Preferred Language
Articles
/
jbcd-289
Comparison of regional bond strength among different types of posts luted with different types of cement
...Show More Authors

Background: This in vitro study was carried out to investigate the effect of post space regions (coronal, middle and apical), the effect of post types ( Manually Milled Zirconia post, Prefabricated Fiber post, prefabricated Zirconia post) and the type of cement used (GIC, self-adhesive resin cement) on the bond strength between the posts and root dentin by using push-out test. Material and methods: Forty eight mandibular premolars extracted for orthodontic reasons (single rooted) were instrumented with ProTaper system (hand use) and obturated with gutta percha for ProTaper using AH26® root canal sealer following the manufacturer instructions. After 24 hours, post space was prepared using Zirix and Glassix drills no.3 creating 8 mm depth post space. The prepared samples were randomly divided into three main groups (16 samples each) according to the type of post used (Group A. Manually Milled Zirconia post, Group B. Prefabricated Fiber post and Group C. Prefabricated Zirconia post) .each group was subdivided into two subgroups (each subgroup contains 8 samples) according to the type of cement used (subgroup A1.Manually Milled Zirconia post cemented with GIC, subgroup A2.Manually Milled Zirconia post cemented with Speed cem),( subgroup B1.Prefabricated Fiber post cemented with GIC, Group B2. Prefabricated Fiber post cemented with Speed cem) and (subgroup C1.Prefabricated Zirconia post cemented with GIC, subgroup C2. Prefabricated Zirconia post cemented with Speed cem), after cementation and incubation for 24hrs, at 37°c and 100% humidity. Each root was sectioned horizontally into 3 slices (2 mm in thickness) representing the coronal, middle and apical regions of the post space. Push out bond strength test was performed and measured using a universal testing machine (Tinius-Olsen) at across head speed of 0.5 mm/min. Results: The results showed that regarding the root region, the bond strength values increased significantly from apical to coronal region for all types of posts in both tested cements. For the effect of post type, the manually Milled Zirconia post cemented with the self-cured resin cement (Speed cem) showed higher bond strength values. For type of cement, the self-adhesive resin cement (Speed cem) showed higher bond strength values. Conclusions: the retention of post restoration was affected by root region, type of post and type of cement used.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 01 2011
Journal Name
Journal Of Engineering
TREATMENT OF A HIGH STRENGTH ACIDIC INDUSTRIAL CHEMICAL WASTEWATER USING EXPANDED BED ADSORBER
...Show More Authors

Treatment of a high strength acidic industrial wastewater was attempted by activated carbon
adsorption to evaluate the feasibility of yielding effluents of reusable qualities. The experimental
methods which were employed in this investigation included batch and column studies. The
former was used to evaluate the rate and equilibrium of carbon adsorption, while the latter was
used to determine treatment efficiencies and performance characteristics. Fixed bed and expanded
bed adsorbers were constructed in the column studies. In this study, the adsorption behavior of acetic acid onto activated carbon was examined as a function of the concentration of the adsorbate, contact time and adsorbent dosage. The adsorption data was mo

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jan 19 2021
Journal Name
Sn Applied Sciences
Post-fire serviceability and residual strength of composite post-tensioned concrete T-beams
...Show More Authors
Abstract<p>In this study, the response of ten composite post-tensioned concrete beams topped by a reinforced concrete deck with adequate reinforcing shear connectors is investigated. Depending on the concrete compressive strength of the deck slab (20, 30, and 40 MPa), beams are grouped into three categories. Seven of these beams are exposed to a fire attack of 700 and 800 °C temperature simultaneously with or without the presence of a uniformly distributed sustained static loading. After cooling back to ambient temperature, these composite beams are loaded up to failure, using a force control module, by monotonic static loading in a four-point-bending setup with two symmetrical concentrated loads applied in </p> ... Show More
View Publication Preview PDF
Scopus (8)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Mon Jul 06 2026
Journal Name
Journal Of The College Of Basic Education
Rationing two test in strength endurance for young under the age of 16
...Show More Authors

View Publication
Publication Date
Tue Jan 19 2021
Journal Name
Sn Applied Sciences
Post-fire serviceability and residual strength of composite post-tensioned concrete T-beams
...Show More Authors
Abstract<p>In this study, the response of ten composite post-tensioned concrete beams topped by a reinforced concrete deck with adequate reinforcing shear connectors is investigated. Depending on the concrete compressive strength of the deck slab (20, 30, and 40 MPa), beams are grouped into three categories. Seven of these beams are exposed to a fire attack of 700 and 800 °C temperature simultaneously with or without the presence of a uniformly distributed sustained static loading. After cooling back to ambient temperature, these composite beams are loaded up to failure, using a force control module, by monotonic static loading in a four-point-bending setup with two symmetrical concentrated loads applied in </p> ... Show More
Crossref (7)
Crossref
Publication Date
Mon Jul 06 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The relationship among bite force with facial dimensions and dental arches widths in a sample of Iraqi adults with Class I skeletal and dental relations
...Show More Authors

