Background: This in vitro study was carried out to investigate the effect of post space regions (coronal, middle and apical), the effect of post types ( Manually Milled Zirconia post, Prefabricated Fiber post, prefabricated Zirconia post) and the type of cement used (GIC, self-adhesive resin cement) on the bond strength between the posts and root dentin by using push-out test. Material and methods: Forty eight mandibular premolars extracted for orthodontic reasons (single rooted) were instrumented with ProTaper system (hand use) and obturated with gutta percha for ProTaper using AH26® root canal sealer following the manufacturer instructions. After 24 hours, post space was prepared using Zirix and Glassix drills no.3 creating 8 mm depth post space. The prepared samples were randomly divided into three main groups (16 samples each) according to the type of post used (Group A. Manually Milled Zirconia post, Group B. Prefabricated Fiber post and Group C. Prefabricated Zirconia post) .each group was subdivided into two subgroups (each subgroup contains 8 samples) according to the type of cement used (subgroup A1.Manually Milled Zirconia post cemented with GIC, subgroup A2.Manually Milled Zirconia post cemented with Speed cem),( subgroup B1.Prefabricated Fiber post cemented with GIC, Group B2. Prefabricated Fiber post cemented with Speed cem) and (subgroup C1.Prefabricated Zirconia post cemented with GIC, subgroup C2. Prefabricated Zirconia post cemented with Speed cem), after cementation and incubation for 24hrs, at 37°c and 100% humidity. Each root was sectioned horizontally into 3 slices (2 mm in thickness) representing the coronal, middle and apical regions of the post space. Push out bond strength test was performed and measured using a universal testing machine (Tinius-Olsen) at across head speed of 0.5 mm/min. Results: The results showed that regarding the root region, the bond strength values increased significantly from apical to coronal region for all types of posts in both tested cements. For the effect of post type, the manually Milled Zirconia post cemented with the self-cured resin cement (Speed cem) showed higher bond strength values. For type of cement, the self-adhesive resin cement (Speed cem) showed higher bond strength values. Conclusions: the retention of post restoration was affected by root region, type of post and type of cement used.
The main idea of this paper is to define other types of a fuzzy local function and study the advantages and differences between them in addition to discussing some definitions of finding new fuzzy topologies. Also in this research, a new type of fuzzy closure has been defined, where the relation between the new type and different types of fuzzy local function has been studied
The aim of this research is to study the effect of welded joint design (Butt joint and lap joint) on thejoint strength during tension and fatigue loading with different current of welding (40,50,60,70,80) ^per, and different type of wire welding. The result of this research is showed that the effect of fatigue loading on the type of joint is more than the effect of tension loading on it. And the butt joint welding is better than the lap joint welding during the fatigue loaded.The experimental results of the effect of W'elding current showed that more increasing and more decreasing the value of the heat input, during the welding was found to produce mechanical brittleness on the buttjoint welding during the static and dynamic loading. Also i
... Show MoreIn this paper, image compression technique is presented based on the Zonal transform method. The DCT, Walsh, and Hadamard transform techniques are also implements. These different transforms are applied on SAR images using Different block size. The effects of implementing these different transforms are investigated. The main shortcoming associated with this radar imagery system is the presence of the speckle noise, which affected the compression results.
This research foxed on the effect of fire flame of different burning temperatures (300, 400 and 500)oC on the compressive strength of reactive powder concrete (RPC).The steady state duration of the burning test was (60)min. Local consuming material were used to mixed a RPC of compressive strength around (100) MPa. The tested specimens were reinforced by (3.0) cm hooked end steel fiber of (1100) MPa yield strength. Three steel fiber volume fraction were adopted in this study (0, 1.0and 1.5)% and two cooling process were included, gradual and sudden. It was concluding that increasing burning temperature decreases the residual compressive strength for RPC specimens of(0%) steel fiber volume fraction by (12.16, 19.46&24.49) and (18.20, 27.77 &3
... Show MoreAbstract
In this work, diabetic glucose concentration level control under disturbing meal has been controlled using two set of advanced controllers. The first set is sliding mode controllers (classical and integral) and the second set is represented by optimal LQR controllers (classical and Min-, ax). Due to their characteristic features of disturbance rejection, both integral sliding mode controller and LQR Minmax controller are dedicated here for comparison. The Bergman minimal mathematical model was used to represent the dynamic behavior of a diabetic patient’s blood glucose concentration to the insulin injection. Simulations based on Matlab/Simulink, were performed to verify the performance of each controll
... Show MoreIn this research, nanofibers have been prepared by using an electrospinning method. Three types of polymer (PVA, VC, PMMA) have been used with different concentration. The applied voltage and the gap length were changed. It was observed that VC is the best polymer than the other types of polymers.
Abstract: In this research, nanofibers have been prepared by using an electrospinning method. Three types of polymer (PVA, VC, PMMA) have been used with different concentration. The applied voltage and the gap length were changed. It was observed that VC is the best polymer than the other types of polymers.
In this work, the effect of aluminum (Al) dust particles on the DC discharge plasma properties in argon was investigated. A magnetron is placed behind the cathode at different pressures and with varying amounts of Al. The plasma temperature (Te) and density (ne) were calculated using the Boltzmann equation and Stark broadening phenomena, which are considered the most important plasma variables through which the other plasma parameters were calculated. The measurements showed that the emission intensity decreases with increasing pressure from 0.06 to 0.4 Torr, and it slightly decreases with the addition of the NPs. The calculations showed that the ne increased and Te decreased with pressure. Both Te and ne were reduced by increasing
... Show MoreThe aim of this study to investigate the microbial load and type of preservative for the types of yogurt available in the Iraqi market to ensure the safety of food provided to the consumer and protect through examining the types of yogurt from harmful bacteria as well as to contain ratios acceptable to yeasts and molds is to find out by comparing models curd careless Iraqi standard quality(ISQ) and see how they conform to these specifications have been collecting 12 brands of yoghurt types it was been (Kala, Activia 1, Activia 2, Mazia, Shelan, Aib, Mersin, Morsi, Al-Safi, Zabady, Zakho, Arbil). Bacteriological tests were conducted on samples of yogurt (total bacterial count, coliform count, counting yeasts and molds). The results showed
... Show More