Their optical properties were studied by using UV -visible spectroscopy. The XRD analysis confirms that all ZnO nanostructures have the hexagonal wurtzite structure with average crystallite size within the range of (30.59 - 34
... Show MoreBackground: Quality of life in brain tumor patients is an emerging issue and has prompted neurosurgeons to recon¬sider the need for cognitive assessment in the course of treatment. To date there has been a lack of comprehensive neuropsychological assessment performed preoperatively and in the acute postoperative period in our hospitals.Objectives: to establish the effects of tumors and their surgical treatment, from a neuropsychological perspective, on cognitive functioning in patients with cerebral Gliomas. Methods: This is a prospective study conducted in the Neurosurgical Hospital in Baghdad, Iraq, during the period from January 1999 to January 2001. Any patient admitted during the period of the study with clinical history, signs, sy
... Show MoreBackground : Hyperglycosylated hCG a newly discovered variant of hCG which can be used as a predictor of invasion of trophoblastic cells in patient with gestational trophoblastic disease. Objectives : To measure hyperglycosylated human chorionic gonadotrophin and to assess how far it can be used as predictor of invasion in invasive mole and choriocarcinoma. Study design control study. Setting: : Case Gynecological department in Baghdad Teaching Hospital from January 2016 to January 2017. Patient and Methods : 60 women were enrolled in this study 30 of them were with gestational trophoblastic disease (no.= 30 ) the remainder were normal pregnancy (no. =30) , hCG –H level was measured in both groups. Results : Mean serum hCG-H le
... Show MoreIn this study, aluminum nanoparticles (Al NPs) were prepared using explosive strips method in double-distilled deionized water (DDDW), where the effect of five different currents (25, 50, 75, 100 and 125 A) on particle size and distribution was studied. Also, the explosive strips method was used to decorate zinc oxide particles with Al particles, where Al particles were prepared in suspended from zinc oxide with DDDW. Transmission electron microscopy (TEM), UV-visible absorption spectroscopy, and x-ray diffraction are used to characterize the nanoparticles. XRD pattern were examined for three samples of aluminum particles and DDDW prepared with three current values (25, 75 and 125 A) and three samples prepared with the same currents for zin
... Show More