Background: This study aimed to determine whether there is a relationship among the bite force with facial dimensions and dental arches in a sample of Iraqi adults with Class I skeletal and dental relations. Materials and methods: Forty dental students (20 males and 20 females) were selected under certain criteria. For those individuals, dental impressions, frontal facial photographs and maximum bite force at molar and incisor regions were taken. The dental arches widths and facial dimensions were measured using the AutoCAD program 2007, while the bite force was determined using special device. Descriptive statistics for the measured variables were performed and gender difference was determined using independent sample t-test, while the rel

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 01 2012
Journal Name
Iraqi Journal Of Physics
Comparison study of some mechanical properties of micro and nano silica EP composites
...Show More Authors

The effect of micro-and nano silica particles (silica SiO2 (100 μm), Fused silica (12nm)) on some mechanical properties of epoxy resin was investigated (Young's modulus, Flexural strength). The micro-and nano composites were prepared by using three steps process with different volume fraction of micro-and nano particles (1, 2, 3, 4, 5, 7, 10, 15, and 20 vol. %). Flexural strength and Young's modulus of nano composites were increased at low volume fraction (max. enhancement at 4 vol.% ). However at higher volume fraction both Young's modulus and flexural strength decrease. Moreover, above, the mechanical properties are enhanced more than that of neat epoxy resin. The flexural strength decreases with increasing the volume fraction of micr

... Show More
View Publication Preview PDF
Publication Date
Thu Mar 06 2025
Journal Name
International Journal Of Applied Mechanics And Engineering
Comparison of The Mechanical Properties of Low-Cost Bio Fiber Reinforced Polymer Composites
...Show More Authors

In this study, the physical, and mechanical properties of low-cost and biocomposites were evaluated. The walnut shell and date palm frond fibers were thermally treated in an oven at a temperature of 70°C and then chemically treated with NaOH and distilled water solution, after these treatments, the biocomposite materials will be thermally treated again at 50°C. This procedure was performed for three types of biocomposite; Walnut shell Fiber Reinforced Polymer (WFRP), Date palm Fiber Reinforced Polymer (DFRP), and Hybrid Fiber Reinforced Polymer (HFRP), whereas the biocomposite sheets consisting of 30% biofibers and 70% unsaturated polyester, the mechanical test specimens were cut by a CNC machine according to ASTM standards. The e

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Tue Jul 13 2021
Journal Name
Journal Of Craniofacial Surgery
Comparison of Two Botulinum Toxin Injection Methods for Treatment of Excessive Gingival Display
...Show More Authors

Background: Hyperfunction of the muscles of the upper lip is considered as the most common cause of excessive gingival display (EGD). The aim of this study was to demonstrate the effectiveness of botulinum toxin (BT) injection as a conservative treatment for EGD due to muscular hyperfunction and to compare the outcome of 2 injection methods. Material and methods: This study included 40 participants who were randomly assigned into 2 groups of 20 each, The first group received 2.5IU BT injection at 1 point per side (2-points group), while the second group received a total of 5 IU of BT at 2 points per side (4-points group). The outcome variables were the reduction in the central and lateral gingival display expressed as the difference between

... Show More
View Publication
Scopus (4)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Mon Jul 06 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Salivary C- reactive protein in relation to periodontal health among a group of patients with rheumatoid arthritis in Iraq
...Show More Authors

Background: Rheumatoid arthritis is a chronic destructive inflammatory disease associated with destruction of joint connective tissues and bones, affecting 0.5%–1% of the population worldwide reporting higher prevalence of periodontitis among rheumatoid arthritis patients. The purpose of this study is to estimate level of salivary C-reactive protein in relation to the occurrence and severity of the periodontal disease and other oral parameters among group of patients with rheumatoid arthritis Material and methods: Fifty women patients with rheumatoid arthritis; twenty five on Methotrexate treatment and twenty five on combination treatment of Methotrexate and Etanercept selected as study groups with an age range (30-40) years old and

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 01 2023
Journal Name
Diyala Journal For Veterinary Sciences
Evaluate the Seroprevalence of Human Papillomavirus Immunoglobulin IgM among Women and Its Relationship with Cervical Cancer In Diyala Governorate
...Show More Authors

Background: Prolonged infections caused by High-risk HPVs have the potential to cause cancer in the regions of the body where they infect cells, including the cervix or the oropharynx, which refers to the rear part of the throat. Aims: To detection of Human Papillomavirus (HPV) -IgM , IL-10 and TNF among Iraqi women Methods: A total of 89 blood sample were collected from females with various cervical lesions and 40 blood samples were collected from apparently healthy along with a control group of 40 healthy females. The presence of Human Papillomavirus (HPV) -IgM, IL-10 and TNF in the collected samples was assessed using the ELISA technique. Results: The positivity rate of HPV IgM was 13.5%. This positivity was higher among individuals age

... Show More
View Publication Preview PDF